Ring Detection
Most modems produce an interrupt request each time they detect a ring signal. Some
modems generate an interrupt only on the first ring signal that they receive. AT&T
DataPort 2001 is an example of such a modem.
The service processor uses the ring interrupt request to count the number of rings when
Ring Indicate Power-On (RIPO) is enabled. If your modem produces an interrupt on
only the first ring, set Ring Indicate Power-On to start on the first ring. Otherwise, you
can choose to start Ring Indicate Power-On on any ring count.
Terminal Emulators
The service processor is compatible with simple ASCII terminals, and therefore
compatible with most emulators. When a remote session is handed off from the service
processor to the operating system, agreement between terminal emulators becomes
important.
The server’s operating system will have some built-in terminal emulators. You may also
have a commercially available terminal emulation. It is important that the local and host
computers select the same or compatible terminal emulators so that the key
assignments and responses match, ensuring successful communications and control.
For best formatting, choose line wrap in your terminal emulator setup.
Recovery Procedures
Situations such as line noises and power surges can sometimes cause your modem to
enter an undefined state. When it is being used for dial-in, dial-out or ring indicate
power-on, your modem is initialized each time one of these actions is expected. If one
of these environmental conditions occur after your modem has been initialized, it might
be necessary to recover your modem to a known state.
If your modem communicates correctly with remote users, it is probably in control. It
may be wise to occasionally change some of the functional settings and then change
them back, just for the sense of security that the modem is communicating, and to
ensure it has been initialized recently.
If your system is particularly difficult to access physically, another strategy is to protect it
with an Uninterruptible Power Source (UPS) and a phone-line surge protector.
In case recovery becomes necessary, shut down your system using established
procedures. Disconnect the power cable and press the power button to drain
capacitance while power is disconnected. Disconnect and reconnect modem power, and
then reconnect system power to completely reinitialize your system.
330
Service Guide
Содержание 6C1
Страница 1: ...pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ERserver IBM ...
Страница 2: ......
Страница 3: ...pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ERserver IBM ...
Страница 14: ...xii Service Guide ...
Страница 16: ...xiv Service Guide ...
Страница 25: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 Chapter 1 Reference Information 7 ...
Страница 52: ...34 Service Guide ...
Страница 102: ...84 Service Guide ...
Страница 129: ...5 Turn the power off then on and retry the boot operation Chapter 4 Checkpoints 111 ...
Страница 234: ...216 Service Guide ...
Страница 299: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 281 ...
Страница 322: ...System Parts 1 2 3 4 5 6 7 8 9 10 16 17 18 11 12 13 14 15 19 21 20 22 23 24 25 26 28 27 304 Service Guide ...
Страница 324: ...1 2 3 4 5 6 306 Service Guide ...
Страница 338: ...320 Service Guide ...
Страница 342: ...324 Service Guide ...
Страница 366: ...348 Service Guide ...
Страница 375: ......
Страница 376: ...IBMR Printed in U S A February 2002 SA38 0599 01 ...
Страница 377: ...Spine information IBM pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ...