Features
and
specifications
The
following
information
is
a
summary
of
the
features
and
specifications
of
the
server.
Depending
on
the
server
model,
some
features
might
not
be
available,
or
some
specifications
might
not
apply.
Table
1.
Features
and
specifications
Microprocessor:
v
Intel
™
Xeon
®
2.8
GHz
or
higher
depending
on
server
model
v
Support
for
up
to
two
microprocessors
with
Intel
Hyper-Threading
Technology
and
EM64T
(extended
memory
64
bit
technology)
v
800
MHz
front-side
bus
(FSB)
Memory:
v
Minimum:
512
MB
v
Maximum:
16
GB
v
Type:
2-way
interleaved
PC3200,
400
MHz,
ECC
DDR
II
SDRAM,
registered
DIMMs
only
v
Sizes:
256
MB,
512
MB,
1
GB,
2
GB
(when
available)
Drives:
v
DVD-ROM
drive
(available
only
with
3.5-inch
hard
disk
drive
configurations)
Expansion
bays:
Comes
in
3
configurations:
v
Configuration
1
and
2
–
One
9.5-mm
high
DVD-ROM
drive
(optional)
–
Two
3.5-inch
hot-swap
SCSI
or
two
3.5-inch
non-hot-swap
(simple
swap)
SATA
hard
disk
drives
v
Configuration
3
–
Four
2.5-inch
hot-swap
SCSI
hard
disk
drives
Expansion
slots:
v
One
PCI-X
133
MHz
or
PCI
Ex8,
full-length,
full
height
(
Note:
PCI-E
x8
(PCI-E)
requires
an
optional
riser
card)
v
One
PCI-X
100
MHz,
half
length,
low-profile
Power
supply:
v
585
watt
hot-swap
power
supply
standard
v
Optional
redundant
585
watt
power
supply
Size:
v
Height:
43
mm
(1.69
in.)
v
Depth:
686
mm
(27.0
in.)
v
Width:
440
mm
(17.32
in.)
v
Weight:
approximately
15.6
kg
(34.5
lb)
when
fully
configured
or
12.7
kg
(28
lb)
minimum
Integrated
functions:
v
Baseboard
management
controller
(BMC)
v
One
LSI
Ultra320
SCSI
controller
with
RAID
levels
1
and
1E
capability
v
Two
Broadcom
10/100/1000
Ethernet
controllers
with
Wake
on
LAN
®
feature
and
Alert
Standard
Format
support
v
Three
Universal
Serial
Bus
(USB)
ports
v
One
serial
port
v
Keyboard
port
v
Mouse
port
v
Video
port
Acoustical
noise
emissions:
v
Sound
power,
idling:
6.9
bel
maximum
v
Sound
power,
operating:
6.9
bel
maximum
Environment:
v
Air
temperature:
–
Server
on:
10°
to
35°C
(50.0°
to
95.0°F);
altitude:
0
to
2133
m
(6998.0
ft)
–
Server
off:
10°
to
43°C
(50.0°
to
109.4°F);
maximum
altitude:
2133
m
(6998.0
ft)
v
Humidity:
–
Server
on:
8%
to
80%
–
Server
off:
8%
to
80%
Heat
output:
Approximate
heat
output
in
British
thermal
units
(Btu)
per
hour:
v
Minimum
configuration:
587
Btu/hr
(172
watts)
v
Maximum
configuration:
1878
Btu/hr
(550
watts)
Electrical
input:
v
Sine-wave
input
(50-60
Hz)
required
v
Input
voltage
low
range:
–
Minimum:
100
V
ac
–
Maximum:
127
V
ac
v
Input
voltage
high
range:
–
Minimum:
200
V
ac
–
Maximum:
240
V
ac
v
Input
kilovolt-amperes
(kVA),
approximately:
–
Minimum:
.172
kVA
–
Maximum:
.550
kVA
Notes:
1.
Power
consumption
and
heat
output
vary
depending
on
the
number
and
type
of
optional
features
installed
and
the
power-management
optional
features
in
use.
2.
These
levels
were
measured
in
controlled
acoustical
environments
according
to
the
procedures
specified
by
the
American
National
Standards
Institute
(ANSI)
S12.10
and
ISO
7779
and
are
reported
in
accordance
with
ISO
9296.
Actual
sound-pressure
levels
in
a
given
location
might
exceed
the
average
values
stated
because
of
room
reflections
and
other
nearby
noise
sources.
The
declared
sound-power
levels
indicate
an
upper
limit,
below
which
a
large
number
of
computers
will
operate.
4
IBM
xSeries
336
Type
8837:
Installation
Guide
Содержание 883725U
Страница 3: ...IBM xSeries 336 Type 8837 Installation Guide ERserver...
Страница 18: ...6 IBM xSeries 336 Type 8837 Installation Guide...
Страница 38: ...26 IBM xSeries 336 Type 8837 Installation Guide...
Страница 46: ...34 IBM xSeries 336 Type 8837 Installation Guide...
Страница 64: ...52 IBM xSeries 336 Type 8837 Installation Guide...
Страница 66: ...54 IBM xSeries 336 Type 8837 Installation Guide...
Страница 112: ...100 IBM xSeries 336 Type 8837 Installation Guide...
Страница 113: ......
Страница 114: ...Part Number 25R4613 Printed in USA 1P P N 25R4613...