Figure 51. ServeRAID M5000 advanced feature key installation
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on
.
Installing a hot-swap fan assembly
Use this information to install a hot-swap fan assembly.
The server comes standard with five dual-motor hot-swap cooling fans.
Attention:
To ensure proper operation, replace a failed hot-swap fan within 30 seconds.
To install an additional hot-swap fan, complete the following steps:
Step 1. Read the safety information that begins on
“Installation guidelines” on page
Step 2. Remove the cover (see
“Removing the cover” on page 48
).
Step 3. Touch the static-protective package that contains the new fan to any unpainted metal surface on
the server. Then, remove the new fan from the package.
.