![IBC Water AST1041TC-CL Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/ibc-water/ast1041tc-cl/ast1041tc-cl_installation-and-operating-instructions-manual_3240021002.webp)
AS1041TC-CL
Page
2
Time Clock
Model No.
Capacity & Salt
Dosage
Recommended
Maximum
Service Flow
Rate
Pipe Size
Resin
Volume
Approx.
Shipping
Weight
(kg)
Space
Required
Minimum
Maximum
Inlet
Outlet
Drain
W x D x H
gram/kg
gram/kg
Flow
LPM
mm
mm
Litres
Per Kg
metres
AST1041TC-CL
1435/3.0
2870/10.0
41
25BSP
”F”
12
41
60
0.7
0.6
1.58
CABINET/
BRINE CHAMBER: POLY MOULDED
System Operating Pressure:
330 - 690 kPa
Temperature:
4
o
x 43
o
C
Electrical:
240V—16VAC 50Hz 3 watts maximum
Control Valve:
Series WS1-TC with bypass valve and installation fittings.
WARNING
A pressure reduction valve must be installed in areas of high water pressure (above 690kPa)
A water hammer arrestor must be installed if water hammer prevails, between the softener and the
closing off device.
Caution: Do not use where water is microbiologically unsafe or with water of unknown quality.
FAILURE TO OBSERVE WARNINGS WILL VOID WARRANTY
GENERAL WATER SOFTENER
PERFORMANCE DATA SHEET
Содержание AST1041TC-CL
Страница 3: ...AS1041TC CL Page 3...
Страница 7: ...AS1041TC CL Page 7 Note Maximum number of days that can be selected is 99...
Страница 23: ...AS1041TC CL Page 23 SPARE PARTS AND SERVICING INSTRUCTIONS...
Страница 31: ...AS1041TC CL Page 31 10 V3156 O ring 214 2 Flow Diagrams Service and Backwash flow diagram service...
Страница 32: ...AS1041TC CL Page 32 flow diagram backwash Flow Diagram Down flow Brine...
Страница 33: ...AS1041TC CL Page 33 flow diagram downflow brine Flow Diagrams Rinse and Fill...
Страница 34: ...AS1041TC CL Page 34 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01...
Страница 41: ...AS1041TC CL Page 41...
Страница 42: ...AS1041TC CL Page 42 Troubleshooting...