For the examples given here, assume that the following items of hardware are available
in the system:
v
A RAID Manager named ssa0
v
Four SSA physical disks named pdisk0, pdisk1, pdisk2, and pdisk3
Example 1: To Create a RAID-0 Array
This example shows how to use three SSA physical disks to create a RAID-0 array. The
attributes of the disks are all set to their default values.
Type the command:
> ssaraid -C -l ssa0 -t raid_0 -s pdisk0 pdisk1 pdisk2 -d
where:
-C
specifies that this operation is a create operation.
-l ssa0
specifies that RAID Manager ssa0 is to be used.
-t raid_0
specifies that a RAID-0 array object is to be created.
-s pdisk...
specifies the free pdisk that is to become the member disk of the new
array.
-d
specifies that a system disk is to be attached to the new array.
Example 2: To Create a RAID-1 Array
This example shows how to use two SSA physical disks to create a RAID-1 array. The
attributes of the disks are all set to their default values.
Type the command:
> ssaraid -C -l ssa0 -t raid_1 -s pdisk0 pdisk1 -d
where:
-C
specifies that this operation is a create operation.
-l ssa0
specifies that RAID Manager ssa0 is to be used.
-t raid_1
specifies that a RAID-1 array object is to be created.
-s pdisk...
specifies the free pdisk that is to become the member disk of the new
array. RAID-1 arrays provide support for only two member disk drives. The first disk
drive that is specified becomes the primary member disk drive.
-d
specifies that a system disk is to be attached to the new array.
Chapter 12. Using the SSA Command Line Interface for RAID Configurations
239
|
|
Содержание Advanced SerialRAID Adapters SA33-3285-02
Страница 1: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Страница 2: ......
Страница 3: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Страница 16: ...xiv User s Guide and Maintenance Information ...
Страница 18: ...xvi User s Guide and Maintenance Information ...
Страница 21: ...Part 1 User Information 1 ...
Страница 22: ...2 User s Guide and Maintenance Information ...
Страница 48: ...28 User s Guide and Maintenance Information ...
Страница 64: ...44 User s Guide and Maintenance Information ...
Страница 76: ...56 User s Guide and Maintenance Information ...
Страница 212: ...192 User s Guide and Maintenance Information ...
Страница 228: ...208 User s Guide and Maintenance Information ...
Страница 230: ...210 User s Guide and Maintenance Information ...
Страница 254: ...234 User s Guide and Maintenance Information ...
Страница 274: ...254 User s Guide and Maintenance Information ...
Страница 330: ...310 User s Guide and Maintenance Information ...
Страница 331: ...Part 2 Maintenance Information 311 ...
Страница 332: ...312 User s Guide and Maintenance Information ...
Страница 338: ...318 User s Guide and Maintenance Information ...
Страница 430: ...410 User s Guide and Maintenance Information ...
Страница 503: ...Part 3 Appendixes 483 ...
Страница 504: ...484 User s Guide and Maintenance Information ...
Страница 508: ...488 User s Guide and Maintenance Information ...
Страница 529: ......
Страница 530: ...Part Number 27H0678 Printed in the U S A SA33 3285 02 1P P N 27H0678 ...
Страница 531: ...Spine information Advanced SerialRAID Adapters User s Guide and Maintenance Information ...