background image

      

 

Parts Listing (Type 9306 Model 900)

1

10

11

2

3

4

5

6

7

8

9

74

IBM PC Server/Netfinity Racks HMM 

 

Содержание 9306 001

Страница 1: ...001 4QS 4QX 9QS 9QX 9TS 9TX 200 900 S83H 9585 04 IBM PC Server Netfinity Racks Type 9306 Type 9308 Hardware Maintenance Manual August 1999 Use this manual with the IBM Servers Hardware Maintenance Ma...

Страница 2: ......

Страница 3: ...85 04 IBM PC Server Netfinity Racks Type 9306 Type 9308 Hardware Maintenance Manual August 1999 Use this manual with the IBM Servers Hardware Maintenance Manuals We Want Your Comments Please see page...

Страница 4: ...n these changes will be incorporated in new editions of the publication IBM may make improvements and or changes in the product s and or the program s described in this publication at any time This pu...

Страница 5: ...9TS 9TX The IBM Netfinity Rack enclosure models are Type 9306 Models 001 200 900 Type 9308 Models 42P 42X This supplement should be used with the related service information in the IBM PC Servers Hard...

Страница 6: ...00 701 720 750 755 IBM Mobile Systems Hardware Maintenance Manual Volume 2 S82G 1502 ThinkPad Computers ThinkPad 365 760 IBM Mobile Systems Hardware Maintenance Manual Volume 3 S82G 1503 Monitors Disp...

Страница 7: ...25 Locations 25 Parts Listing Type 9306 Model 001 31 Type 9306 Model 200 33 Features 33 Locations 33 Parts Listing Type 9306 Model 200 52 Type 9306 Model 900 55 Features 55 Locations 55 Parts Listing...

Страница 8: ...vi IBM PC Server Netfinity Racks HMM...

Страница 9: ...IBM PC Server Netfinity Rack Enclosures General Checkout 2 Power Checkout 4 Powering Off The Rack 5 Copyright IBM Corp 1996 1997 1998 1999 1...

Страница 10: ...ernal power cord is in good condition and properly connected to a known good power source Ensure the internal power cables are in good condition and properly connected The internal power cables connec...

Страница 11: ...way 1 Device cable connects between the server selector unit and the server that was selected when the failure occurred 2 Server selector cable connects between the server selector keypad and the serv...

Страница 12: ...e Ensure the internal power cables are in good condition and properly connected The internal power cables connect between the power distribution unit and the servers installed in the server rack Ensur...

Страница 13: ...nd the installed servers To power off the IBM PC Server Netfinity Rack 1 Shut down and power off all installed servers 2 Power off the server selector unit 3 If a UPS system is installed in the rack p...

Страница 14: ...6 IBM PC Server Netfinity Racks HMM...

Страница 15: ...selector works independently from the server s operating systems enabling the connected servers to run different operating systems These IBM 9306 PC Server Rack Enclosure models are shipped preassemb...

Страница 16: ...wer off the rack see Powering Off The Rack on page 5 Server Selector Console To remove the Server Selector Console 1 Power off the rack 2 Use an 1 8 inch allen wrench to remove screws 3 Disconnect the...

Страница 17: ...ower off the rack 2 Unplug the keyboard mouse video cables and the power cord 3 Remove the server selector console 4 With one person bracing the server selector unit from below have the second person...

Страница 18: ...1 K 2 M 2 K 3 M 3 K 4 M 4 K 5 M 5 K 6 M 6 K 7 M 7 K 8 M 8 Server Monitor Connections AC Power Input Server Selector Unit On Off Switch Server Rack Mouse Connection Server Rack Keyboard Connection Serv...

Страница 19: ...m the power distribution unit 3 Using a Phillips screwdriver remove the four screws from the front of the power distribution unit Note These screws are held in place by nuts and washers Hold the nut w...

Страница 20: ...that secure the cooling fan to the top of the rack cabinet 5 Remove the cooling fan from the cabinet Note When installing the fan make sure that the green and yellow ground wire is attached to one of...

Страница 21: ...le latch rails 1 Power off the rack 2 Open the rear door of the rack cabinet and remove the pin 1 that secures the sliding tray to the cable management arm 3 Loosen the thumbscrews 2 on the sliding tr...

Страница 22: ...y and fully extend the sliding tray 4 Push in on the spring of the right rear locking tab 3 and push the sliding tray approximately two inches into the cabinet 5 Release both left and right forward lo...

Страница 23: ...to the sliding rails that you want to remove See Sliding Trays on page 13 3 Use a 3 32 inch allen wrench to remove the four screws that secure each of the sliding rails to the rack cabinet Note You wi...

Страница 24: ...Parts Listing Type 9306 19 Inch Models 9QS 9TS and 9QX 9TX 1 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22 21 23 24 2 3 4 28 29 30 25 26 27 16 IBM PC Server Netfinity Racks HMM...

Страница 25: ...15 Hinge Set for Rear Door 76H0389 16 External Power Cord Australia Europe Israel Italy New Zealand South America India U K Denmark USA External Power Cord Option 6 Ft 14F1559 14F1554 14F1561 14F1560...

Страница 26: ...iscellaneous Parts Kit 07H0057 Rack Nut Holder 10 32 8 each Keeper Nut 8 32 Zinc 8 each Keeper Nut 10 32 6 each Screw 6 32 x 5 16 2 each Screw 6 32 x 1 4 Button Head Socket Cap Allen 8 each Screw 10 3...

Страница 27: ...Rack Enclosure Kits Type 9306 FRU Server Tray Interlock Kit Cam 1 each Spring 1 each 07H0091 Type 9306 Models 4QS 4QX 9QS 9QX 9TS 9TX 19...

Страница 28: ...Parts Listing Type 9306 24 Inch Models 4QS and 4QX 1 5 6 7 8 9 10 11 12 18 19 20 21 22 23 13 14 15 16 17 2 3 4 28 29 30 26 27 24 25 20 IBM PC Server Netfinity Racks HMM...

Страница 29: ...H0055 15 Rear Door 24 Inch 07H0047 16 External Power Cord Australia Europe Israel Italy New Zealand South America India U K Denmark USA External Power Cord Option 6 Ft 14F1559 14F1554 14F1561 14F1560...

Страница 30: ...ach Keeper Nut 10 32 6 each Screw 6 32 x 5 16 2 each Screw 6 32 x 1 4 Button Head Socket Cap Allen 8 each Screw 10 32 x 3 8 Button Head Socket Cap 8 each Screw 6 32 x 3 8 Button Head Socket Cap 2 each...

Страница 31: ...Top and Bottom 34 Inch 1 each Spacer Body 70 Inch 2 each Screw 10 32 x 3 8 Button Head Socket cap 8 each Screw 1 4 20 x 1 2 Button Head Socket cap 8 each Whiz Lock Flange Nut 1 4 20 8 each Screw 6 32...

Страница 32: ...24 IBM PC Server Netfinity Racks HMM...

Страница 33: ...enclosure Locations This section contains the following Casters Foot Pads Front Cover Rear Panel Device side rails Stacking NetBAY3 enclosures Important The maximum server weight is 77 kg 170 lb Refer...

Страница 34: ...Casters Two fixed casters 1 at the front of the NetBAY3 enclosure Two swivel casters 2 at the rear of the NetBAY3 enclosure Foot Pads 26 IBM PC Server Netfinity Racks HMM...

Страница 35: ...Front Cover Type 9306 Model 001 27...

Страница 36: ...Rear Panel Note Make sure empty NetBAY3 enclosures no devices installed have the rear cover securely attached 28 IBM PC Server Netfinity Racks HMM...

Страница 37: ...Device Side Rails Stacking NetBAY3 Enclosures Note Make sure NetBAY3 enclosures in a stack are securely fastened together Type 9306 Model 001 29...

Страница 38: ...Note The maximum server weight is 77 kg 170 lb 30 IBM PC Server Netfinity Racks HMM...

Страница 39: ...e Frame 03K8797 2 Front Bezel Assembly with Lock and Keys 03K8798 3 Foot Pads Qty 4 03K8800 4 Casters Fixed Front Qty 2 12J3279 4 Casters Swivel Rear Qty 2 12J3283 5 3 U Blank Panel 03K8799 Miscellane...

Страница 40: ...32 IBM PC Server Netfinity Racks HMM...

Страница 41: ...rvers IBM Netfinity Servers and related equipment Locations This section contains the following Side Panel on page 34 Selector Switch Locations on page 35 Power distribution Unit on page 38 Blank Beze...

Страница 42: ...Side Panel Locked Unlocked 34 IBM PC Server Netfinity Racks HMM...

Страница 43: ...tion 1 0 Thr ee K M K M Two Thr ee K M Thr ee K M K M Two Selector Switch in monitor compartment FRONT REAR One K M Three K M K M Two Aux Reset Im po rta nt Inf or ma tio n 1 0 Three K M K M Two Three...

Страница 44: ...Tiered Switch Configuration One K M Three K M K K M Two Aux Reset Monitor Keyboard Mouse Connectors One K M Three K M K K M Two Aux Reset System 1 to 8 System 1 1 to 1 8 One eight port primary select...

Страница 45: ...ch Server 1 Server 2 Server 3 Server 4 Console Cable Set Single Selector Switch Monitor Keyboard Mouse Server 1 Server 2 Server 3 Server 4 Secondary Selector Switch Console Cable Set Primary Selector...

Страница 46: ...t REAR FRONT Power Distribution vertical installation Power Distribution horizontal installation Note There are two types of Power distribution units available High voltage Low voltage 38 IBM PC Serve...

Страница 47: ...Blank Bezel Fixed Shelf Type 9306 Model 200 39...

Страница 48: ...Keyboard Tray To remove the tray from the side rails pull up on the left rail tab and push down on the right rail tab 40 IBM PC Server Netfinity Racks HMM...

Страница 49: ...Configuring the Selector Switch Note Some selector switch units have different functions and displays Refer to the Apex PC Solutions Outlook Concentrator User Guide This guide is shipped with the Sele...

Страница 50: ...eric key that corresponds to the server s port number and then press Enter The symbols after the Port or Name columns on the menu show the status of the port as follows Type of Symbol Symbol Meaning P...

Страница 51: ...ter The selector switch enters the scan mode and the display returns to the status flag To cancel the operation press Esc any time before you press Enter To cancel the scan mode press any key or move...

Страница 52: ...reestablish keyboard and mouse communications Resetting the Mouse and Keyboard Resetting the mouse and keyboard restores the default setting for the selected server Press the Print Screen key Press th...

Страница 53: ...u want this server to be connected to the monitor and keyboard before switching to the next server in the scan 6 Press the Down Arrow key to move the highlighting to the next port in the Port column a...

Страница 54: ...try for which the server name is to be entered or changed Type in the name of the server using up to 12 alphanumeric characters Note Legal characters are A Z 0 9 and the dash character Lowercase lette...

Страница 55: ...the highlighting to the Setup list Using the Up Arrow and Down Arrow keys move the highlighting to OSCAR On Screen Configuration and Activity Reporting and press the Enter key The following Attribute...

Страница 56: ...ext in the menu and windows The larger the value the larger the text Horizontal Vertical Determines the position of the menu or window on the screen Background Determines the menu or window background...

Страница 57: ...up menu 3 Using the Up Arrow and Down Arrow keys move the highlight to Flag and press the Enter key The following menu appears Flag Attributes Enabled Names On Row 14 Column 1 Color 2 Text Mode Transp...

Страница 58: ...ype to the port number associated with the server Note When tiering you must make the primary selector switch aware of the secondaries through the assignment Assign a device type as follows 1 Press th...

Страница 59: ...ssing the Reset button on the back panel of the selector switch Note Pressing the reset button might recover the device settings without having to power off then power on all the servers Making Connec...

Страница 60: ...Parts Listing Type 9306 Model 200 1 2 3 5 6 7 8 9 4 10 52 IBM PC Server Netfinity Racks HMM...

Страница 61: ...28L0553 Label EIA Unit Numbers 28L0551 Miscellaneous Parts Kit Includes Caged Nut M6 6 Screw M6 Hex Head 6 Screw M6 Socket 5 Washer 10 32 flat 6 Hex Nut M6 5 Screw M6X12 Button Head 5 76H4950 Rack Enc...

Страница 62: ...54 IBM PC Server Netfinity Racks HMM...

Страница 63: ...ity Servers and related equipment Locations This section contains the following Side Panel on page 56 Selector Switch Locations on page 57 Power distribution Unit on page 60 Blank Bezel on page 61 Fix...

Страница 64: ...Side Panel Locked Unlocked 56 IBM PC Server Netfinity Racks HMM...

Страница 65: ...tion 1 0 Thr ee K M K M Two Thr ee K M Thr ee K M K M Two Selector Switch in monitor compartment FRONT REAR One K M Three K M K M Two Aux Reset Im po rta nt Inf or ma tio n 1 0 Three K M K M Two Three...

Страница 66: ...nitor Tiered Switch Configuration One K M Three K M K K M Two Aux Reset Monitor Keyboard Mouse Connectors One K M Three K M K K M Two Aux Reset System 1 to 8 System 1 1 to 1 8 One eight port primary s...

Страница 67: ...ch Server 1 Server 2 Server 3 Server 4 Console Cable Set Single Selector Switch Monitor Keyboard Mouse Server 1 Server 2 Server 3 Server 4 Secondary Selector Switch Console Cable Set Primary Selector...

Страница 68: ...t REAR FRONT Power Distribution vertical installation Power Distribution horizontal installation Note There are two types of Power distribution units available High voltage Low voltage 60 IBM PC Serve...

Страница 69: ...Blank Bezel Fixed Shelf Type 9306 Model 900 61...

Страница 70: ...Keyboard Tray To remove the tray from the side rails pull up on the left rail tab and push down on the right rail tab 62 IBM PC Server Netfinity Racks HMM...

Страница 71: ...Configuring the Selector Switch Note Some selector switch units have different functions and displays Refer to the Apex PC Solutions Outlook Concentrator User Guide This guide is shipped with the Sele...

Страница 72: ...eric key that corresponds to the server s port number and then press Enter The symbols after the Port or Name columns on the menu show the status of the port as follows Type of Symbol Symbol Meaning P...

Страница 73: ...ter The selector switch enters the scan mode and the display returns to the status flag To cancel the operation press Esc any time before you press Enter To cancel the scan mode press any key or move...

Страница 74: ...reestablish keyboard and mouse communications Resetting the Mouse and Keyboard Resetting the mouse and keyboard restores the default setting for the selected server Press the Print Screen key Press th...

Страница 75: ...u want this server to be connected to the monitor and keyboard before switching to the next server in the scan 6 Press the Down Arrow key to move the highlighting to the next port in the Port column a...

Страница 76: ...try for which the server name is to be entered or changed Type in the name of the server using up to 12 alphanumeric characters Note Legal characters are A Z 0 9 and the dash character Lowercase lette...

Страница 77: ...the highlighting to the Setup list Using the Up Arrow and Down Arrow keys move the highlighting to OSCAR On Screen Configuration and Activity Reporting and press the Enter key The following Attribute...

Страница 78: ...ext in the menu and windows The larger the value the larger the text Horizontal Vertical Determines the position of the menu or window on the screen Background Determines the menu or window background...

Страница 79: ...up menu 3 Using the Up Arrow and Down Arrow keys move the highlight to Flag and press the Enter key The following menu appears Flag Attributes Enabled Names On Row 14 Column 1 Color 2 Text Mode Transp...

Страница 80: ...ype to the port number associated with the server Note When tiering you must make the primary selector switch aware of the secondaries through the assignment Assign a device type as follows 1 Press th...

Страница 81: ...ssing the Reset button on the back panel of the selector switch Note Pressing the reset button might recover the device settings without having to power off then power on all the servers Making Connec...

Страница 82: ...Parts Listing Type 9306 Model 900 1 10 11 2 3 4 5 6 7 8 9 74 IBM PC Server Netfinity Racks HMM...

Страница 83: ...Door Hinge Pin 1 12J4469 Label EIA Unit Numbers 12J4471 Miscellaneous Parts Kit Includes Caged Nut M6 6 Screw M6 Hex Head 6 Screw M6 Socket 5 Washer 10 32 flat 6 Hex Nut M6 5 Screw M6X12 Button Head...

Страница 84: ...centrator with Hardware 8 port 76H4948 Concentrator with Hardware 4 port 28L0543 Low Voltage Power Distribution Unit 8 AC sockets With Hardware 12J4472 208 V Power Distribution Unit 10 AC sockets With...

Страница 85: ...nity Server 9308 Rack Models 42P 42X enclosure is an industry standard 19 inch rack cabinet that houses multiple IBM Netfinity Servers and related equipment Primary Rack Model 42P Extension Rack Model...

Страница 86: ...ket on page 83 Rack attachment on page 84 Installing L channel support rails to rack mounting brackets on page 85 Installing an optional device on sliding rails on page 86 Fixed shelf on page 87 Singl...

Страница 87: ...security feature 1 inside the rear of the rack which secures a panel in place 2 Push down the release latches 2 and tilt the panel slightly towards you then lift the panel to remove it Note Reverse t...

Страница 88: ...sen the four screws located on the top of the rack which hold each side panel in place 2 Tilt the side panel slightly towards you then remove it from the rack Note Reverse this procedure to install to...

Страница 89: ...Grasp the door 1 firmly with both hands and lift it upwards until it is fully off of the hinges 2 Notes 1 Reverse this procedure to reinstall front and rear doors 2 The top hinge pin is longer than th...

Страница 90: ...r to remove the top 6U of the Rack 1 Install the support bars 1 in the front and the rear of the rack using two screws per support bar 2 Remove the 16 screws eight per side that secure the top 6U 2 in...

Страница 91: ...Lower each of the four feet 1 just enough so that they touch the floor Note The rack casters will support the weight of the 9308 Rack The feet prevent the rack from rolling 2 Secure the stabilizer bra...

Страница 92: ...front and one on the bottom rear b Install two threaded standoffs on the rack on the right one on the bottom front and one on the top rear 3 Attach the racks together by securing the four bolts and wa...

Страница 93: ...1 and rear 2 of a l channel support bracket is secured with clip nuts 3 and screws with washers 4 The length of the l channel is adjusted on the inside of the bracket with the screws 5 provided To sec...

Страница 94: ...rails at the front 1 and rear 2 of the optional device 2 Using screws secure the device to the extended slide rails 3 then slide the device into the rack 3 Install the cable management arm on the rear...

Страница 95: ...ed shelf 1 Determine the location for the fixed shelf within the rack 2 Secure the threaded mounting brackets 1 to the rear of the shelf then secure the brackets to the rack with two screws and clip n...

Страница 96: ...kg 150 lbs To install a single slide shelf 1 Secure the mounting rails to the front 1 and rear 2 of the rack adjusting them as needed 2 Attach the cable management arm to the rear of the shelf and to...

Страница 97: ...all a keyboard tray 1 Secure the slide rails to the front 1 and rear 2 of the rack adjusting them as needed 2 Slide the keyboard tray onto the rails and store the keyboard 3 in the area provided Type...

Страница 98: ...itor shelf bracket in the rear of the rack 1 with two screws per side 2 Place the monitor shelf inside of the rack resting on the rear bracket then secure it to the front of the rack 2 with three scre...

Страница 99: ...ove it 2 Install the flat panel monitor base 1 on the monitor 3 Install the mounting studs 2 and bumpers 3 on the keyboard tray 4 Secure the monitor base inside of the keyboard tray with the screws 4...

Страница 100: ...els can occupy 1U 3U or 5U of space on a rack To install a blank filler panel 1 Determine the size 1U 3U or 5U panel you need 2 Secure the blank filler panel in place with four screws and clip nuts 92...

Страница 101: ...Parts Listing Type 9308 Model 42P 42X 1 2 3 4 5 6 7 Type 9308 Model 42P 42X 93...

Страница 102: ...e Cover 05N4905 7 Upper Side Cover 05N4906 Caster Fixed 4 05N4915 Caster Swivel 4 05N4916 Door Latch w Lock 05N4903 Door Strike 2 05N4904 EIA Mounting Flange Label 1 42U Decorative 05N4917 EIA Mountin...

Страница 103: ...all sliding devices exceeding this weight The center of gravity for an extended unit cannot exceed 362 mm 14 25 in from the face of the rack If an extended device exceeds this distance the configured...

Страница 104: ...le dispositivos em trilhos que excedam este peso O centro de gravidade para uma unidade estendida n o pode exceder 362 mm 14 25 in da frente do rack Se um dispositivo estendido exceder esta dist ncia...

Страница 105: ...k e de f cil acesso 4 PERIGO Conecte todos os dispositivos de um rack aos dispositivos de energia instalados no mesmo rack N o conecte um cabo de alimenta o de um dispositivo instalado em um rack a um...

Страница 106: ...veurs et les blocs d alimentation dans la partie inf rieure de l armoire Installez toujours les composants les plus lourds dans la partie inf rieure de l armoire Installez toujours les blocs d aliment...

Страница 107: ...ine Einheiten mit h heren Gewicht einbauen Der Schwerpunkt einer ausgefahrenen Einheit darf nicht mehr als 362 mm von der Frontseite des Geh use entfernt liegen Liegt der Schwerpunkt weiter entfernt k...

Страница 108: ...in einem Geh use befindlichen Einheit an eine Netzeinheit in einem anderen Geh use anschlie en 1 PERICOLO Il peso massimo consentito per i dispositivi montati su slitte di 80 kg Non installare dispos...

Страница 109: ...il supporto stabilizzatore Non aprire pi di un unit scorrevole alla volta 3 PERICOLO Inserire i cavi di alimentazione del rack in prese elettriche situate vicino al rack e di facile accesso 4 PERICOLO...

Страница 110: ...le dispositivos deslizantes que excedan este peso El centro de gravedad de una unidad extendida no puede exceder los 362 mm 14 25 pgda desde la parte frontal del bastidor Si un dispositivo extendido e...

Страница 111: ...extienda m s de un dispositivo deslizante a la vez 3 PELIGRO Enchufe los cables de alimentaci n del bastidor en tomas el ctricas que est n situadas cerca de ste y a las que se pueda acceder f cilmente...

Страница 112: ...idor pesada Voc ir precisar de duas pess oas para remover com seguran a esta unidade Le bloc s lecteur est lourd Faites vous aider pour le retirer en toute Die Server Selektor Einheit ist schwer Um si...

Страница 113: ...hanical hazards such as loose or missing hardware The guide consists of a series of steps presented in a checklist Begin the checks with the power off and the power cord disconnected Checklist 1 Check...

Страница 114: ...ching your clothing Most clothing is insulative and retains a charge even when you are wearing a wrist strap Use the black side of a grounded work mat to provide a static free work surface The mat is...

Страница 115: ...Diskette Version Type and version level Hardware configuration Print print screen configuration currently in use BIOS level Operating system software Type and version level Important To eliminate con...

Страница 116: ...IBM Warranty Parts Claims Center Number Information 919 517 0001 Bulletin Board Service PC Company 800 426 8322 Customer Education Business Unit 800 999 0052 Customized Operational Services 800 237 48...

Страница 117: ...s 800 663 7662 Lexmark Product Information 800 263 2769 Parts Orders Exchange or Emergency 416 443 5808 Fax Parts Regular Orders Exchange 416 443 5755 Parts Orders Inquiries 514 938 3022 PC Co Bulleti...

Страница 118: ...ionally equivalent product program or service may be used instead of the IBM product program or service The evaluation and verification of operation in conjunction with other products except those exp...

Страница 119: ...d then fax it to IBM HMM Survey at 919 543 8167 USA Name Phone Number 1 Do you like this manual _____ Yes _____ No 2 What would you like to see added changed or deleted in this manual 3 What is your s...

Страница 120: ...Look4 and OSCAR are trademarks of Apex PC Solutions Inc Other company product and service names used in this publication may be trademarks or service marks of others EduQuest HelpCenter HelpClub IBM N...

Страница 121: ......

Страница 122: ...IBM Part Number 09N1031 Printed in U S A S83H 9585 4...

Отзывы: