When the rebuilding operation is complete, ask the user to run
diagnostics in System Verification mode to the SSA adapters, to
ensure that the rebuilding operation has not found any more
problems.
k. Go to “MAP 2410: SSA Repair Verification” on page 475 to verify the
repair.
19. (from step 18)
Does the Link Verification service aid indicate an open loop?
NO
Go to step 20.
YES
Go to “MAP 2320: SSA Link” on page 445.
20. (from step 19)
Does any SSA disk drive have its Check light on?
NO
The disk drive might have been removed from the subsystem.
a. Reinstall the removed drive, or select a new disk drive for addition to
the array.
b. Type
smitty ssaraid
and press Enter.
c. Select Change Member Disks in an SSA RAID Array.
d. Select Swap Members of an SSA RAID Array.
e. Select the degraded hdisk.
f. Referring to the displayed instructions, exchange the failed member for
a new disk drive. (The Disk to Remove is listed as BlankReserved;
the Disk to Add is the disk drive that you reinstalled or selected in
step 20a.) When failed disk drives have been exchanged for new disk
drives, the data is rebuilt, and the array changes its state to the Good
state.
g. Go to “MAP 2410: SSA Repair Verification” on page 475 to verify the
repair.
YES
a. Exchange the failed disk drive for a new one (see “Exchanging Disk
Drives” on page 319).
b. Type
smitty ssaraid
and press Enter.
c. Select Change Member Disks in an SSA RAID Array.
d. Select Swap Members of an SSA RAID Array.
e. Select the degraded hdisk.
f. Referring to the displayed instructions, exchange the failed member for
a new disk drive. (The Disk to Remove is listed as BlankReserved;
the Disk to Add is the disk drive that you reinstalled or selected in
step 20a.) When failed disk drives have been exchanged for new disk
drives, the data is rebuilt, and the array changes its state to the Good
state.
g. Go to “MAP 2410: SSA Repair Verification” on page 475 to verify the
repair.
Chapter 18. SSA Problem Determination Procedures
465
Содержание Advanced SerialRAID Adapters SA33-3285-02
Страница 1: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Страница 2: ......
Страница 3: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Страница 16: ...xiv User s Guide and Maintenance Information ...
Страница 18: ...xvi User s Guide and Maintenance Information ...
Страница 21: ...Part 1 User Information 1 ...
Страница 22: ...2 User s Guide and Maintenance Information ...
Страница 48: ...28 User s Guide and Maintenance Information ...
Страница 64: ...44 User s Guide and Maintenance Information ...
Страница 76: ...56 User s Guide and Maintenance Information ...
Страница 212: ...192 User s Guide and Maintenance Information ...
Страница 228: ...208 User s Guide and Maintenance Information ...
Страница 230: ...210 User s Guide and Maintenance Information ...
Страница 254: ...234 User s Guide and Maintenance Information ...
Страница 274: ...254 User s Guide and Maintenance Information ...
Страница 330: ...310 User s Guide and Maintenance Information ...
Страница 331: ...Part 2 Maintenance Information 311 ...
Страница 332: ...312 User s Guide and Maintenance Information ...
Страница 338: ...318 User s Guide and Maintenance Information ...
Страница 430: ...410 User s Guide and Maintenance Information ...
Страница 503: ...Part 3 Appendixes 483 ...
Страница 504: ...484 User s Guide and Maintenance Information ...
Страница 508: ...488 User s Guide and Maintenance Information ...
Страница 529: ......
Страница 530: ...Part Number 27H0678 Printed in the U S A SA33 3285 02 1P P N 27H0678 ...
Страница 531: ...Spine information Advanced SerialRAID Adapters User s Guide and Maintenance Information ...