3.
With the SFP latch in the unlocked position, extract the SFP module.
v
For SFP modules that contain plastic tabs, slide the SFP module out of the
port.
v
For SFP modules that contain wire tabs, grasp the wire latch and pull the
SFP module out of the mini-hub port.
4.
Replace the protective cap on the SFP module.
5.
Place the SFP module into a static-protective package.
6.
Replace the protective cap on the host port.
Handling fibre-optic cables
Note:
IBM Fibre Channel (FC) cable options have been tested and approved for
the IBM DS storage products. For optimal performance and compatibility,
always use IBM FC cable options when installing the IBM DS products.
Attention:
To avoid damage to your fibre-optic cables, follow these guidelines:
v
For devices on slide rails, leave enough slack in the cables so they do
not
bend
to a diameter of less than 76 mm (3 in.), or a radius less than 38 mm (1.5 in.),
when extended or become pinched when retracted.
v
Do not overtighten the cable straps or bend the cables to a diameter of less than
76 mm (3 in.), or a radius less than 38 mm (1.5 in.).
v
When storing excess or unused fibre-optic cables, do not bend the cables to a
diameter of less than 76 mm (3 in.), or a radius less than 38 mm (1.5 in.) or wrap
them around themselves. See Figure 19 on page 37.
v
Loop diameter of 76 mm (3 in.) and bend radius of 38 mm (1.5 in.) for fibre
optic cable are IBM DS storage subsystem recommended minimums. Loops or
bends smaller than this recommendation may cause damage to your fibre optic
cables. It is best practice to use loop diameters and bend radii that are greater
than these recommended minimums.
v
Do not route the cable along a folding cable-management arm.
v
Route the cable away from places where it can be damaged by other devices in
the rack cabinet.
v
Do not put excess weight on the cable at the connection point. Be sure that the
cable is well supported.
v
Do not use plastic cable ties in place of the provided cable straps.
v
The following are the supported maximum cable lengths:
– 1 Gbps: 500 meters 50/125 um fibre, 300 meters 62.5/125 um fibre
– 2 Gbps: 300 meters 50/125 um fibre, 150 meters 62.5/125 um fibre
o
Protective
cap
Wire
tab
SFP
module
90
Figure 18. Unlocking the SFP module latch - wire variety
36
IBM System Storage DS3950 EXP395 Storage Expansion Enclosure: Installation, User’s, and Maintenance Guide
Содержание DS3950
Страница 44: ...20 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 88: ...64 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 116: ...92 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 128: ...104 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 136: ...112 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 144: ...120 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 148: ...124 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 160: ...136 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 180: ...156 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 184: ...160 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 185: ......
Страница 186: ...Part Number 46W6896 Printed in USA GA32 0956 04 1P P N 46W6896...