Table 20. Drive LED activity (continued)
LED
LED state
Descriptions
Activity and
Fault LEDs
All unlit
Check for and resolve one of the following situations:
v
EXP395 is turned off.
v
EXP395 enclosure speed is not set correctly.
Activity LED
Flashing once
every 2
seconds
Check for and resolve one of the following situations:
v
EXP395 is not connected to the DS3950 storage
subsystem.
v
DS3950 storage subsystem controller firmware is not at
the required level to support the drive.
v
Drives are part of an exported array. Once the array is
exported, the drives in the array are spun down in
preparation for being removed from the enclosure.
v
Drives are not compatible. Incompatible drives are spun
down when they are inserted into the drive slots.
v
Drives are failed by the storage subsystem controllers.
Activity and
Fault LEDs
Flashing
together in a
certain pattern
Drive failure due to the incorrect EXP395 enclosure speed
setting or internal drive hardware failures.
v
Fibre-channel loop IDs:
When you install an E-DDM in the storage expansion
enclosure, the drive tray connects into a printed circuit board called the
midplane
.
The midplane sets the fibre-channel loop ID automatically, based on the setting
of the enclosure ID and the physical location (bay) of the E-DDM FRU.
v
Hot-swap hardware:
The EXP395 contains hardware that enables you to replace
a failed E-DDM without turning off the storage expansion enclosure. You can
continue to operate your system while an E-DDM is removed or installed. These
E-DDMs are known as hot-swap E-DDMs.
Installing hot-swap hard disk drives
With the exception of the DS3950 storage subsystem initial power on, IBM
recommends that you add E-DDMs while the storage expansion enclosure is
turned on and running. Complete the following steps to install hot-swap E-DDMs
in the storage expansion enclosure:
Attention:
After you remove a E-DDM FRU, wait 70 seconds before replacing or
reseating it to allow it to properly spin down. Failure to do so may cause
undesired events.
Before you begin, ensure that you wear an anti-static wrist strap.
1.
Read the documentation that comes with the E-DDM.
2.
Check for Fault LEDs shown in Figure 34 on page 71. If any amber LEDs are
lit, see “Solving problems” on page 93.
70
IBM System Storage DS3950 EXP395 Storage Expansion Enclosure: Installation, User’s, and Maintenance Guide
Содержание DS3950
Страница 44: ...20 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 88: ...64 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 116: ...92 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 128: ...104 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 136: ...112 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 144: ...120 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 148: ...124 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 160: ...136 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 180: ...156 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 184: ...160 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 185: ......
Страница 186: ...Part Number 46W6896 Printed in USA GA32 0956 04 1P P N 46W6896...