Voltage related system shutdown
Message
Action
System shutoff due to
″
X
″
current over
max value
(level-critical; system drawing
too much current on voltage
″
X
″
bus)
1.
See “Power checkout” on page 19.
System shutoff due to
″
X
″
V over voltage
(level-critical; system shutoff due to
″
X
″
supply over voltage)
1.
Check power supply connectors
2. Replace power supply
3. Replace power backplane
System shutoff due to
″
X
″
V under
voltage
(level-critical system shutoff due to
″
X
″
supply under voltage)
1.
Check power supply connectors
2. Replace power supply
3. Replace power backplane
System shutoff due to VRM
″
X
″
over
voltage
1.
Replace VRM
″
X
″
System shutoff due to excessive (< 240
VA) loading
1.
See “Power checkout” on page 19.
2. Cycle AC On/Off to enable retry
Temperature related system shutdown
Message
Action
System shutoff due to board over
temperature
(level-critical; board is over
temperature)
1.
Ensure system is being properly cooled
, see “System reliability
considerations” on page 41.
2. Replace board
System shutoff due to CPU
″
X
″
over
temperature
(level-critical; CPU
″
X
″
is over
temperature)
1.
Ensure system is being properly cooled
, see “System reliability
considerations” on page 41.
2. Replace CPU
″
X
″
System shutoff due to CPU
″
X
″
under
temperature
(level-critical; CPU
″
X
″
is under
temperature)
1.
Ambient temperature must be within normal operating
specifications,
see “Features and specifications” on page 3.
2.
System shutoff due to DASD temperature
(sensor X)
(level-critical; DASD area
reported temperature outside recommended
operating range)
1.
Ensure system is being properly cooled
, see “System reliability
considerations” on page 41.
System shutoff due to high ambient
temperature
(level-critical; high ambient
temperature)
1.
Ambient temperature must be within normal operating
specifications,
see “Features and specifications” on page 3.
System shutoff due to system board
under temperature
(level-critical; system
board is under temperature)
1.
Ambient temperature must be within normal operating
specifications
, see “Features and specifications” on page 3.
DASD checkout
Message
Action
Hard drive
″
X
″
removal detected
(level-critical; hard drive
″
X
″
has been
removed)
1.
Information only, take action as appropriate.
Symptom-to-FRU index
101
Содержание 8669 - Eserver xSeries 342
Страница 1: ...Hardware Maintenance Manual xSeries 342 Type 8669 ERserver...
Страница 2: ......
Страница 3: ...Hardware Maintenance Manual xSeries 342 Type 8669 ERserver...
Страница 10: ...viii Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 32: ...22 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 42: ...32 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 86: ...76 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 114: ...104 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 129: ...Related service information 119...
Страница 130: ...120 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 131: ...Related service information 121...
Страница 132: ...122 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 133: ...Related service information 123...
Страница 134: ...124 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 135: ...Related service information 125...
Страница 136: ...126 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 146: ...136 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 147: ...Related service information 137...
Страница 148: ...138 Hardware Maintenance Manual xSeries 342 Type 8669...
Страница 155: ......
Страница 156: ...Part Number 24P2922 1P P N 24P2922...