The
following
controls
and
LEDs
are
on
the
operator
information
panel:
–
Power-on
LED:
When
this
green
LED
is
lit
and
not
flashing,
it
indicates
that
the
server
is
turned
on.
When
this
LED
is
flashing,
it
indicates
that
the
server
is
turned
off
and
is
still
connected
to
an
ac
power
source.
When
this
LED
is
off,
it
indicates
that
ac
power
is
not
present,
or
the
power
supply
or
the
LED
itself
has
failed.
A
power
LED
is
also
on
the
rear
of
the
server.
Note:
If
this
LED
is
off,
it
does
not
mean
that
there
is
no
electrical
power
in
the
server.
The
LED
might
be
burned
out.
To
remove
all
electrical
power
from
the
server,
you
must
disconnect
the
power
cord
from
the
electrical
outlet.
–
System-locator
LED:
Use
this
blue
LED
to
visually
locate
the
server
among
other
servers.
You
can
use
IBM
Director
to
light
this
LED
remotely.
This
LED
is
controlled
by
the
BMC.
–
System-error
LED:
When
this
amber
LED
is
lit,
it
indicates
that
a
system
error
has
occurred.
A
system-error
LED
is
also
on
the
rear
of
the
server.
An
LED
on
the
light
path
diagnostics
panel
on
the
system
board
is
also
lit
to
help
isolate
the
error.
This
LED
is
controlled
by
the
BMC.
–
Release
latch:
Press
the
release
latch
to
the
left
to
slide
out
the
operator
information
panel
and
view
the
light
path
diagnostics
LEDs
and
buttons.
See
the
Problem
Determination
and
Service
Guide
for
more
information
about
the
light
path
diagnostics
panel.
–
System-information
LED:
When
this
amber
LED
is
lit,
it
indicates
that
a
noncritical
event
has
occurred.
Check
the
error
log
for
additional
information.
See
the
information
about
light
path
diagnostics
in
the
Problem
Determination
and
Service
Guide
for
more
information
about
error
logs.
–
Hard
drive
activity
LED:
When
this
green
LED
is
lit,
it
indicates
that
one
of
the
hard
disk
drives
is
in
use.
Notes:
1.
For
a
SAS
drive,
a
hard
disk
drive
activity
LED
is
shown
in
two
places:
on
the
hard
disk
drive
and
on
the
operator
information
panel.
2.
For
a
SATA
drive,
hard
disk
drive
activity
is
indicated
only
by
the
hard
disk
drive
activity
LED
on
the
operator
information
panel.
–
Power-control
button:
Press
this
button
to
turn
the
server
on
and
off
manually.
v
Rack
release
latches:
Press
the
latches
on
each
front
side
of
the
server
to
remove
the
server
from
the
rack.
v
Video
connector:
Connect
a
monitor
to
this
connector.
The
video
connectors
on
the
front
and
rear
of
the
server
can
be
used
simultaneously.
v
USB
connectors:
Connect
a
USB
device,
such
as
a
USB
mouse,
keyboard,
or
other
device
to
any
of
these
connectors.
v
CD-RW/DVD
eject
button:
Press
this
button
to
release
a
DVD
or
CD
from
the
CD/DVD
drive.
v
CD-RW/DVD
drive
activity
LED:
When
this
LED
is
lit,
it
indicates
that
the
CD-RW/DVD
drive
is
in
use.
v
Hard
disk
drive
status
LED:
This
LED
is
used
on
SAS
hard
disk
drives.
When
this
LED
is
lit,
it
indicates
that
the
drive
has
failed.
If
an
optional
IBM
ServeRAID
controller
is
installed
in
the
server,
when
this
LED
is
flashing
slowly
(one
flash
per
second),
it
indicates
that
the
drive
is
being
rebuilt.
When
the
LED
is
flashing
rapidly
(three
flashes
per
second),
it
indicates
that
the
controller
is
identifying
the
drive.
Chapter
1.
The
System
x3550
Type
7978
server
11
Содержание 79788BU
Страница 1: ...IBM System x3550 Type 7978 User s Guide...
Страница 2: ......
Страница 3: ...IBM System x3550 Type 7978 User s Guide...
Страница 30: ...16 IBM System x3550 Type 7978 User s Guide...
Страница 62: ...48 IBM System x3550 Type 7978 User s Guide...
Страница 100: ...86 IBM System x3550 Type 7978 User s Guide...
Страница 101: ......
Страница 102: ...Part Number 42C4977 Printed in USA 1P P N 42C4977...