array copy services (continued)
Prepare a Copy option
175
Uncouple a Volume Group, Logical Volumes, or File
Systems Copy option
177
array states, RAID-0
31
Good
31
Offline
31
array states, RAID-1
32
array states, RAID-10
36
Degraded
37
Exposed
36
Good
36
multiple
38
Offline
37
Rebuilding
37
Unknown
38
array states, RAID-5
33
Degraded
33
Exposed
33
read operations while in
33
write operations while in
33
flowchart
35
Good
33
initial rebuilding operation
34
Offline
34
Rebuilding
34
adapter replacement
34
disk drive replacement
34
arrays
adding a disk drive to an SSA RAID array
140
adding a new hot spare pool
83
adding disks to a hot spare pool
86
adding to the configuration
60
canceling all SSA disk drive identifications
129
changing member disks in an SSA RAID array
137
changing or showing the attributes of an SSA RAID
array
135
changing or showing the status of a hot spare
pool
74
changing or showing the use of an SSA disk
drive
144
changing the use of multiple SSA physical
disks
147
creating a hot spare disk drive
72
deleting an old RAID array recorded in an SSA RAID
manager
133
deleting from the configuration
70
identifying and correcting or removing failed disk
drives
91
identifying array candidate disk drives
125
identifying hot spare disk drives
121
identifying rejected array disk drives
123
identifying system disk drives
127
identifying the disk drives in an SSA RAID array
119
installing a replacement disk drive
95
arrays (continued)
installing and configuring
58
listing all defined SSA RAID arrays
100
listing all SSA RAID arrays that are connected to a
RAID manager
102
listing all supported SSA RAID arrays
101
listing hot spare disk drives
111
listing old RAID arrays recorded in an SSA RAID
manager
131
listing rejected array disk drives
113, 115
listing system disk drives
117
listing the disk drives in an SSA RAID array
109
listing the disks that are in a hot spare pool
80
listing the status of all defined SSA RAID
arrays
104
removing a disk drive from an SSA RAID array
138
removing disks from a hot spare pool
86
showing the disks that are protected by hot
spares
77
swapping members of an SSA RAID array
142
Attention notices
formatting disk drives
389
fragility of disk drives
443
service aids
373
attributes
action
new_member=disk
251
old_member=disk
251
array member disk drives
spare_pool
249
couple action
force=yes/no
252
pool_selection=own/primary/secondary
252
raid_copy=copy
252
disk device driver
270
adapter_a
271
adapter_b
271
connwhere_shad
271
location
271
max_coalesce
271
node_number
270
primary_adapter
271
pvid
271
queue_depth
271
reserve_lock
271
size_in_mb
271
write_queue_mod
272
hot spare disk drives change
spare_pool
249
hot spare pool
minimum_spares
249
ODM, PCI
257
bus_intr_level
257
bus_io_addr
257
bus_mem_start
257
494
User’s Guide and Maintenance Information
Содержание Advanced SerialRAID Adapters SA33-3285-02
Страница 1: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Страница 2: ......
Страница 3: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Страница 16: ...xiv User s Guide and Maintenance Information ...
Страница 18: ...xvi User s Guide and Maintenance Information ...
Страница 21: ...Part 1 User Information 1 ...
Страница 22: ...2 User s Guide and Maintenance Information ...
Страница 48: ...28 User s Guide and Maintenance Information ...
Страница 64: ...44 User s Guide and Maintenance Information ...
Страница 76: ...56 User s Guide and Maintenance Information ...
Страница 212: ...192 User s Guide and Maintenance Information ...
Страница 228: ...208 User s Guide and Maintenance Information ...
Страница 230: ...210 User s Guide and Maintenance Information ...
Страница 254: ...234 User s Guide and Maintenance Information ...
Страница 274: ...254 User s Guide and Maintenance Information ...
Страница 330: ...310 User s Guide and Maintenance Information ...
Страница 331: ...Part 2 Maintenance Information 311 ...
Страница 332: ...312 User s Guide and Maintenance Information ...
Страница 338: ...318 User s Guide and Maintenance Information ...
Страница 430: ...410 User s Guide and Maintenance Information ...
Страница 503: ...Part 3 Appendixes 483 ...
Страница 504: ...484 User s Guide and Maintenance Information ...
Страница 508: ...488 User s Guide and Maintenance Information ...
Страница 529: ......
Страница 530: ...Part Number 27H0678 Printed in the U S A SA33 3285 02 1P P N 27H0678 ...
Страница 531: ...Spine information Advanced SerialRAID Adapters User s Guide and Maintenance Information ...