Service Processor Checkpoints
Service processor checkpoints are in the range E010 to E0FF. The message OK
indicates successful service processor testing and initialization. Firmware checkpoints
are listed in “Firmware Checkpoints” on page 92.
If you replace FRUs or perform an action, and the problem is still unresolved, go to
“MAP 1540: Minimum Configuration” on page 63 unless otherwise indicated in the
tables.
If you replace FRUs or perform an action, and the problem is corrected, go to
″
MAP
0410: Repair Checkout
″
in the
RS/6000
Eserver
pSeries Diagnostic Information for
Multiple Bus Systems.
Table 1. Service Processor Checkpoints.
Checkpoint
Description
Action/ Possible Failing FRU
DIAG STBY
Service processor is ready. The system
unit was shut down in service mode by
the operating system; however, the
system unit is still powered on.
The service processor is ready. The
operating system has been terminated;
the system is still powered on. This
usually indicates an operating system
crash. The service processor menus are
available. Look for error codes related
to the operating system crash in the
service processor error log.
E000
System support controller begins
operation. This is an informational
checkpoint.
Call support.
E010
Starting service processor self-tests
Replace the system board.
Location: P1
(See note 3 on page 115.)
E011
Service processor self-tests completed
successfully
Call support.
E012
Begin to set up service processor helps
Replace the system board.
Location: P1
(See note 3 on page 115.)
E020
Configuring CMOS
Replace the system board.
Location: P1
(See note 3 on page 115.)
E021
Configuring NVRAM
1. Manually drain the NVRAM by
removing the battery. Short circuit
the battery leads for at least 30
seconds. Use a conductive object
such as a coin or a screwdriver for
this purpose.
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
E022
Accessing system board VPD
Replace the system board.
Location: P1
(See note 3 on page 115.)
86
Service Guide
Содержание 6C1
Страница 1: ...pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ERserver IBM ...
Страница 2: ......
Страница 3: ...pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ERserver IBM ...
Страница 14: ...xii Service Guide ...
Страница 16: ...xiv Service Guide ...
Страница 25: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 Chapter 1 Reference Information 7 ...
Страница 52: ...34 Service Guide ...
Страница 102: ...84 Service Guide ...
Страница 129: ...5 Turn the power off then on and retry the boot operation Chapter 4 Checkpoints 111 ...
Страница 234: ...216 Service Guide ...
Страница 299: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 281 ...
Страница 322: ...System Parts 1 2 3 4 5 6 7 8 9 10 16 17 18 11 12 13 14 15 19 21 20 22 23 24 25 26 28 27 304 Service Guide ...
Страница 324: ...1 2 3 4 5 6 306 Service Guide ...
Страница 338: ...320 Service Guide ...
Страница 342: ...324 Service Guide ...
Страница 366: ...348 Service Guide ...
Страница 375: ......
Страница 376: ...IBMR Printed in U S A February 2002 SA38 0599 01 ...
Страница 377: ...Spine information IBM pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ...