AS1041TC-CL
Page
16
water is supplied to the plumbing system. (Figure
2)
3.
Diagnostic Position
: The inlet handle points in
the direction of flow and the outlet handle points
to the centre of bypass valve, system water
pressure is allowed to the control valve and the
plumbing system while not allowing water to exit
from the control valve to the plumbing.(Figure 3)
4.
Shut Off Position:
The inlet handle points to the
centre of the bypass valve and the outlet handle
points in the direction of flow, the water is shut off
to the plumbing system (i.e. plumbing connection
somewhere in the building bypasses the system).
(Figure 4)