Note:
See
“System”
on
page
108
to
determine
which
components
a
field
service
technician
should
replace.
Beep/symptom
FRU/action
3-3-1
(Memory
size
mismatch
occurred.)
1.
DIMM
2.
Battery
3-3-2
(Critical
SMBUS
error
occurred)
1.
Disconnect
the
server
power
cord
from
outlet,
wait
30
seconds,
and
retry.
2.
System
board.
3.
DIMMs.
4.
Hard
disk
drive
backplane.
5.
Power
supply.
6.
Power
cage
assembly.
3-3-3
(No
operational
memory
in
system)
1.
Install
or
reseat
the
memory
modules,
and
then
do
a
3
boot
reset.
(For
more
information
on
a
3
boot
reset,
see
Chapter
2,
“Configuring
the
server,”
on
page
9).
2.
DIMMs.
3.
Memory
board.
4.
System
board.
4-4-4
(Optional
system
management
adapter
not
installed
in
slot
1
or
not
functioning
correctly)
1.
Verify
that
the
adapter
is
installed
in
the
system
management
adapter
slot.
2.
Adapter.
3.
System
board.
Two
short
beeps
(Information
only,
the
configuration
has
changed)
1.
Run
Diagnostics.
2.
Run
the
Configuration/Setup
Utility
program.
Three
short
beeps
1.
Reseat
the
DIMMs
2.
Locate
the
failing
DIMMs:
a.
Remove
all
DIMMs
from
the
server.
b.
Beginning
with
the
primary
bank
of
DIMMs,
return
one
bank
of
DIMMs
to
the
server
at
a
time,
restarting
the
server
each
time,
until
the
beep
code
error
returns.
c.
Replace
one
pair
of
DIMMs
at
a
time
in
the
failing
bank
with
an
identical
pair
of
known
good
DIMMs,
restarting
the
server
after
each
pair,
until
the
beep
code
error
returns.
d.
Replace
one
DIMM
at
a
time
in
the
failing
pair
with
an
identical
known
good
DIMM,
restarting
the
server
after
each
DIMM,
to
identify
the
failed
DIMM.
If
the
beep
code
error
remains
after
you
have
replaced
both
DIMMs,
go
to
step
3b.
e.
Repeat
steps
2b
through
2d
until
you
have
checked
all
memory
banks.
3.
Replace
the
following
components,
one
at
a
time,
in
the
order
shown:
a.
DIMMs
b.
(Trained
service
technician
only)
System
board
76
xSeries
346
Types
8840
and
1880:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Содержание 884015U
Страница 1: ...xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 2: ......
Страница 3: ...xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 8: ...vi xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 18: ...8 xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 82: ...72 xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 139: ...Appendix B Safety information 129...
Страница 140: ...130 xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 141: ...Appendix B Safety information 131...
Страница 142: ...132 xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 143: ...Appendix B Safety information 133...
Страница 155: ...Appendix B Safety information 145...
Страница 156: ...146 xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 157: ...Appendix B Safety information 147...
Страница 158: ...148 xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 164: ...154 xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 170: ...160 xSeries 346 Types 8840 and 1880 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 175: ......
Страница 176: ...Part Number 25K8115 Printed in USA 1P P N 25K8115...