184
IBM NeXtScale System Planning and Implementation Guide
Table 7-2 Power supply unit table
Table 7-3 System fan status table
Column
Description
Status
Possible values:
Present: Power supply installed
No Present: No power supply installed
Fault: Power supply in faulty condition
Ratings
Display the DC power output rating of the power supply
AC-IN
Display the power AC input voltage rating
EPOW
a
a. For more information about Early Power Off Warning (EPOW) and Throttle, see
3.8, “Power management” on page 52.
Possible values:
Assert: Power supply is in AC lost condition
Normal: Power supply is in healthy, operating condition
Throttle
a
Possible values:
Assert: Power supply is in over-current condition
Normal: Power supply is in healthy, operating condition
DC-PG
Power supply DC power status. Possible values:
No: Power supply is not providing the required DC power
Yes: Power supply is in healthy, operating condition
Column
Description
Status
Possible values:
Present: fan installed
No Present: no fan installed
Type
Possible values:
Low performance
High performance (for future use)