Table 2. Error Labels (continued)
Error Label
Error ID
Error Description
SSA_LINK_ERROR
ABECECFD
Link errors might be detected by any node in the SSA loop. The
adapter is notified of these errors. It performs any necessary
error recovery, and logs the error. Link errors are normally
associated with some other failure on the SSA loop. Link errors
might be logged when other devices on the loop are switched on
or off, or when cables or devices are disconnected during
service activity. Intermittent link errors are not serious. If many
link errors occur, however, one of the SSA links might be going
to fail. Run error log analysis to determine whether any repair
action is needed.
SSA_LINK_OPEN
625E6B9A
SSA devices are normally configured in a closed loop. The loop
consists of a series of links, each link connecting two SSA
devices. A device can be an adapter card or a disk drive. If this
loop becomes broken, the alternative signal path round the loop
is automatically used. A link might be broken if:
v
A device is removed from the loop
v
A device on the loop is reset or switched off, or it fails
v
An SSA cable is removed, or it fails
Each SSA device has a Ready light that indicates the
operational status of the SSA loop to which that device is
attached. The light is permanently on when the device can
communicate with the two SSA devices that are logically next to
it on the SSA loop. The light flashes if the device can
communicate with only one of those two devices. The light is off
if the device cannot communicate with either of the two SSA
devices. Usually, an SSA device is present at each side of the
point where the SSA loop is broken. Each of those devices has
its Ready light flashing.
SSA_LOGGING_ERROR
610BDA5E
The adapter has passed error log data for a disk drive to the
device driver error logger, but the disk drive to which the data is
related is not configured into the using system. This problem
usually occurs because the disk drive was not available to the
adapter when the cfgmgr command was previously run.
SSA_SETUP_ERROR
48489B00
A user procedure has not been performed correctly. Use the
SRN to determine the procedure that has caused the problem.
SSA_SOFTWARE_ERROR
91FBD5DB
The software has detected an unexpected condition. If you have
just installed the SSA subsystem, ensure that the latest versions
of microcode and software have been installed. If the system is
still operational and you have any hot spare disk drives attached
to the adapter, an automatic dump might have been performed.
Run ssa_getdump -l to see if any dump data is present.
Software errors can result from hardware failures. Always solve
hardware problems, therefore, before looking for software errors.
224
User’s Guide and Maintenance Information
:
:
:|
|
|
|
|
:
Содержание Advanced SerialRAID Adapters SA33-3285-02
Страница 1: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Страница 2: ......
Страница 3: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Страница 16: ...xiv User s Guide and Maintenance Information ...
Страница 18: ...xvi User s Guide and Maintenance Information ...
Страница 21: ...Part 1 User Information 1 ...
Страница 22: ...2 User s Guide and Maintenance Information ...
Страница 48: ...28 User s Guide and Maintenance Information ...
Страница 64: ...44 User s Guide and Maintenance Information ...
Страница 76: ...56 User s Guide and Maintenance Information ...
Страница 212: ...192 User s Guide and Maintenance Information ...
Страница 228: ...208 User s Guide and Maintenance Information ...
Страница 230: ...210 User s Guide and Maintenance Information ...
Страница 254: ...234 User s Guide and Maintenance Information ...
Страница 274: ...254 User s Guide and Maintenance Information ...
Страница 330: ...310 User s Guide and Maintenance Information ...
Страница 331: ...Part 2 Maintenance Information 311 ...
Страница 332: ...312 User s Guide and Maintenance Information ...
Страница 338: ...318 User s Guide and Maintenance Information ...
Страница 430: ...410 User s Guide and Maintenance Information ...
Страница 503: ...Part 3 Appendixes 483 ...
Страница 504: ...484 User s Guide and Maintenance Information ...
Страница 508: ...488 User s Guide and Maintenance Information ...
Страница 529: ......
Страница 530: ...Part Number 27H0678 Printed in the U S A SA33 3285 02 1P P N 27H0678 ...
Страница 531: ...Spine information Advanced SerialRAID Adapters User s Guide and Maintenance Information ...