206
IBM NeXtScale System Planning and Implementation Guide
Table 7-8 Power restore policy IPMI commands
Table 7-9 Fan IPMI commands
Description
NetFn
CMD
Data
Get Restore
Policy
0x32
0xa9
Request Data:
Byte 1: Node number LSB (bit mask)
Byte 2: Node number LSB (bit mask)
example: if setting 1,2 and 3 - Byte 1: 0x7 (0000 0111)
Response Data:
Byte 1: Completion code (0x00) or out of range (0xC9)
Set Restore
Policy
0x32
0xaa
Request Data:
None
Response Data:
Byte 1: Completion code (0x00) or out of range (0xC9)
Byte 2: Node number LSB (bit mask)
Byte 3: Node number LSB (bit mask)
Description
NetFn
CMD
Data
Get PSU Fan
status
0x32
0xa5
Request Data:
Byte 1: PSU FAN number (0x01-0x06 FAN 1-6)
Response Data:
Byte 1: Fan speed LSB (rpm)
Byte 2: Fan speed MSB (rpm)
Byte 3: Fan speed (0-100%)
Byte 4: Fan health
0: Not present
1: Abnormal
2: Normal