![IBM P 615 series Скачать руководство пользователя страница 91](http://html1.mh-extra.com/html/ibm/p-615-series/p-615-series_service-manual_4190796091.webp)
Step
1240-3
1.
Turn
off
the
power.
Remove
the
power
cord.
2.
Move
the
quad
of
DIMMs
located
on
the
card
to
the
other
quad’s
slots.
3.
Reattach
the
power
cord.
Wait
for
OK
in
the
operator
panel.
4.
Turn
on
the
power.
Attempt
to
boot
to
the
SMS
menus.
(The
system
may
stop
with
an
8-digit
error
code
before
it
reaches
the
SMS
menus.)
5.
Power
down
the
system
using
the
white
button.
After
the
OK
appears
in
the
operator
panel,
look
at
the
memory
configuration/deconfiguration
menu.
Are
any
DIMMs
deconfigured
or
does
the
error
code
recorded
in
“Step
1240-1”
on
page
70
still
appear?
NO
Go
to
“Step
1240-4.”
YES
Replace
the
system
planar.
Enable
memory
repeat
gard
if
necessary.
Go
to
″
MAP
0410:
Repair
Checkout
″
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems
.
Step
1240-4
The
failing
DIMM(s)
is
in
the
quad
of
DIMMs
that
was
removed
in
“Step
1240-2”
on
page
70.
Do
the
following:
1.
Turn
off
the
power.
Remove
the
power
cord.
2.
Remove
the
quad
of
DIMMs
that
is
on
the
system
planar
and
reinstall
the
quad
of
DIMMs
that
had
been
removed.
The
DIMMs
can
be
reinstalled
in
either
quad.
3.
Go
to
“Step
1240-6”
on
page
72.
Step
1240-5
1.
Turn
off
the
power.
Remove
the
power
cord.
2.
Move
the
quad
of
DIMMs
that
is
on
the
system
planar
to
the
other
quad’s
location.
3.
Reattach
the
power
cord.
Wait
for
OK
in
the
operator
panel.
4.
Turn
on
the
power.
Attempt
to
boot
to
the
SMS
menus.
(The
system
may
stop
with
an
8-digit
error
code
before
it
reaches
the
SMS
menus.)
5.
Power
down
the
system
using
the
white
button.
After
the
OK
appears
in
the
operator
panel,
look
at
the
memory
configuration/deconfiguration
menu.
Are
any
DIMMs
deconfigured
or
does
the
error
code
recorded
in
“Step
1240-1”
on
page
70
still
appear?
NO
Replace
the
system
planar.
Enable
memory
repeat
gard
if
necessary.
Go
to
″
MAP
0410:
Repair
Checkout
″
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems
.
YES
One
or
more
of
the
DIMMs
on
the
card
is
defective.
Go
to
“Step
1240-6”
on
page
72.
Chapter
3.
Maintenance
Analysis
Procedures
(MAPs)
71
Содержание P 615 series
Страница 1: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Страница 2: ......
Страница 3: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Страница 12: ...x EserverpSeries 615 Service Guide...
Страница 16: ...xiv EserverpSeries 615 Service Guide...
Страница 18: ...xvi EserverpSeries 615 Service Guide...
Страница 58: ...38 EserverpSeries 615 Service Guide...
Страница 72: ...52 EserverpSeries 615 Service Guide...
Страница 150: ...130 EserverpSeries 615 Service Guide...
Страница 178: ...158 EserverpSeries 615 Service Guide...
Страница 284: ...264 EserverpSeries 615 Service Guide...
Страница 346: ...5 Start the system as described in Starting the System on page 283 326 EserverpSeries 615 Service Guide...
Страница 384: ...364 EserverpSeries 615 Service Guide...
Страница 385: ...Chapter 10 Parts Information This chapter contains parts information for the pSeries 615 Model 6C3 and Model 6E3 365...
Страница 386: ...System Parts 5 6 7 2 3 1 9 12 10 11 13 14 15 16 18 19 20 8 4 366 EserverpSeries 615 Service Guide...
Страница 388: ...Model 6C3Parts 5 5 7 6 6 2 3 1 4 368 EserverpSeries 615 Service Guide...
Страница 394: ...374 EserverpSeries 615 Service Guide...
Страница 418: ...398 EserverpSeries 615 Service Guide...
Страница 422: ...402 EserverpSeries 615 Service Guide...
Страница 438: ...418 EserverpSeries 615 Service Guide...
Страница 448: ...428 EserverpSeries 615 Service Guide...
Страница 452: ...432 EserverpSeries 615 Service Guide...
Страница 489: ......
Страница 490: ...Printed in U S A October 2003 SA38 0630 02...
Страница 491: ...Spine information pSeries 615 EserverpSeries 615 Service Guide SA38 0630 02...