To verify the operation of a newly installed feature or replacement part, follow these steps:
1.
Did you replace the part using either VIOS or the online diagnostics service aid's concurrent
(hot-swap) service operation?
No:
Go to step 2.
Yes:
Go to step 5.
2.
Is the system powered off?
No:
Go to step 4.
Yes:
If the system supports slow boot, set the system to perform a slow boot. For information, see
3.
Start the system and wait until the VIOS operating system login prompt displays or until apparent
system activity on the operator panel or display has stopped.
Did the VIOS login prompt display?
v
No:
If an SRN or other reference code is displayed, suspect a loose adapter or cable connection.
Review the procedures for the part that you replaced to ensure that the new part is installed
correctly. If you cannot correct the problem, collect all SRNs or any other reference code
information that you see. If the system does not start or you have no login prompt, see: Problems
with loading and starting the operating system.
If the system is partitioned, note the logical partition in which you replaced the part. Contact your
service provider for assistance.
v
Yes:
Go to step 4
4.
At the command prompt, type
diag —a
and press Enter to check for missing resources. If you see a
command prompt, go to step 5.
If the
Diagnostic selection
menu is shown with
M
appearing next to any resource, follow these
steps:
a.
Select the resource and press Enter.
b.
Select
Commit
.
c.
Follow any instructions that are shown.
d.
If a
Do you want to review the previously displayed error?
message is shown, select
Yes
and press
Enter.
e.
If an SRN is shown, suspect a loose card or connection. If no obvious problem is shown, record
the SRN and contact your service provider for assistance..
f.
If no SRN is shown, go to 5.
5.
Test the part by doing the following:
a.
At the command line, type
diagmenu
and press Enter.
b.
From the
Function Selection
menu, select
Advanced Diagnostics Routines
and press Enter.
c.
From the
Diagnostic Mode Selection
menu, select
System Verification
and press Enter.
d.
Select
All Resources
, or select the diagnostics for the individual part to test only the part you
replaced, and any devices that are attached to the part you replaced and press Enter.
Did the
Resource Repair Action
menu appear?
No:
Go to step 6.
Yes:
Go to step 7 on page 63.
6.
Did the
Testing Complete, No trouble was found
message appear?
v
No:
There is still a problem. Contact your service provider.
This ends the procedure.
v
Yes:
Select
Log Repair Action
, if not previously logged, from the
Task Selection
menu to update
the AIX error log. If the repair action was reseating a cable or adapter, select the resource
associated with that repair action. If the resource associated with your action is not displayed on
the Resource List, select
sysplanar0
and press Enter.
62
Control panel, control panel fillers, and signal cables
Содержание 8203-E4A
Страница 1: ...Power Systems Control panel control panel fillers and signal cables ...
Страница 2: ......
Страница 3: ...Power Systems Control panel control panel fillers and signal cables ...
Страница 10: ...2 Control panel control panel fillers and signal cables ...
Страница 32: ...24 Control panel control panel fillers and signal cables ...
Страница 81: ......
Страница 82: ... Printed in USA ...