Table 3. Firmware Error Codes. (continued)
Error Code Description
Action / Possible Failing FRU
Memory Error Notes
Use the location code obtained from the SMS Error Log utility (described in “Step 1020-4” on
page 48) to identify which memory DIMM (or memory DIMM pair) the error is reported against.
Memory error codes are in the form 25Cyyxxx where yy indicates memory DIMM present
detect-bits (PD-bits) and xxx indicates the last 3 digits of the error code.
See Table 4 on page 176 for information on how to interpret PD bits.
25B00001 No memory DIMMs detected.
Go to “MAP 1240: Memory Problem
Resolution” on page 49.
25B00002 Multiple memory DIMMs failed a memory
test.
Go to “MAP 1240: Memory Problem
Resolution” on page 49.
25Cyy001 Memory DIMM is not supported.
Replace unsupported memory DIMM.
Note:
Memory DIMM must be replaced with
a supported type of memory DIMM. If
an unsupported memory DIMM is
replaced with the same unsupported
type, the error persists.
There might be two memory
module-related memory errors
reported to indicate a memory DIMM
pair. One of the two indicated memory
DIMMs may be good. When replacing
memory replace one memory DIMM at
a time, not both.
See Memory Error Notes on page 126
for more information.
25Cyy002 Memory DIMM fails memory test.
Go to “MAP 1240: Memory Problem
Resolution” on page 49.
25Cyy003 PD bits are mismatched or missing one
memory DIMM.
1. Make sure both memory DIMMs in
the pair are present and are the
same type.
2. Go to “MAP 1240: Memory
Problem Resolution” on page 49.
25Cyy004 Memory DIMMs are disabled.
1. Use the memory config/deconfig
menu in the Service Processor
System Information Menu to check
the status of the memory DIMMs.
2. Go to “MAP 1240: Memory
Problem Resolution” on page 49.
25Cyy005 Memory DIMM failed address test.
Go to “MAP 1240: Memory Problem
Resolution” on page 49.
126
Service Guide
Содержание 6C1
Страница 1: ...pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ERserver IBM ...
Страница 2: ......
Страница 3: ...pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ERserver IBM ...
Страница 14: ...xii Service Guide ...
Страница 16: ...xiv Service Guide ...
Страница 25: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 Chapter 1 Reference Information 7 ...
Страница 52: ...34 Service Guide ...
Страница 102: ...84 Service Guide ...
Страница 129: ...5 Turn the power off then on and retry the boot operation Chapter 4 Checkpoints 111 ...
Страница 234: ...216 Service Guide ...
Страница 299: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 281 ...
Страница 322: ...System Parts 1 2 3 4 5 6 7 8 9 10 16 17 18 11 12 13 14 15 19 21 20 22 23 24 25 26 28 27 304 Service Guide ...
Страница 324: ...1 2 3 4 5 6 306 Service Guide ...
Страница 338: ...320 Service Guide ...
Страница 342: ...324 Service Guide ...
Страница 366: ...348 Service Guide ...
Страница 375: ......
Страница 376: ...IBMR Printed in U S A February 2002 SA38 0599 01 ...
Страница 377: ...Spine information IBM pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ...