88
IBM xSeries 130: User’s Reference
POST error messages
The following tables provide information about the POST error messages that can
appear during startup. You need to attach a mouse, monitor, and keyboard to view
the post error messages.
Table 14. POST error messages.
POST message
Description
062
The appliance server failed to start on three consecutive attempts.
All caches are disabled. Repeatedly turning the appliance server on and then off or resetting the
appliance server might cause this problem.
Action:
Start the Configuration/Setup Utility program and verify that all settings are correct. Use
the
Cache Control
selection in the Advanced Setup menu of the Configuration/Setup
Utility program to enable the caches.
If the problem persists, call for service. When the problem is corrected, be sure to enable the
caches.
101 102 106
An error occurred during the system board and microprocessor test.
Action:
Call for service.
114
An adapter read-only memory (ROM) error occurred.
Action:
Remove the options. If you can start the appliance server without the options installed,
reinstall each option one at a time and retest after each is reinstalled. When an option
fails, replace it.
If you cannot isolate and correct the problem, call for service.
129
An error was detected in the L1 cache of one of the microprocessors.
Action:
1.
If you just installed a microprocessor, verify that the microprocessor is installed and
seated correctly.
2.
If the problem persists, call for service.
151
A real-time clock (RTC) error occurred.
Action:
Call for service.
161
The real-time clock battery has failed.
Action:
Replace the battery yourself or call for service.
You can use the appliance server until you replace the battery. However, you must run the
Configuration/Setup Utility program and set the time and date and other custom settings each
time you turn on the appliance server.
162
A change in device configuration occurred. This error occurs under one or more of the following
conditions:
•
A new device has been installed.
•
A device has been moved to a different location or cable connection.
•
A device has been removed or disconnected from a cable.
•
A device is failing and is no longer recognized by the appliance server as being installed.
•
An external device is not turned on.
•
An invalid checksum is detected in the battery-backed memory.
Action:
Verify that all external devices are turned on. You must turn on external devices before
turning on the appliance server.
If you did not add, remove, or change the location of a device, a device is probably failing.
Running the diagnostic program might isolate the failing device.
If you cannot isolate and correct the problem, call for service.
Содержание eServer 130 xSeries
Страница 1: ...User s Reference xSeries 130 ...
Страница 2: ......
Страница 3: ...IBM IBM xSeries 130 User s Reference ...
Страница 8: ...vi IBM xSeries 130 User s Reference ...
Страница 14: ...xii IBM xSeries 130 User s Reference ...
Страница 46: ...32 IBM xSeries 130 User s Reference ...
Страница 58: ...44 IBM xSeries 130 User s Reference ...
Страница 62: ...48 IBM xSeries 130 User s Reference ...
Страница 96: ...82 IBM xSeries 130 User s Reference ...
Страница 136: ...122 IBM xSeries 130 User s Reference ...
Страница 154: ...140 IBM xSeries 130 User s Reference ...
Страница 155: ......
Страница 156: ...IBM Part Number 32P0093 Printed in U S A 32P 93 ...