v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing, Types 8014, 8028 and 1916,” on page 25 to determine which components are CRUs
and which components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
00151720
Parity Error Reseat the microprocessor.
Detected on Processor bus.
1.
(Trained service technician only) Reseat the
microprocessor - See “Removing a
microprocessor and heat sink” on page 60 and
“Installing a microprocessor and heat sink” on
page 62.
2.
Replace the following components one at a time,
in the order shown, restarting the blade server
each time:
a.
(Trained service technician only)
Microprocessor - See “Removing a
microprocessor and heat sink” on page 60 and
“Installing a microprocessor and heat sink” on
page 62.
b.
(Trained service technician only)
System-board assembly - See “Removing the
system-board assembly” on page 65 and
“Installing the system-board assembly” on
page 66.
00151730
CRC Error
Reseat all DIMMs - See “Removing a memory
module” on page 44 and “Installing a memory
module” on page 46.
01295085
ECC checking hardware test failed
1.
(Trained service technician only) Reseat the
microprocessor - See “Removing a
microprocessor and heat sink” on page 60 and
“Installing a microprocessor and heat sink” on
page 62.
2.
Replace the following components, one at a time,
in the order shown, restarting the blade server
each time:
a.
(Trained service technician only)
Microprocessor - See “Removing a
microprocessor and heat sink” on page 60 and
“Installing a microprocessor and heat sink” on
page 62.
b.
(Trained service technician only)
System-board assembly - See “Removing the
system-board assembly” on page 65 and
“Installing the system-board assembly” on
page 66.
012980
xx
The BIOS does not support the Processor
P
xx
1.
Make sure that the microprocessor is supported.
2.
Update the blade server firmware. Go to
http://www.ibm.com/systems/support/.
Chapter 6. Diagnostics
111
Содержание BladeCenter HS12 Type 1916
Страница 1: ...BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 36: ...24 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 186: ...174 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 190: ...178 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 198: ...186 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 203: ......
Страница 204: ...Part Number 60Y1601 Printed in USA 1P P N 60Y1601...