Table 4. Light path diagnostics panel LEDs (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See “Parts listing” to determine which components are customer replaceable units (CRU) and which
components are field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only)”, that step must be performed only by a
trained service technician.
LED
Description
Action
OVER SPEC
(Continued)
The power supplies are using
more power than their maximum
rating.
If the 12 V channel C error LED is lit, complete the following
steps:
1. Turn off the server and disconnect the power from the
server.
2. Remove the SAS/SATA RAID riser card, DIMMs in
connectors 1 through 9, and the microprocessor in socket
1.
Note:
The server will not power-on when the
microprocessor in socket 1 or 2 is not installed in the
server. (Trained service technician only) Toggle the switch
block (SW4), bit 3 to allow the server to power-on. See
“System-board switches and jumpers” on page 36
for the
location of the SW4 switch block on the system board.
3. Restart the server to see whether the problem remains.
4. Reinstall each device that you removed in step 2 one at a
time, starting the server each time, to isolate the failing
device.
5. Replace any failing device.
6. (Trained service technician only) Replace the system
board.
If the 12 V channel D error LED is lit, complete the following
steps:
1. Turn off the server and disconnect the power from the
server.
2. (Trained service technician only) Remove the
microprocessor in socket 1.
Note:
The server will not power-on when the
microprocessor in socket 1 or 2 is not installed in the
server. (Trained service technician only) Toggle the switch
block (SW4), bit 3 to allow the server to power-on. See
“System-board switches and jumpers” on page 36
for the
location of the SW4 switch block on the system board.
3. Restart the server to see whether the problem remains.
4. (Trained service technician only) Reinstall the
microprocessor in socket 1 and restart the server.
5. Replace any failing device.
6. (Trained service technician only) Replace the system
board.
(Continued on the next page.)
The Lenovo System x3550 M3 server
19
Содержание 7944
Страница 1: ...System x3550 M3 Installation and User s Guide Machine Type 4254 and 7944...
Страница 44: ...Figure 14 Server components 34 System x3550 M3Installation and User s Guide...
Страница 114: ...104 System x3550 M3Installation and User s Guide...
Страница 132: ...122 System x3550 M3Installation and User s Guide...
Страница 136: ...126 System x3550 M3Installation and User s Guide...
Страница 148: ...138 System x3550 M3Installation and User s Guide...
Страница 149: ......
Страница 150: ...Part Number 00KC032 Printed in China 1P P N 00KC032 1P00KC032...