AS1041TC-CL
Page
11
Inlet/Outlet Fittings
25mm BSPF PVC elbows
Cycles
6
Valve Material
Noryl (1) or equivalent
Regeneration
Down flow
FLOW RATES
Service @15psi/1 bar drop (includes bypass & meter)
102 lpm
Backwash @25psi/1.7 bar drop (includes bypass)
102 lpm
OPERATING PRESSURE
Minimum/Maximum
330-600 kpa (48-100 psi)
OPERATING TEMPERATURE
5°C---43°C
DIMENSIONS & WEIGHT
Distributor Pilot
1.050” OD Pipe (3/4” NPS)
Drain Line
½” (12mm) Hose Tail
Brine Line
3/8” OD Poly Tube
Mounting Base
2 /12” – 8 NPSM
Height from Top of Tank
7 3/8” (187mm)
Weight
4.5lbs (2kg)
Distributor Pilot
12mm Above Tank Top
ELECTRICAL SPECIFICATIONS
AC Adaptor
Supply Voltage
230V AC
Supply Frequency
50 Hz
Output Voltage
12—16 V AC
Output Current
500 mA
CYCLES OF OPERATION
Factory Set
Minutes
Backwash 1
st
(upflow)
C1
8
Regenerate draw/slow rinse (downflow)
C2
70
Backwash 2
nd
(upflow)
C3
10
Fast Rinse (downflow)
C4
6
*Regenerant Refill (in service with treated water)
C5
17
Service (down flow)
C0
Note C1 to C4 are fixed values and cannot be varied.
C5 will vary to suit model of softener
(Noryl is a trademark of General Electric)
GENERAL” WS1 TC” CONTROL VALVE
SPECIFICATONS
Содержание AST1041TC-CL
Страница 3: ...AS1041TC CL Page 3...
Страница 7: ...AS1041TC CL Page 7 Note Maximum number of days that can be selected is 99...
Страница 23: ...AS1041TC CL Page 23 SPARE PARTS AND SERVICING INSTRUCTIONS...
Страница 31: ...AS1041TC CL Page 31 10 V3156 O ring 214 2 Flow Diagrams Service and Backwash flow diagram service...
Страница 32: ...AS1041TC CL Page 32 flow diagram backwash Flow Diagram Down flow Brine...
Страница 33: ...AS1041TC CL Page 33 flow diagram downflow brine Flow Diagrams Rinse and Fill...
Страница 34: ...AS1041TC CL Page 34 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01...
Страница 41: ...AS1041TC CL Page 41...
Страница 42: ...AS1041TC CL Page 42 Troubleshooting...