![IBM 3746-900 Скачать руководство пользователя страница 216](http://html2.mh-extra.com/html/ibm/3746-900/3746-900_installation-manual_3317305216.webp)
Removal the 3746-900 Attached to a 3745-17A
Go through the following procedures sequentially.
Updating the Service Processor Network Configuration
Step
1. ____ Modify the mainstream error reporting to NetView (if necessary).
Step
2. ____ If not logged on, enter the Service Processor maintenance pass-
word (default password IBM3745).
Note: If you have a power allegiance recorded for the 3746-900 (to
verify, display the 3746-900 status), remove it using the "Manage
MOSS-E Power Allegiance" function before trying to remove the
3746-900.
Step
3. ____ Double click on the "Service Processor Object Icon".
Step
4. ____ Click on "Configuration Management".
Step
5. ____ Double click on "Manage 3745/3746-9x0 installation/removal".
Step
6. ____ Select the 3746-900 to be removed.
Step
7. ____ Click on "Save" and insert the 3746-900 installation parameters
diskette to save the data.
Note: This diskette must be shipped with the machine.
Step
8. ____ Re-select the 3746-900 to be removed and click on "Remove".
Step
9. ____ Check and confirm the delete option. At the end, the Service
Processor is reinitialized.
Disconnecting the Mainline Power
Step
1. ____ At the control panel, ensure that the Power Control window displays
'3' (Local), and push the Standby key.
Step
2. ____ Switch the main circuit breaker CB1 OFF at the 3746-900 primary
power box. (See Figure B-12 on page B-9 or Figure B-13 on page B-9,
if the optional power feature is installed)
Step
3. ____ Ensure that the customer's branch-circuit breakers, feeding the
3746-900 receptacle, are turned OFF.
Step
4. ____ Unplug the 3746-900 main power cable, or ask the customer to dis-
connect the 3746-900 power cable from its ac power receptacle (or dc
power, if any).
Step
5. ____ Coil the disconnected power cable inside the 3746-900.
Disconnecting the Interface Cables
Step
1. ____ If the machines are being relocated, label and remove all data set
cables from the TRA, ESCA, and CLA adapters.
Note: It is advisable to disconnect the cables starting at the top of the
gate (board 01D-A1), and working down.
Step
2. ____ Remove the cable (PN 76F9440 or 76F9441) from the 8228 LAN
adapter to the 3746-900 01N-A1 F1.
13-2
3746-900: Installation Guide
Содержание 3746-900
Страница 1: ...3746 Nways Multiprotocol Controller Model 900 IBM Installation Guide SY33 2114 03...
Страница 2: ......
Страница 3: ...3746 Nways Multiprotocol Controller Model 900 IBM Installation Guide SY33 2114 03...
Страница 14: ...xii 3746 900 Installation Guide...
Страница 17: ...Notices xv...
Страница 20: ...7 Power ON indicator 8 Emergency power OFF xviii 3746 900 Installation Guide...
Страница 24: ...xxii 3746 900 Installation Guide...
Страница 26: ...xxiv 3746 900 Installation Guide...
Страница 40: ...3746 900 preparing for installation 1 14 3746 900 Installation Guide...
Страница 102: ...3746 900 Test Procedure 3 14 3746 900 Installation Guide...
Страница 146: ...Cabling the 3746 900 to the 3745 X1A 4 44 3746 900 Installation Guide...
Страница 168: ...3745 Test Procedures 7 6 3746 900 Installation Guide...
Страница 198: ...3746 900 Ground Bracket Installation 9 6 3746 900 Installation Guide...
Страница 204: ...3746 900 Attached to a 3745 17A Ground Bracket Installation 10 6 3746 900 Installation Guide...
Страница 205: ...Machine Ready for Customer Chapter 11 Making the Machine Ready for the Customer Copyright IBM Corp 1996 1997 11 1...
Страница 210: ...Machine Ready for Customer 11 6 3746 900 Installation Guide...
Страница 218: ...Removal the 3746 900 Attached to a 3745 17A 13 4 3746 900 Installation Guide...
Страница 220: ...A 2 3746 900 Installation Guide...
Страница 250: ...E 14 3746 900 Installation Guide...
Страница 268: ...X 18 3746 900 Installation Guide...
Страница 272: ......
Страница 275: ......
Страница 276: ...IBM Part Number 29H4858 Printed in Denmark by IBM Danmark A S 29H4858 SY33 2114 3...