4. Check the hard disk drive status indicators to verify that the hard disk drive is
operating properly.
Non-hot-swap drive installation
Before you install drives in the server, verify that you have all the cables and any
other equipment specified in the documentation that comes with the internal drive.
You might also need to perform certain preinstallation activities. Some of the steps
are required only during the initial installation of an option.
Slide rails
Side latches
Slide rail
Slide rail
Filler panel
Drive
To install a non-hot-swap drive:
1. Review the information in“Before you begin” on page 40.
2. Turn off the server and peripheral devices and then remove the cover and
bezel. (See “Removing the cover and bezel” on page 42.)
3. Remove the filler panel from the bay opening by pushing in the side latches
and pulling the filler panel away from the server. You do not need the filler
panel when you have a drive installed in the bay.
Note:
The electromagnetic interference (EMI) integrity and cooling are
protected by having the non-hot-swap bays covered or occupied. When
you install a drive, save the filler panel from the bay, in case you later
remove the drive and do not replace it with another.
4. Touch the static-protective bag containing the drive to any unpainted metal
surface on the server; then, remove the drive from the bag and place it on a
static-protective surface.
5. Set any jumpers or switches on the drive according to the documentation that
comes with the drive.
6. Install rails on the drive.
v
If you are installing a standard-size drive:
a. Pull the blue slide rails off the back of the filler panel.
b. Clip the rails onto the sides of the drive.
v
If you are installing a digital linear tape (DLT) backup drive, use the metal
slide rails and screws that are shipped in the box that contains the server
documentation.
7. Place the drive so that the slide rails engage in the bay guide rails. Push the
drive into the bay until it clicks into place.
50
Hardware Maintenance Manual: xSeries 342 Type 8669
Содержание 8669 - Eserver xSeries 342
Страница 1: ...Hardware Maintenance Manual xSeries 342 Type 8669 ERserver...
Страница 2: ......
Страница 3: ...Hardware Maintenance Manual xSeries 342 Type 8669 ERserver...
Страница 10: ...viii Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 32: ...22 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 42: ...32 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 86: ...76 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 114: ...104 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 129: ...Related service information 119...
Страница 130: ...120 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 131: ...Related service information 121...
Страница 132: ...122 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 133: ...Related service information 123...
Страница 134: ...124 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 135: ...Related service information 125...
Страница 136: ...126 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 146: ...136 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 147: ...Related service information 137...
Страница 148: ...138 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 155: ......
Страница 156: ...Part Number 24P2922 1P P N 24P2922...