Step 1540-27
The last FRU installed or one of its attached devices is probably defective.
1. Turn off the power.
2. Remove the power cords.
3. Starting with the last installed adapter, disconnect one attached device and cable.
4. Plug in the power cords and wait for OK on the operator panel display.
5. Turn on the power.
6. If the Console Selection screen is displayed, choose the firmware console.
7. Enter the appropriate password if you are prompted to do so.
Does the system stop with the same error code displayed on the operator panel
that directed you to this MAP step?
NO
The last device or cable that you disconnected is defective.
Exchange the defective device or cable.
Go to
″
MAP 0410: Repair Checkout
″
in the
RS/6000
Eserver
pSeries
Diagnostic Information for Multiple Bus Systems.
YES
Repeat this step until the defective device or cable is identified or all of the
devices and cables have been disconnected.
If all of the devices and cables have been removed, then one of the FRUs
remaining in the system unit is defective.
To test each FRU, exchange the FRUs in the following order:
1. Adapter (last one installed)
2. System board (see notes on page 35)
Go to
″
MAP 0410: Repair Checkout
″
in the
RS/6000
Eserver
pSeries
Diagnostic Information for Multiple Bus Systems.
If the symptom did not change and all the FRUs have been exchanged, return
to “Step 1540-2” on page 65 in this MAP.
Chapter 3. Maintenance Analysis Procedures (MAPs)
83
Содержание 6C1
Страница 1: ...pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ERserver IBM ...
Страница 2: ......
Страница 3: ...pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ERserver IBM ...
Страница 14: ...xii Service Guide ...
Страница 16: ...xiv Service Guide ...
Страница 25: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 Chapter 1 Reference Information 7 ...
Страница 52: ...34 Service Guide ...
Страница 102: ...84 Service Guide ...
Страница 129: ...5 Turn the power off then on and retry the boot operation Chapter 4 Checkpoints 111 ...
Страница 234: ...216 Service Guide ...
Страница 299: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 281 ...
Страница 322: ...System Parts 1 2 3 4 5 6 7 8 9 10 16 17 18 11 12 13 14 15 19 21 20 22 23 24 25 26 28 27 304 Service Guide ...
Страница 324: ...1 2 3 4 5 6 306 Service Guide ...
Страница 338: ...320 Service Guide ...
Страница 342: ...324 Service Guide ...
Страница 366: ...348 Service Guide ...
Страница 375: ......
Страница 376: ...IBMR Printed in U S A February 2002 SA38 0599 01 ...
Страница 377: ...Spine information IBM pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ...