Chapter 5
Unix Troubleshooting Tips
126
To add/delete a TCP access list entry, refer to “TCP Access Lists”
on page 287.
NOTE: When the following procedure is used, the TCP access list
will be cleared, but all IP addresses will need to be entered
again after the procedure is complete.
To reset all TCP/IP values to the factory defaults when access is
impossible:
1.
Obtain a configuration printout using the control panel. See the
4400 User's Manual for configuration menu information.
2.
Power off the printer.
3.
On the Ethernet Interface, place SWITCH 1 in the down
position.
4.
Power on the printer and wait for the ONLINE state.
5.
On the Ethernet Interface, place SWITCH 1 in the up position.
6.
From a workstation attached to this network segment, create
an ARP entry. The Ethernet Interface IP address and hardware
or MAC address are needed. At the workstation enter:
arp -s <ipaddress> <MACaddress>
ping <ipaddress>
7.
Try to
ping
this IP address to see if the Ethernet Interface can
be seen on your network. If the interface does not respond,
verify you are on the same network segment as the printer and
that the ARP entry was created.
8.
Telnet
into the Ethernet Interface using the same IP address
as above. Log in as
root
with no password.
9.
At the system prompt, enter:
store tcpip from default
SMART
config http on
reset
NOTE: This will reset all TCP/IP settings to factory default and
reset the Ethernet Interface.
Содержание 4400-006 - 4400 Model 006 B/W Direct Thermal
Страница 2: ......
Страница 3: ...G544 5769 03 User s Manual 4400 Series Thermal Printer Basic And Smart Ethernet Interface...
Страница 14: ...Table of Contents...
Страница 30: ...Chapter 1 Interfaces 30...
Страница 48: ...Chapter 3 Network Configuration 48 Novell Network Figure 8 Novell Network Configuration...
Страница 72: ...Chapter 3 IBM Printing Systems 72...
Страница 90: ...Chapter 4 Windows Host Configuration 90 8 Select Custom and click Settings...
Страница 92: ...Chapter 4 Windows Host Configuration 92 10 Click Next 11 Click Finish...
Страница 94: ...Chapter 4 Windows Host Configuration 94 14 Select Yes then click Next 15 Click Next...
Страница 108: ...Chapter 4 Windows Troubleshooting Tips 108...
Страница 128: ...Chapter 5 Unix Troubleshooting Tips 128...
Страница 184: ...Chapter 8 OS 2 Workstation Configuration 184...
Страница 200: ...Chapter 9 AS 400 ASCII Troubleshooting 200...
Страница 242: ...Chapter 11 Handling MVS Connectivity Problems 242...
Страница 256: ...Chapter 13 Monitoring Tools 256...
Страница 284: ...Chapter 15 Complete Command List 284...
Страница 292: ...Chapter 16 Ethernet Interface Naming Schemes 292...
Страница 304: ...Communication Statements 304...
Страница 310: ...Chapter 310...
Страница 322: ...Index 322...
Страница 325: ......
Страница 326: ...175331 001B G544 5769 03 07G544576903 1P P N 75P2507 1P75P2507 175331 001 Part Number 75P2507 Printed in U S A...