3. A list of protected member disk drives is displayed:
COMMAND STATUS
Command: OK
stdout: yes
stderr: no
Before command completion, additional instructions may appear below.
ssa1
Component
Location
Size
Pool
Protected Status
hdisk4
raid_10
pdisk13
04-02-REGY-06-P
18.2GB pool_B2
yes
good
pdisk11
04-02-REGY-08-P
9.2GB pool_B1
yes
good
pdisk3
04-02-REGY-05-P
9.2GB pool_B2
yes
good
pdisk6
04-02-REGY-03-P
9.2GB pool_B1
yes
good
pdisk7
04-02-REGY-01-P
9.2GB pool_B2
yes
good
pdisk15
04-02-REGY-07-P
18.2GB pool_B1
yes
good
F1=HelpF2=Refresh
F3=Cancel
F6=Command
F8=Image
F9=Shell
F10=Exit
/=Find
n=Find Next
The columns of information displayed on the screen have the following meanings:
Component
The array member disk drive of the hdisk that is listed on the screen.
Location
The physical location code of the array member disk drive.
Size
The size of the array member disk drive. This value is useful to know, if
you have assigned a hot spare disk drive to a pool, but the array member
disk drive is too large to be protected by the hot spare disk drive.
Pool
The pool to which the array member disk drive is assigned.
Protected
If set to yes, this field indicates that if the array member disk drive fails, a
hot spare disk drive is available to replace it. That hot spare disk drive is
selected from the listed hot spare pool or, if no hot spare disk drives are
available in that pool, and Choose Hot Spare Only from Preferred Pool
is set to no (see “Changing or Showing the Attributes of an SSA RAID
Array” on page 135), the hot spare disk drive is selected from another pool.
If set to no, this field indicates that the array member disk drive is not
protected. No suitable hot spare disk exists in the listed pool, and if
Choose Hot Spare Only from Preferred Pool is set to no (see “Changing
or Showing the Attributes of an SSA RAID Array” on page 135), no suitable
hot spare disk exists in any other hot spare pool.
78
User’s Guide and Maintenance Information
Содержание Advanced SerialRAID Adapters SA33-3285-02
Страница 1: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Страница 2: ......
Страница 3: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Страница 16: ...xiv User s Guide and Maintenance Information ...
Страница 18: ...xvi User s Guide and Maintenance Information ...
Страница 21: ...Part 1 User Information 1 ...
Страница 22: ...2 User s Guide and Maintenance Information ...
Страница 48: ...28 User s Guide and Maintenance Information ...
Страница 64: ...44 User s Guide and Maintenance Information ...
Страница 76: ...56 User s Guide and Maintenance Information ...
Страница 212: ...192 User s Guide and Maintenance Information ...
Страница 228: ...208 User s Guide and Maintenance Information ...
Страница 230: ...210 User s Guide and Maintenance Information ...
Страница 254: ...234 User s Guide and Maintenance Information ...
Страница 274: ...254 User s Guide and Maintenance Information ...
Страница 330: ...310 User s Guide and Maintenance Information ...
Страница 331: ...Part 2 Maintenance Information 311 ...
Страница 332: ...312 User s Guide and Maintenance Information ...
Страница 338: ...318 User s Guide and Maintenance Information ...
Страница 430: ...410 User s Guide and Maintenance Information ...
Страница 503: ...Part 3 Appendixes 483 ...
Страница 504: ...484 User s Guide and Maintenance Information ...
Страница 508: ...488 User s Guide and Maintenance Information ...
Страница 529: ......
Страница 530: ...Part Number 27H0678 Printed in the U S A SA33 3285 02 1P P N 27H0678 ...
Страница 531: ...Spine information Advanced SerialRAID Adapters User s Guide and Maintenance Information ...