Table 3. Firmware Error Codes. (continued)
Error Code Description
Action / Possible Failing FRU
20D0000F Self-test failed on device, no
error/location code information available.
Check the System Management
Services error log entry (described in
“Step 1020-4” on page 48) for this
error code. The location code (if
present) in the error log entry should
identify the location of the failing
device.
20D00010 Self-test failed on device, cannot locate
package.
Contact your service support
representative for assistance.
20D00011 Instantiate RTAS failed.
Contact your service support person
for assistance.
20E00000 Power-on password entry error.
The password has been entered
incorrectly.
Re-enter the password.
20E00001 Privileged-access password entry error.
The password has been entered
incorrectly.
Re-enter the password.
20E00002 Privileged-access password jumper not
enabled.
The privileged-access password
jumper is not in the correct position for
password initial entry.
Consult the system’s User’s Guide for
jumper location and position.
20E00003 Power-on password must be set for
unattended mode.
Unattended mode requires the setting
of the power-on password before it is
enabled.
20E00004 Battery drained or needs replacement.
1. Replace battery.
Location: P1-V2
2. Replace the system board.
Location: P1
(See notes on page 115.)
20E00008 CMOS corrupted or tampering evident,
CMOS initialized.
1. Replace battery, restore NVRAM
data (passwords, startup data).
Location: P1-V2
2. Replace the system board.
Location: P1
(See notes on page 115.)
20E00009 Invalid password entered - system
locked.
The password has been entered
incorrectly 3 times.
Turn off, then turn on the system unit,
then enter the password correctly.
20E0000C Failed to open RTC device tree node.
1. Turn off, turn on system unit.
2. Replace the system board.
Location: P1
(See notes on page 115.)
Chapter 5. Error Code to FRU Index
117
Содержание 6C1
Страница 1: ...pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ERserver IBM ...
Страница 2: ......
Страница 3: ...pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ERserver IBM ...
Страница 14: ...xii Service Guide ...
Страница 16: ...xiv Service Guide ...
Страница 25: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 Chapter 1 Reference Information 7 ...
Страница 52: ...34 Service Guide ...
Страница 102: ...84 Service Guide ...
Страница 129: ...5 Turn the power off then on and retry the boot operation Chapter 4 Checkpoints 111 ...
Страница 234: ...216 Service Guide ...
Страница 299: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 281 ...
Страница 322: ...System Parts 1 2 3 4 5 6 7 8 9 10 16 17 18 11 12 13 14 15 19 21 20 22 23 24 25 26 28 27 304 Service Guide ...
Страница 324: ...1 2 3 4 5 6 306 Service Guide ...
Страница 338: ...320 Service Guide ...
Страница 342: ...324 Service Guide ...
Страница 366: ...348 Service Guide ...
Страница 375: ......
Страница 376: ...IBMR Printed in U S A February 2002 SA38 0599 01 ...
Страница 377: ...Spine information IBM pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ...