Installing the storage expansion enclosure in the rack cabinet
To install the storage expansion enclosure, complete the following steps.
Note:
For more information about how to use a lift tool, see the documentation that came with the lift
tool.
1.
Prepare the storage expansion enclosure for installation:
a.
Position the lift tool so that it is facing one side of the shipping box.
b.
Remove the foam shipping material from the sides and ends of the storage expansion enclosure.
c.
If necessary, cut away sides of the shipping box so that the lift tool has access to the storage
expansion enclosure.
d.
Open the plastic bag and tuck it under the storage expansion enclosure. The plastic bag reduces
friction and makes it easier to slide the unit off of the shipping box onto the lift tool, and off of the
lift tool and into the rack cabinet.
e.
Install the four handles on the sides of the storage expansion enclosure. See “Installing and
removing the handles” on page 9 for detailed instructions.
56.7 kg (125 lbs)
102 kg (225 lbs)
(12 x 5)
(60X)
Attention:
a.
Because of the size and weight of the storage expansion enclosure as shipped, a lift tool and a
minimum of two trained service technicians are required to push the enclosure out of its
custom-designed package and onto the lift tool. If a lift tool is not available, see Appendix G,
“Component weights”, in the
IBM System Storage EXP5060 Storage Subsystem Installation, User’s, and
Maintenance Guide
for additional information.
b.
Before you move or relocate a rack that contains EXP5060 storage expansion enclosures, see
“Relocating a populated rack” in the
IBM System Storage EXP5060 Storage Subsystem Installation,
User’s, and Maintenance Guide
for additional information.
2.
With the help of a lift tool and a minimum of two trained service technicians, or a lift tool and
professional movers, slide the storage expansion enclosure off of the side of the shipping box and
onto the lift tool. Align it in front of the rack.
3.
Put the rear edge of the storage expansion enclosure on the support rails.
4.
Remove the two handles (one on each side) at the rear of the storage expansion enclosure. Do not
remove the front handles on the sides of the unit.
5.
Slide the storage expansion enclosure halfway into the rack. Remove the remaining two handles at the
front of the unit.
10