Removing

 

the

 

blade

 

server

 

from

 

the

 

BladeCenter

 

unit

 

The

 

following

 

illustration

 

shows

 

how

 

to

 

remove

 

an

 

LS22

 

Type

 

7901

 

blade

 

server

 

from

 

a

 

Type

 

8677

 

BladeCenter

 

unit.

 

The

 

procedure

 

for

 

removing

 

the

 

LS42

 

Type

 

7902

 

blade

 

server

 

and

 

MPE

 

is

 

the

 

same.

 

The

 

appearance

 

of

 

your

 

BladeCenter

 

unit

 

might

 

be

 

different.

 

See

 

the

 

documentation

 

for

 

your

 

BladeCenter

 

unit

 

for

 

additional

 

information.

 

  

 

Attention:

   

v

   

To

 

maintain

 

proper

 

system

 

cooling,

 

do

 

not

 

operate

 

the

 

BladeCenter

 

unit

 

without

 

a

 

blade

 

server,

 

expansion

 

unit,

 

or

 

filler

 

installed

 

in

 

each

 

blade

 

bay.

 

v

   

When

 

you

 

remove

 

the

 

blade

 

server,

 

note

 

the

 

bay

 

number.

 

Reinstalling

 

a

 

blade

 

server

 

into

 

a

 

different

 

bay

 

from

 

the

 

one

 

it

 

was

 

removed

 

from

 

might

 

have

 

unintended

 

consequences.

 

Some

 

configuration

 

information

 

and

 

update

 

options

 

are

 

established

 

according

 

to

 

bay

 

number;

 

if

 

you

 

reinstall

 

the

 

blade

 

server

 

into

 

a

 

different

 

bay,

 

you

 

might

 

have

 

to

 

reconfigure

 

the

 

blade

 

server.

To

 

remove

 

the

 

blade

 

server,

 

complete

 

the

 

following

 

steps:

 

1.

   

Read

 

the

 

safety

 

information

 

beginning

 

on

 

page

 

“Safety”

 

on

 

page

 

v

 

and

 

“Installation

 

guidelines”

 

on

 

page

 

17.

 

2.

   

If

 

the

 

blade

 

server

 

is

 

operating,

 

shut

 

down

 

the

 

operating

 

system.

 

3.

   

Press

 

the

 

power-control

 

button

 

(behind

 

the

 

blade

 

server

 

control

 

panel

 

door)

 

to

 

turn

 

off

 

the

 

blade

 

server

 

(see

 

“Turning

 

off

 

the

 

blade

 

server”

 

on

 

page

 

13

 

for

 

more

 

information).

 

 

Attention:

  

Wait

 

at

 

least

 

30

 

seconds,

 

until

 

the

 

hard

 

disk

 

drives

 

stop

 

spinning,

 

before

 

you

 

proceed

 

to

 

the

 

next

 

step.

 

The

 

activity

 

LED

 

on

 

the

 

control

 

panel

 

turns

 

off

 

when

 

the

 

hard

 

disk

 

drive

 

has

 

stopped

 

spinning

 

(see

 

“Blade

 

server

 

control

 

panel

 

and

 

LEDs”

 

on

 

page

 

11).

 

4.

   

Open

 

the

 

two

 

release

 

levers

 

as

 

shown

 

in

 

the

 

illustration.

 

The

 

blade

 

server

 

moves

 

out

 

of

 

the

 

bay

 

approximately

 

0.6

 

cm

 

(0.25

 

inch).

 

5.

   

Pull

 

the

 

blade

 

server

 

out

 

of

 

the

 

bay.

 

6.

   

Put

 

either

 

a

 

blade

 

filler

 

or

 

another

 

blade

 

server

 

in

 

the

 

bay

 

within

 

1

 

minute.

 

Chapter

 

3.

 

Installing

 

optional

 

devices

 

19

Содержание LS42 - BladeCenter - 7902

Страница 1: ......

Страница 2: ......

Страница 3: ...BladeCenter LS22 and LS42 Type 7901 and 7902 Installation and User s Guide...

Страница 4: ...and the Warranty and Support Information document for your blade server type on the IBM Documentation CD Second Edition August 2008 Copyright International Business Machines Corporation 2008 US Gover...

Страница 5: ...assembly 22 Installing a SAS drive tray 23 Removing a SAS drive tray 24 Installing a SAS drive 25 Removing a SAS drive 26 Installing additional memory 27 Installing an additional microprocessor 29 Ins...

Страница 6: ...nostic tools overview 63 ServerGuide problems 64 Appendix Getting help and technical assistance 65 Before you call 65 Using the documentation 65 Getting help and information from the World Wide Web 66...

Страница 7: ...rt eerst de veiligheidsvoorschriften Ennen kuin asennat t m n tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de s curit Vor der Installation dies...

Страница 8: ...r statement with translated versions of the caution or danger statement in the Safety Information document For example if a caution statement is labeled Statement 1 translations for that caution state...

Страница 9: ...quipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instruc...

Страница 10: ...de if not properly used handled or disposed of Do not v Throw or immerse into water v Heat to more than 100 C 212 F v Repair or disassemble Dispose of the battery as required by local ordinances or re...

Страница 11: ...nsion card on page 42 If the expansion card bracket does not have to be installed save it in a safe place The blade server comes with a limited warranty For information about the terms of the warranty...

Страница 12: ...r and on a label on the side of the blade server that is visible when the blade server is not in the BladeCenter unit The LS22 Type 7901 single width blade server requires only one blade bay in the Bl...

Страница 13: ...nd how to configure the blade server The following documentation also comes with the blade server v Problem Determination and Service Guide This document is in Portable Document Format PDF on the IBM...

Страница 14: ...d software requirements The IBM Documentation CD contains documentation for your blade server in Portable Document Format PDF and includes the IBM Documentation Browser to help you find information qu...

Страница 15: ...rs are listed in order of the most occurrences Click a document to view it and press Crtl F to use the Acrobat search function or press Alt F to use the xpdf search function within the document Click...

Страница 16: ...telligent Platform Management Interface IPMI firmware 1 5 compliant v ATI RN 50 video controller v LSI 1064E Serial Attached SCSI SAS controller v Light path diagnostics v Dynamic System Analysis DSA...

Страница 17: ...hardware devices and provides the correct configuration programs and device drivers For more information about the ServerGuide Setup and Installation CD see Using the ServerGuide Setup and Installatio...

Страница 18: ...itor the power environment by using the management module For more information about configuring and using power throttling see the management module documentation or go to http www ibm com bladecente...

Страница 19: ...Ware For a complete list of operating systems that support IBM Director see the IBM Director Compatibility document This document is in Portable Document Format PDF at http www ibm com systems managem...

Страница 20: ...ve the blade server from the BladeCenter unit and remove the cover to see the components For the LS42 Type 7902 blade server you must remove the MPE unit to see the components on the blade server syst...

Страница 21: ...select button Press this button to associate the shared BladeCenter unit keyboard video and mouse port KVM with the blade server The LED on this button flashes while the request is being processed and...

Страница 22: ...ement module Web interface to determine whether local control has been disabled on the blade server Note The operating system in the blade server must provide USB support for the blade server to recog...

Страница 23: ...ough the management module to do so v You can turn on the blade server remotely by using the management module v If the blade server is connected to power the power on LED is flashing slowly and the W...

Страница 24: ...r For additional information see the IBM BladeCenter Management Module User s Guide Blade server connectors The following illustration shows the system board components including connectors for user i...

Страница 25: ...The following illustration shows the MPE components including connectors for user installable optional devices Chapter 2 Power controls and indicators 15...

Страница 26: ...16 BladeCenter LS22 and LS42 Type 7901 and 7902 Installation and User s Guide...

Страница 27: ...2 and click Go Download and install the latest firmware for the management module installed in your BladeCenter unit see the documentation for your management module v Observe good housekeeping in the...

Страница 28: ...ou are ready to install them To reduce the possibility of damage from electrostatic discharge observe the following precautions v Limit your movement Movement can cause static electricity to build up...

Страница 29: ...lade server into a different bay you might have to reconfigure the blade server To remove the blade server complete the following steps 1 Read the safety information beginning on page Safety on page v...

Страница 30: ...on page 17 2 If the blade server is installed in a BladeCenter unit remove it see Removing the blade server from the BladeCenter unit on page 19 for instructions 3 Carefully lay the blade server down...

Страница 31: ...the blade server cover see Opening the blade server cover on page 20 for instructions 3 If the expansion unit has an extraction device such as a thumbscrew or a lever use it to disengage the expansion...

Страница 32: ...over on page 20 for instructions 3 If you are removing the bezel assembly from the blade server and an MPE unit or an expansion unit is connected to the blade server remove the expansion unit see Remo...

Страница 33: ...m the BladeCenter unit on page 19 for instructions 3 Carefully lay the blade server on a flat static protective surface 4 Open the blade server cover see Opening the blade server cover on page 20 for...

Страница 34: ...nes on page 17 2 Carefully lay the blade server on a flat static protective surface 3 Open the blade server cover see Opening the blade server cover on page 20 for instructions 4 If an MPE unit or an...

Страница 35: ...ng the blade server from the BladeCenter unit on page 19 for instructions 3 Carefully lay the blade server on a flat static protective surface 4 Open the blade server cover see Opening the blade serve...

Страница 36: ...expansion unit is connected to the blade server remove the device see Removing an expansion unit on page 21 4 Press the release lever away from the SAS drive then remove the SAS drive Note Press the r...

Страница 37: ...le for the blade server are 1 GB 2 GB and 4 GB v All DIMMs must be installed in pairs of the same size speed type technology and physical design You can use compatible DIMMs from different manufacture...

Страница 38: ...open or close them v Grasp the DIMM gently when you remove it from the connector to avoid ejecting it To install a DIMM complete the following steps 1 Read the safety information that begins on page S...

Страница 39: ...e connector using the retaining clip slots as guides to align the DIMM with the connector g Simultaneously press down firmly and evenly on both ends of the DIMM until it is completely seated in the co...

Страница 40: ...el of BIOS code see Firmware updates on page 59 v The microprocessors terminate themselves therefore no terminator card is required if microprocessor socket 2 is empty on the blade server or on the MP...

Страница 41: ...he system board v Hold the edges of the microprocessor Do not touch the contacts on the microprocessor or the contacts on the microprocessor socket Touching these contacts might result in permanent da...

Страница 42: ...ink becomes contaminated contact your service technician a Remove the plastic protective cover from the bottom of the heat sink b Make sure that the thermal material is still on the bottom of the heat...

Страница 43: ...lat static protective surface 4 Open the blade server cover see Opening the blade server cover on page 20 for instructions 5 If you are installing a standard form factor expansion card in the blade se...

Страница 44: ...Center unit on page 19 for instructions 3 Carefully lay the blade server on a flat static protective surface 4 Open the blade server cover see Opening the blade server cover on page 20 for instruction...

Страница 45: ...c protective surface 4 Open the blade server cover see Opening the blade server cover on page 20 for instructions 5 If you are removing a standard form factor expansion card from the blade server and...

Страница 46: ...connector then slide the slots at the back end of the card out of the expansion card standoffs and lift the card out of the blade server 7 If you have other options to install or remove do so now othe...

Страница 47: ...ade server to remove it from the card retainer brackets 6 Remove the CFFv card The following illustration shows how to remove a CFFv expansion card from the blade server removing a combination form fa...

Страница 48: ...expansion unit is attached to the blade server remove the device see Removing an expansion unit on page 21 6 If a standard form factor expansion card is installed remove it see Removing a standard fo...

Страница 49: ...factor combination form factor or high speed expansion card If the blade server has an MPE installed a high speed expansion card can be installed only in the MPE unit See http www ibm com servers ese...

Страница 50: ...sion unit I O expansion connector expansion unit I O expansion connector blade server cKVM blade server SAS drive 0 blade server SAS drive 1 blade server HSDC standard form factor expansion card X X H...

Страница 51: ...ansion card in the blade server and an expansion unit is installed remove the expansion unit see Removing an expansion unit on page 21 6 Touch the static protective package that contains the expansion...

Страница 52: ...6 c If a drive tray is installed in front of SAS connector 1 remove the drive tray see Removing a SAS drive tray on page 24 Save the screws and the drive tray in a safe place d Install the expansion c...

Страница 53: ...n be installed in an MPE unit that is attached to the blade server You cannot install a high speed expansion card in a blade server to which an expansion unit will be connected If you are installing a...

Страница 54: ...tic protective surface 4 Open the cover see Opening the blade server cover on page 20 for instructions 5 Install the CFFv card The following illustration shows how to install a CFFv expansion card int...

Страница 55: ...rface 4 Open the cover see Opening the blade server cover on page 20 for instructions 5 If you are installing the cKVM card in the blade server and an expansion unit is installed remove the expansion...

Страница 56: ...unit from a double width type of blade server reinstall the expansion unit see Installing an expansion unit on page 48 3 Close the blade server cover see Closing the blade server cover on page 49 If...

Страница 57: ...gins on page Safety on page v and Installation guidelines on page 17 2 If you are installing the bezel assembly on a blade server connect the control panel cable to the control panel connector on the...

Страница 58: ...y pulling the cover off the connector see Blade server connectors on page 14 5 If you are installing a new expansion unit touch the static protective package that contains the expansion unit to any un...

Страница 59: ...ver cover complete the following steps 1 Read the safety information that begins on page Safety on page v and Installation guidelines on page 17 2 If you removed the bezel assembly install it see Inst...

Страница 60: ...de server 3 Select the bay for the blade server An additional bay is required for each blade expansion device that is connected to the blade server Note v When any blade server or device is in blade b...

Страница 61: ...Center T unit only For detailed instructions for reinstalling the bezel assembly see the Installation and User s Guide that comes with the BladeCenter T unit If this is the initial installation for th...

Страница 62: ...nd the keyboard video mouse select button See Blade server control panel and LEDs on page 11 for information about these buttons and their functions The Ethernet controller on the blade server communi...

Страница 63: ...of the BIOS code in the blade server Use it to select the boot protocol and other boot options and to select a power management option For information about using this utility program see Using the PX...

Страница 64: ...s choice to view the machine type and model of the blade server the serial number and the revision level or issue date of the BIOS and diagnostics code that are stored in electrically erasable program...

Страница 65: ...ord when the blade server starts v Advanced Setup Select this choice to change settings for advanced hardware features Important The blade server might malfunction if these settings are incorrectly co...

Страница 66: ...assword override switch see the Problem Determination and Service Guide on the Documentation CD for instructions Using the ServerGuide Setup and Installation CD The ServerGuide Setup and Installation...

Страница 67: ...s updated device drivers for most adapters and devices v Provides diskette free installation for supported Windows operating systems v Includes an online readme file with links to tips for the hardwar...

Страница 68: ...rol to complete the installation The BladeCenter CD drive must be associated with the blade server before you perform this step Installing the operating system without ServerGuide If you have already...

Страница 69: ...the Ethernet controller For device drivers and information about configuring the Ethernet controller see the Broadcom NetXtreme Gigabit Ethernet Software CD that comes with the blade server To find up...

Страница 70: ...ility program to perform the following tasks v Set the SAS device scan order v Set the SAS ID for the controller v Manage the SAS RAID configuration To start the LSI Logic Configuration Utility progra...

Страница 71: ...systems such as Red Hat Linux 7 3 enable you to select the type of mouse that is being used If you are offered this choice select USB instead of PS 2 Although the mouse might be a PS 2 style device co...

Страница 72: ...t you plan to install see http www ibm com systems management Downloading operating system installation instructions You can download operating system installation instructions from the IBM Web site T...

Страница 73: ...ols are available to help you diagnose and solve hardware related problems v POST beep codes The power on self test beep codes can indicate the detection of a problem One beep indicates successful com...

Страница 74: ...uide Setup and Installation CD on page 56 3 If the startup boot sequence settings have been changed make sure that the CD or DVD drive is first in the startup sequence in the Configuration Setup Utili...

Страница 75: ...by following the troubleshooting procedures that IBM provides in the online help or in the documentation that is provided with your IBM product The documentation that comes with IBM systems also descr...

Страница 76: ...ion see http www ibm com services sl products For more information about Support Line and other IBM services see http www ibm com services or see http www ibm com planetwide for support telephone numb...

Страница 77: ...FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could incl...

Страница 78: ...rks of others Important notes Processor speed indicates the internal clock speed of the microprocessor other factors also affect application performance CD or DVD drive speed is the variable read rate...

Страница 79: ...g a de la informaci n TI que reciclen responsablemente sus equipos cuando stos ya no les sean tiles IBM dispone de una serie de programas y servicios de devoluci n de productos en varios pa ses a fin...

Страница 80: ...metal hydride lithium or lithium ion battery Consult your user manual or service manual for specific battery information The battery must be recycled or disposed of properly recycling facilities may...

Страница 81: ...l symbol for the metal concerned in the battery Pb for lead Hg for mercury and Cd for cadmium Users of batteries and accumulators must not dispose of batteries and accumulators as unsorted municipal w...

Страница 82: ...and 2 this device must accept any interference received including interference that may cause undesired operation Industry Canada Class A emission compliance statement This Class A digital apparatus...

Страница 83: ...environment this product may cause radio interference in which case the user may be required to take adequate measures European Community contact IBM Technical Regulations Pascalstr 100 Stuttgart Ger...

Страница 84: ...Korean Class A Warning Statement 74 BladeCenter LS22 and LS42 Type 7901 and 7902 Installation and User s Guide...

Страница 85: ...your blade server 53 connectors I O expansion card 14 input output 52 memory 14 microprocessor 14 MPE board 14 SAS hard disk drives 14 system board 14 controller enable or disable Ethernet 54 enable o...

Страница 86: ...tility program description 53 M major components MPE 10 system board 10 media tray select button 12 memory specifications 6 memory module installing 27 order of installation 27 specifications 6 8 supp...

Страница 87: ...CD 7 setup with ServerGuide 57 small form factor expansion card installing 41 small form factor expansion card removing 34 software service and support 66 specifications BladeCenter LS22 and LS42 6 st...

Страница 88: ...78 BladeCenter LS22 and LS42 Type 7901 and 7902 Installation and User s Guide...

Страница 89: ......

Страница 90: ...Part Number 44R5057 Printed in USA 1P P N 44R5057...

Отзывы: