BMC
POST
Watchdog
Timeout
Set
the
BMC
POST
watchdog
timeout
value.
5
minutes
is
the
default
setting.
-
System-BMC
Serial
Port
Sharing
Enable
or
disable
sharing
the
serial
port
between
the
BMC
and
the
system.
Disabled
is
the
default
setting;
it
assigns
the
serial
port
to
the
BMC
exclusively.
-
BMC
Serial
Port
Access
Mode
If
serial-port
sharing
is
enabled,
specify
the
times
and
conditions
during
which
the
BMC
shares
the
serial
port.
-
Reboot
System
on
NMI
Enable
or
disable
restarting
the
system
whenever
a
nonmaskable
interrupt
(NMI)
occurs.
Disabled
is
the
default.
-
BMC
Network
Configuration
View
the
BMC
MAC
address
and
the
current
BMC
IP
address.
Define
the
static
BMC
IP
address,
subnet
mask,
and
gateway
address,
and
specify
whether
to
use
the
static
IP
address
or
have
DHCP
assign
the
BMC
IP
address.
-
BMC
System
Event
Log
Select
this
choice
to
view
the
BMC
system
event
log,
which
contains
messages
about
system
events,
such
as
devices
that
have
been
installed
or
removed
or
a
threshold
that
has
been
reached.
Select
Clear
BMC
SEL
to
clear
the
BMC
system
event
log.
-
User
Account
Settings
Define
user
names
and
passwords
for
logging
in
to
the
BMC
to
remotely
control
settings
in
the
server,
such
as
power
settings.
v
Event/Error
Logs
Select
this
choice
to
view
and
clear
the
POST
error
log
and
the
system
event/error
log.
–
Post
Error
Log
Select
this
choice
to
view
the
three
most
recent
error
codes
and
messages
that
were
generated
during
POST.
Select
Clear
POST
Error
Log
to
clear
the
POST
error
log.
–
System
Event/Error
Log
This
choice
is
available
only
if
an
optional
Remote
Supervisor
Adapter
II
SlimLine
is
installed.
Select
this
choice
to
view
the
error
messages
in
the
system
event/error
log.
You
can
use
the
arrow
keys
to
move
between
pages
in
the
error
log.
Select
Clear
System
Event/Error
Log
to
clear
the
system
event/error
log.
The
system
event/error
log
contains
all
event
and
error
messages
that
have
been
generated
during
POST,
by
the
system
management
interface
handler,
and
by
the
system
service
processor.
Run
the
diagnostic
programs
to
get
more
information
about
error
codes
that
occur.
See
the
Problem
Determination
and
Service
Guide
on
the
IBM
Documentation
CD
for
instructions
for
running
the
diagnostic
programs.
v
Save
Settings
Select
this
choice
to
save
the
changes
that
you
have
made
in
the
settings.
v
Restore
Settings
Select
this
choice
to
cancel
the
changes
that
you
have
made
in
the
settings
and
restore
the
previous
settings.
v
Load
Default
Settings
Chapter
3.
Configuring
the
server
53
Содержание 79788BU
Страница 1: ...IBM System x3550 Type 7978 User s Guide...
Страница 2: ......
Страница 3: ...IBM System x3550 Type 7978 User s Guide...
Страница 30: ...16 IBM System x3550 Type 7978 User s Guide...
Страница 62: ...48 IBM System x3550 Type 7978 User s Guide...
Страница 100: ...86 IBM System x3550 Type 7978 User s Guide...
Страница 101: ......
Страница 102: ...Part Number 42C4977 Printed in USA 1P P N 42C4977...