If
you
have
just
added
new
software
or
a
new
option
and
your
server
is
not
working,
complete
the
following
steps
before
using
the
error
symptom
charts:
1.
Remove
the
software
or
device
that
you
just
added.
2.
Run
the
diagnostic
tests
to
determine
if
your
server
is
running
correctly.
3.
Reinstall
the
new
software
or
new
device.
In
the
following
table,
if
the
entry
in
the
FRU/action
column
is
a
suggested
action,
perform
that
action;
if
it
is
the
name
of
a
component,
reseat
the
component
and
replace
it
if
necessary.
The
most
likely
cause
of
the
symptom
is
listed
first.
Error
Symptom
FRU/Action
CD
is
not
working
properly.
1.
Clean
the
CD.
2.
Run
CD-ROM
diagnostics.
3.
CD-ROM
Drive.
CD-ROM
drive
tray
is
not
working.
(The
server
must
be
powered-on)
1.
Insert
the
end
of
a
paper
clip
into
the
manual
tray-release
opening.
2.
Run
CD-ROM
diagnostics.
3.
CD-ROM
Drive.
CD-ROM
drive
is
not
recognized
.
1.
Run
Configuration/Setup,
enable
primary
IDE
channel.
2.
Check
cables
and
jumpers.
3.
Check
for
correct
device
driver.
4.
Run
CD-ROM
diagnostics.
5.
CD-ROM
Drive.
6.
System
Board.
Power
switch
does
not
work
and
reset
button
does
work.
(SW
1-1
is
force
power-on
switch.)
1.
Reseat
connector.
2.
Switch
Card.
3.
System
Board.
Diskette
drive
in-use
light
stays
on,
or
the
system
bypasses
the
diskette
drive,
or
the
diskette
drive
does
not
work
1.
If
there
is
a
diskette
in
the
drive,
verify
that:
a.
The
diskette
drive
is
enabled
in
the
Configuration/Setup
utility
program.
b.
The
diskette
is
good
and
not
damaged.
(Try
another
diskette
if
you
have
one.)
c.
The
diskette
is
inserted
correctly
in
the
drive.
d.
The
diskette
contains
the
necessary
files
to
start
the
server.
e.
The
software
program
is
OK.
f.
Cable
is
installed
correctly
(proper
orientation).
2.
Run
Diskette
Drive
Diagnostics.
3.
Cable.
4.
Diskette
Drive.
5.
System
Board.
Monitor
problems
(general).
Some
IBM
monitors
have
their
own
self-tests.
If
you
suspect
a
problem
with
the
monitor,
refer
to
the
information
that
comes
with
the
monitor
for
adjusting
and
testing
instructions.
1.
Monitor.
2.
Run
Video
Diagnostics.
If
diagnostics
pass,
the
problem
may
be
a
video
driver.
3.
Display
Adapter
/
System
Board.
No
video
1.
Make
sure
correct
machine
is
selected.
2.
Make
sure
all
cables
are
locked
down.
Drives
not
recognized
by
the
Fixed
Disk
diagnostic.
(e.g.
of
6
drives,
the
Fixed
Disk
test
only
shows
3)
Remove
the
first
drive
that
doesn’t
show
up
and
rerun
the
Fixed
Disk
diagnostic.
If
the
remaining
drives
then
show
up,
replace
the
drive
you
removed.
Chapter
6.
Symptom-to-FRU
index
107
Содержание 8649 - Eserver xSeries 225
Страница 1: ...IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 2: ......
Страница 3: ...IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 6: ...iv IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 16: ...6 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 28: ...18 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 42: ...32 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 84: ...74 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 130: ...120 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 151: ...Appendix B Related service information 141 ...
Страница 152: ...142 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 153: ...Appendix B Related service information 143 ...
Страница 154: ...144 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 155: ...Appendix B Related service information 145 ...
Страница 156: ...146 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 157: ...Appendix B Related service information 147 ...
Страница 158: ...148 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 171: ...Appendix B Related service information 161 ...
Страница 172: ...162 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 173: ...Appendix B Related service information 163 ...
Страница 174: ...164 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 175: ...Appendix B Related service information 165 ...
Страница 176: ...166 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 177: ...Appendix B Related service information 167 ...
Страница 182: ...172 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 188: ...178 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 193: ......
Страница 194: ... Part Number 25K8102 1P P N 25K8102 ...