6. The following message will be displayed:
T&D10 Bidirectional Adjustment Test STORE YES ... NO
7. If the bidirectional adjustment printout is correct, press the Line Feed key to store the value.
8. If the bidirectional adjustment printout is not correct, press the Start key to view the next display:
T&D10 Bidirectional Adjustment Test VERT. ADJ. 0 + RUN -
9. Press the Line Feed key once to shift the bottom row of Is to the right, or the Start key to shift the
bottom row of Is to the left. The value changes on the operator panel display.
10. Press the Form Feed key to repeat step 6.
11. If an error message is displayed, go to T&D error messages and actions.
12. The test completed successfully if the display advances to the next test number.
T&D11—Tear-off line adjustment test
This test allows you to adjust the tear-off position from the operator panel.
The value set by this test becomes the tear-off position when the configuration menu item
Tear Adjustment
is set
to
0
at the operator panel.
1. Display:
T&D11 Tear-Off Line Adjustment Test RUN TEST ? YES END NO
2. Press the Line Feed key.
Chapter 2. Diagnostics
113
Содержание 4247-V03
Страница 24: ...Reference table 8 ribbon lift and 26 pin cable connectors 93 Chapter 1 Diagnosing problems 24 ...
Страница 138: ...Operator panel cable wiring Chapter 3 Wiring diagrams 138 ...
Страница 144: ...Tractor assembly cable wiring Chapter 3 Wiring diagrams 144 ...
Страница 164: ...Chapter 5 Removals service checks and adjustments 164 ...
Страница 173: ...Table 24 Print quality sample 1 2 3 Chapter 5 Removals service checks and adjustments 173 ...
Страница 246: ...Assemblies Chapter 6 Parts catalog 246 ...
Страница 307: ...Taiwanese EMC Notices 307 ...
Страница 310: ...Index Copyright IBM Corp 2002 310 ...
Страница 311: ...IBMR Part Number 75P1301 Printed in U S A G544 5873 00 1P P N 75P1301 ...