The following information is displayed for RAID-1 and RAID-10 arrays:
COMMAND STATUS
Command: OK
stdout: yes
stderr: no
Before command completion, additional instructions may appear below.
Components
Primary
Secondary
Status
hdisk4
degraded
pdisk13
pdisk15
good
pdisk3
pdisk6
good
pdisk7
BlankReserved5Z
degraded
F1=HelpF2=Refresh
F3=Cancel
F6=Command
F8=Image
F9=Shell
F10=Exit
/=Find
n=Find Next
Status data is given for the array and for each mirrored pair of disk drives in the
array. The status values for the array are:
good
The status of all mirrored pairs is good.
exposed
The status of one or more mirrored pairs is exposed. No mirrored pair is
degraded.
degraded
The status of one or more mirrored pairs is degraded.
rebuilding
The status of one or more mirrored pairs is rebuilding. No mirrored pair is
exposed or degraded.
offline
One of the following conditions exists:
v
The status of one or more mirrored pairs is offline.
v
The first two member disk drives of the primary half are missing, and the
Split Array Resolution flag is set to Primary.
v
The first member disk drive of the secondary half is missing, and the
Split Array Resolution flag is set to Secondary.
unknown
Not enough configuration data is available to determine the state of the
array. Under these conditions, ignore the primary and secondary
designations and the array-pair status.
The status values for mirrored pairs are:
good
Both member disk drives of the mirrored pair are present and working.
106
User’s Guide and Maintenance Information
Содержание Advanced SerialRAID Adapters SA33-3285-02
Страница 1: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Страница 2: ......
Страница 3: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Страница 16: ...xiv User s Guide and Maintenance Information ...
Страница 18: ...xvi User s Guide and Maintenance Information ...
Страница 21: ...Part 1 User Information 1 ...
Страница 22: ...2 User s Guide and Maintenance Information ...
Страница 48: ...28 User s Guide and Maintenance Information ...
Страница 64: ...44 User s Guide and Maintenance Information ...
Страница 76: ...56 User s Guide and Maintenance Information ...
Страница 212: ...192 User s Guide and Maintenance Information ...
Страница 228: ...208 User s Guide and Maintenance Information ...
Страница 230: ...210 User s Guide and Maintenance Information ...
Страница 254: ...234 User s Guide and Maintenance Information ...
Страница 274: ...254 User s Guide and Maintenance Information ...
Страница 330: ...310 User s Guide and Maintenance Information ...
Страница 331: ...Part 2 Maintenance Information 311 ...
Страница 332: ...312 User s Guide and Maintenance Information ...
Страница 338: ...318 User s Guide and Maintenance Information ...
Страница 430: ...410 User s Guide and Maintenance Information ...
Страница 503: ...Part 3 Appendixes 483 ...
Страница 504: ...484 User s Guide and Maintenance Information ...
Страница 508: ...488 User s Guide and Maintenance Information ...
Страница 529: ......
Страница 530: ...Part Number 27H0678 Printed in the U S A SA33 3285 02 1P P N 27H0678 ...
Страница 531: ...Spine information Advanced SerialRAID Adapters User s Guide and Maintenance Information ...