Important Installation Details 

 
The control valve, fittings and/or bypass are designed 
to  accommodate  minor  plumbing  misalignments  but 
are  not  designed  to  support  the  weight of the system 
or the plumbing. 
 
Do no use Vaseline, oils, other hydrocarbon lubricants 
or  spray  silicone  anywhere.    A  silicone  lubricant  may 
be used on black o-rings but is not necessary.  

Avoid 

any  type  of  lubricants,  including  silicone,  on  the 
clear lip seals. 

 
The  nuts  and  caps  are  designed  to  be  unscrewed  or 
tightened  by  hand  or  with  the  special  plastic  wrench.   
Do not use a pipe wrench to tighten or loosen nuts or 
caps.  Do not place a screwdriver in the slots on caps 
and/or tap with a hammer. 
 
Do  not  use  pipe  dope  or  other  sealant  on  threads.  
Use  teflon  tape  on  threaded  inlet,  outlet  and  drain 
fittings.Teflon  tape  is  not  necessary  on  the  nut 
connection or caps because of o-ring seals. 
 

After completing any valve maintenance involving 
the  drive  assembly  of  the  drive  camp  assembly 
and  pistons,  unplug  power  source  jack  from  the 
circuit  board  (black  wire)  and  plug  back  in

.    This 

resets  the  electronics  and  establishes  the  service 
piston  position.  The  display  should  flash  and  then 
reset the valve to the service position if necessary. 
 
All plumbing should be done in accordance with local 
plumbing  codes.  The  pipe  size  for  the  drain  line 
should be a minimum of 12mm inside diameter.  
   
Solder  joints  near  the  drain  must  be  done  prior  to 
connecting the drain line flow control fitting.  Leave at 
least 150mm (6”) between the drain line control fitting 
and  solder  joints  when  soldering  pipes  that  are 
connected  on  the  drain  line  control  fitting.    Failure  to 
do  this  could  cause  interior  damage  to  the  drain  line 
flow control fitting. 
 
When assembling the installation fitting package (inlet 
and outlet), connect the fitting to the plumbing system 
first  and  then  attach  the  nut,  split  ring  and  o-ring.  
Heat from soldering or solvent cements may damage 
the  nut,  split  ring  and  o-ring.   Solder joints should be 
cool  and  solvent  cements  should  be  set  before 
installing  the  nut,  split  ring  or  o-ring.    Avoid  getting 
primer and solvent cement on any part of the o-rings, 
bypass valve or control valve. 
 
Position  the  softener  within  1½  metres  of  a  10  amp 
GPO.    The  transformer  is  connected  into  the  plug 
socket on the back of the valve control panel.  Do not 
drop the transformer or have the cable too taut.  The 
transformer  is  only  suitable  for 

internal  use  only

The softener must be weather protected. 

For  full  understanding  of  the  water  softener  we 
recommend  that  the  instruction  manual  be  fully  read 
before  installation  and  commissioning  of the softener 
by undertaken. 
 

IMPORTANT: 

NUMBER 

OF 

VALVE 

COMPONENTS  ARE  LOCKED  INTO  POSITION 
WITH 

EASILY 

REMOVABLE 

CLIPS

.              

ENSURE  ALL  LOCKING  CLIPS  ARE  CORRECTLY 
IN  POSITION  BEFORE  PRESSURISING  THE 
SOFTENER.  ENSURE  THAT  IT  IS  POINTED  OUT 
TO  ALL  RELEVANT  PERSONNEL  THAT  THE 
LOCKING  CLIPS  MUST  NOT  BE  REMOVED 
WHILST  THE  SYSTEM  IS  UNDER  WATER 
PRESSURE. 

 
Note:    All  electrical  connections  must  be  connected 
according to local codes. 
 
Install grounding strap on metal plates. 
 

Bypass Valve  

 
The  bypass  valve  is  typically  used  to  isolate  the 
control  valve  from  the  plumbing  system’s  water 
pressure  in  order  to  perform  control  valve  repairs  or 
maintenance.    The  WS1  bypass  valve  is  particularly 
unique  in  the  water  treatment  industry  due  to  its 
versatility  and  state  of  the  art  design  features.    The 
full  flow  bypass  valve  incorporates  four  positions, 
including  a  diagnostic  position  that  allows  service 
personnel  to  work  on  a  pressurised  system  while  still 
providing  untreated  bypass  water  to  the  facility  or 
residence.    Its  completely  non-metallic,  all  plastic 
design  allows  for  easy  access  and  serviceability 
without the need for tools. 
 
The  bypass  body  and  rotors  are  glass  filled  Noryl (or 
equivalent)  and  the  nuts  and  caps  are  glass  filled 
polypropylene.  All seals are self-lubricating EPDM to 
help  prevent  valve  seizing  after  long  periods  of  non-
use.  Internal o-rings can easily be replaced if service 
is required. 
 
The  bypass  consists  of  two  interchangeable  plug 
valves  that  are operated independently by red arrow-
shaped  handles.    The  handles  identify  the  flow 
direction  of  the  water.    The  plug  valves  enable  the 
bypass valve to operate in four positions. 
 
1. 

Normal Operation Position

:  The inlet and outlet 

handles point in the direction of flow indicated by 
the engraved arrows on the control valve.  Water 
flows  through  the  control  valve  during  normal 
operation and this position also allows the control 
valve  to  isolate  the  media  bed  during  the 
regeneration cycle. (Figure 1) 

2. 

Bypass  Position

:    The  inlet  and  outlet  handles 

point  to  the  centre  of  the  bypass,  the  control 
valve  is  isolated  from  the  water  pressure 
contained  in  the  plumbing  system.    Untreated 

Содержание AST1041TC-CL

Страница 1: ...PERATING INSTRUCTIONS Model AST1041TC CL Serial No Telephone 07 3219 2233 Facsimile 07 3219 2266 Email sales ibcwater com au Website www ibcwater com au FILTRATION WATER TREATMENT PRODUCTS for commerc...

Страница 2: ...perating Pressure 330 690 kPa Temperature 4 o x 43 o C Electrical 240V 16VAC 50Hz 3 watts maximum Control Valve Series WS1 TC with bypass valve and installation fittings WARNING A pressure reduction v...

Страница 3: ...AS1041TC CL Page 3...

Страница 4: ...the distributor pipe NEVER shorten the length of the distributor pipe STEP 6 Unpack control valve check that tank O ring is in place Fit the top strainer into the bottom of the valve if not already f...

Страница 5: ...mpleted 6 When used as above the tablets change the colour from green to red at a hardness of approximately 20ppm based on a sample volume of 10mls Other hardness test kits are available for more accu...

Страница 6: ...he number of days to be calculated 1 Raw Water Hardness in mg l call H 2 Maximum Water Softener Hardness Removal Capacity from Table 1 in grams page 2 call C 3 Estimated Daily Water Usage in litres ca...

Страница 7: ...AS1041TC CL Page 7 Note Maximum number of days that can be selected is 99...

Страница 8: ...generations Step 1ID To enter installer display press the SET HOUR and buttons simultaneously for approximately 5 seconds and release when 2 flashes This is the factory programmed Time Of Regeneration...

Страница 9: ...ONE then regeneration will take place at the next preset regeneration time The user can scroll between the displays as desired If the system has called for a regeneration at the preset time then an a...

Страница 10: ...Assemble the Strainer into the Valve by Matching Up the Locating Lugs and Twisting To Lock prior to the loading of the resin and screwing on the valve to the tank Note Never Shorten the Riser Pipe in...

Страница 11: ...nting Base 2 12 8 NPSM Height from Top of Tank 7 3 8 187mm Weight 4 5lbs 2kg Distributor Pilot 12mm Above Tank Top ELECTRICAL SPECIFICATIONS AC Adaptor Supply Voltage 230V AC Supply Frequency 50 Hz Ou...

Страница 12: ...ter Conditioner 15 General Cleaning the Injector Injector Screen Maintaining the Drain Line Brine Line and Brine Tank Overflow Connection 16 Placing Softener into Operation 17 Valve Manual 18 20 Repla...

Страница 13: ...ed at any time by pressing the buttons on the front panel It takes a few minutes for the regeneration to start The unit completes the regeneration in about two hours This feature is beneficial when yo...

Страница 14: ...e the unit to petroleum products Water Line Connection A bypass valve system must be installed to provide for occasions when the water conditioner must is by passed for hard water or for servicing Byp...

Страница 15: ...on the back of the valve control panel Do not drop the transformer or have the cable too taut The transformer is only suitable for internal use only The softener must be weather protected For full un...

Страница 16: ...water pressure is allowed to the control valve and the plumbing system while not allowing water to exit from the control valve to the plumbing Figure 3 4 Shut Off Position The inlet handle points to t...

Страница 17: ...Cleaning the Injector Injector Screen The injector is the component which creates the vacuum necessary to draw the brine into the water conditioner Clean the injector and the injector screen once a ye...

Страница 18: ...ne Connection In the event of a malfunction the tank overflow connection directs overflow to the drain instead of spilling on the floor where it could cause water damage Complete the following steps t...

Страница 19: ...ill Allow to fill the brine compartment Check that water is slowly flowing into the brine well by lifting up the brine well cap 9 Allow to time out and note water level in brine compartment The compar...

Страница 20: ...backwash downflow brining slow rinse second backwash fast rinse refill and downflow service Down flow regeneration 12 volt output AC Adapter provides safe and easy installation Control valve design p...

Страница 21: ...lf lubricating EPDM o rings while the interior surface is sealed against the piston using slippery self cleaning silicone lip seals The lip seals are clear in colour and have a special slippery coatin...

Страница 22: ...xible washer like part with an orifice and a precision moulded contour The flow rates are within 10 over the pressure range of 1 4 bar 20 psi to 8 6 bar 125 psi The drain line flow control and fitting...

Страница 23: ...AS1041TC CL Page 23 SPARE PARTS AND SERVICING INSTRUCTIONS...

Страница 24: ...over Assembly 1 2 V3107 01 WS1 Motor 1 3 V3106 01 WS1 Drive Bracket Spring Clip 1 4 V3108TC WS1 PC Board 1 5 V3110 WS1 Drive Gear 12x36 3 6 V3109 WS1 Drive Gear Cover 1 V3002TC WS1TC Drive ASY Not Sho...

Страница 25: ...g No Order No Description Quantity 1 V3005 WS1Spacer Stack Assembly 1 2 V3004 Drive Cap ASY 1 3 V3178 WS1 Drive Back Plate 1 4 V3011 WS1 Piston Downflow ASY 1 5 V3174 WS1 Regenerant Piston 1 6 V3135 O...

Страница 26: ...OR ASSY BROWN V3010 1C WS1 INJECTOR ASSY VIOLET V3010 1D WS1 INJECTOR ASSY RED V3010 1E WS1 INJECTOR ASSY WHITE V3010 1F WS1 INJECTOR ASSY BLUE V3010 1G WS1 INJECTOR ASSY YELLOW V3010 1H WS1 INJECTOR...

Страница 27: ...tion Quantity 2 H4615 Elbow Locking Clip 1 3 JCP P 6 Polytube insert 3 8 1 4 JCPG 6PBLK Nut 3 8 1 5 H4613 Elbow Cap 3 8 1 6 V3163 O ring 019 1 7 V3165 01 WS1 RFC Retainer ASY 1 8 V3182 WSC RFC 1 Not S...

Страница 28: ...lpm V3162 017 WS1 DLFC 1 7 gpm for 6 5 lpm V3162 022 WS1 DLFC 2 2 gpm for 8 3 lpm V3162 027 WS1 DLFC 2 7 gpm for 10 2 lpm V3162 032 WS1 DLFC 3 2 gpm for 12 1 lpm V3162 042 WS1 DLFC 4 2 gpm for 16 lpm...

Страница 29: ...ting Assembly Order No V3007 01 Description WS1 Fitting 1 PVC Solvent 90 ASY Drawing No Order No Description Quantity 1 V3151 WS1 Nut 1 Quick Connect 2 2 V3150 WS1 Split Ring 2 3 V3105 O Ring 215 2 4...

Страница 30: ...ption Quantity 1 V3151 WS1 Nut 1 Quick Connect 2 2 V3150 WS1 Split Ring 2 3 V3105 O ring 215 2 4 V3145 WS1 Bypass 1 Rotor 2 5 V3146 WS1 Bypass Cap 2 6 V3147 WS1 Bypass Handle 2 7 V3148 WS1 Bypass Roto...

Страница 31: ...AS1041TC CL Page 31 10 V3156 O ring 214 2 Flow Diagrams Service and Backwash flow diagram service...

Страница 32: ...AS1041TC CL Page 32 flow diagram backwash Flow Diagram Down flow Brine...

Страница 33: ...AS1041TC CL Page 33 flow diagram downflow brine Flow Diagrams Rinse and Fill...

Страница 34: ...AS1041TC CL Page 34 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01...

Страница 35: ...CL Page 35 Although no tools are necessary to assemble or disassemble the valve the WS1 wrench shown in various positions on the valve may be purchased to aid in assembly or disassembly Service Instr...

Страница 36: ...pressing on the side of the upper right corner This helps the drive gears mesh with the drive cap assembly The drive bracket is properly seated when it snaps under the latches on the drive back plate...

Страница 37: ...rive cap assembly so it engages the notches moulded into the drive back plate around the top 2 of the piston cavity The notches are visible through the holes Lever the screwdriver so the drive cap ass...

Страница 38: ...bore by hand Since the spacer stack assembly can be compressed it is easier to use a blunt object 15 9mm 5 8 to 28 6 mm 1 1 8 in diameter to push the centre of the assembly into the control valve body...

Страница 39: ...tors make sure the system is depressurized Turn the red arrow shaped handles towards the centre of the bypass valve and back several times to ensure rotor is turning freely The nuts and caps are desig...

Страница 40: ...S1 MICROSWITCH 1 2 V3302 WS1 MOLEX CONNECTOR 1 Not Shown V3303 WS1 MOLEX TERMINAL 3 3 V3304 WS1 SCREWS 4 40 X 5 8 2 4 V3305 WS1 RETAINING RING SS 1 5 V3306 WS1 WASHER ID 0 257 OD 0 640 1 Slip the wash...

Страница 41: ...AS1041TC CL Page 41...

Страница 42: ...AS1041TC CL Page 42 Troubleshooting...

Страница 43: ...the salt storage tank b Days between regenerations too long to accommodate water hardness or water usage c Unit did not regenerate d Plugged injector e Air check valve prematurely closed in brine rise...

Страница 44: ...essure b Defective injector a Increase water pressure b Replace both injector and injector cap Contact dealer 8 Brine tank overflow a Air leak in brine line to air check b Refill control incorrect a C...

Страница 45: ...ary f Drive gear label dirty or damaged missing or broken gear f Replace or clean drive gear g Drive bracket incorrectly aligned to back plate g Reseat drive bracket properly h PC board is damaged or...

Страница 46: ...ing brine solution out of the resin tank to the drain Hardness A common quality of water containing dissolved calcium magnesium and other elements Water hardness is usually expressed milligrams per li...

Отзывы: