Introduction

The  Model  E1  Control  provides  sophisticated, 
demand-based  water  conditioning  by  incorporating  a 
microprocessor  and  a  water  meter  to  electronically 
monitor the amount of water used daily. The control is 
factory  programmed  to  regenerate  when  the  volume 
throughput  setting  is  reached  at  a  present  delayed 
time of 2am. 
 
It  is  recommended  to  de-rate  the  throughput  setting 
by  one  days  general  usage  to  ensure  soft  water  is 
available  on  the  day  of  regeneration.  However  in 
instances where this is not desired the control can be 
reprogrammed so that a regeneration can be initiated 
immediately on reaching the throughput setting. 
 
The control provides efficient, trouble free, soft water. 
 
The  Series WS1-EI valve combines design simplicity 
with  glass  reinforced  NORYL*  plastic  construction  to 
provide an uncommonly reliable appliance. 
 
If  maintenance becomes necessary, the Model WS1-
EI  water  Conditioner  System  has  the  capability  for 
quick repairs. 
 
NORYL is a trademark of GE Plastics. 
 

Special Features 

 

 

Memory  Retention. 

During  a  power  outage, 

critical  operating  information  in  the  control's 
memory  is  stored  in  a  special  electronic  device 
called a NOVARAM. This information includes the 
time 

of 

day, 

water 

usage 

amounts, 

all 

programming  data.  When  power  is  restored,  the 
information  is returned to the microprocessor and 
operation  resumes  as  if  an  outage  never 
occurred.  The  time  of  day  will  be  late  by  the 
length  of  the  power  outage.  Because most power 
outages  are  less  than  one  minute  in  duration,  it 
may  be  months  or  years  before  the  time  display 
requires  resetting.  If  an  outage  of  one  or  more 
hours  occurs, the time of day should be reset but 
no other reprogramming is necessary. 

 

Design Reliability. 

Solid-state electronics assure 

many  years  of  trouble-free  performance.  The 
metering  system  has  only  one  moving  part;  a 
rotating turbine that measures water usage. 

 

Time  and  Capacity  Display. 

During  normal 

conditioning  operation,  the  correct  time  of  day  
and capacity can be accessed on the display. The 
capacity  value  is  the  number  of  cubic  metres  of 
water  that  the  unit  can  condition  before  another 
regeneration is needed. 

 

Flow  indicator. 

The  display  can  access  the 

actual flow rate through the system.

 

 

Throughput  and  Capacity  Setting. 

Once  the 

capacity setting is entered, the information cannot                         

be lost due to a power outage, so reprogramming 
is not necessary.

 

 

Guest  Cycle. 

An  extra  regeneration  can  be 

achieved  at  any  time  by  pressing  the  REGEN 
button  on  the  front  panel.  It  takes  a  few  minutes 
for  the  regeneration  to  start.  The  unit  completes 
the  regeneration  in  about  two  hours.  This  feature 
is  beneficial  when  you  expect  to  use  more  than 
the  normal  amount  of  water;  for  example,  guest 
visits or an extra heavy laundry day.  The manual 
can be set for immediate regeneration of delayed 
regeneration at 2am.

 

 

General Conditioner Information 

 

How Your Conditioner Works 

 

In general, your water conditioner works in the follow-
ing manner. Hard water flows into the conditioner and 
through the resin bed where calcium and magnesium 
hardness  minerals  are  exchange.  The  conditioned 
water  flows  out  of  the  resin  bed  into  your  plumbing 
system.  After  a  certain  amount  of  hard  water  has 
passed  through  the  conditioner,  the  resin  cannot 
remove  any  more  minerals.  This  resin  state  is  called 
exhaustion  and  indicates  that  the  resin  needs  to  be 
regenerated.  The  regeneration  process  restores  the 
conditioner's  ability  to  soften  water.  The  control 
monitors  the  amount  of  water  that  flows  through  the 
conditioner  and  automatically  calculates  when  to 
regenerate the resin bed. 

 

Model E1 Control Front Panel 

 
 
 
 
 
 
 
 
 
 
 

The main components of the model E1 Control front 
panel are: 

 

Main Display Screen with Cycle Time Remaining 

 

Display screen – set as ‘remaining M

3

’ or time of 

day 

 

Display can indicate Rate of Flow 

 

Four-Digit Display 

 

Programming Push Buttons 

Figure 1 

 

 

Содержание AS1041MP-CL

Страница 1: ...PERATING INSTRUCTIONS Model AS1041MP CL Serial No Telephone 07 3219 2233 Facsimile 07 3219 2266 Email sales ibcwater com au Website www ibcwater com au FILTRATION WATER TREATMENT PRODUCTS for commercial industrial and residential application Manufacturer and Supplier of ...

Страница 2: ... Operating Pressure 330 690 kPa Temperature 4 o x 43 o C Electrical 240V 16VAC 50Hz 3 watts maximum Control Valve Series WS1 E1 with bypass valve and installation fittings WARNING A pressure reduction valve must be installed in areas of high water pressure above 690kPa A water hammer arrestor must be installed if water hammer prevails between the softener and the closing off device Caution Do not ...

Страница 3: ...AS1041MP CL Page 3 ...

Страница 4: ...itted in Step 3 taking care not to raise the distributor pipe NEVER shorten the length of the distributor pipe STEP 6 Unpack control valve check that tank O ring is in place Fit the top strainer into the bottom of the valve if not already fitted The strainer has a bayonet style connection end Assemble the control valve to softener tank and screw down hand tight STEP 7 Connect inlet outlet pipes an...

Страница 5: ...hipped unassembled and it is necessary to Assemble the Strainer into the Valve by Matching Up the Locating Lugs and Twisting To Lock prior to the loading of the resin and screwing on the valve to the tank Note Never Shorten the Riser Pipe installed inside the tank ...

Страница 6: ...completed 7 When used as above the tablets change the colour from green to red at a hardness of approximately 20ppm based on a sample volume of 10mls Other hardness test kits are available for more accurate testing eg Hardness Tablets Directions Take a 50ml sample of water in a screw capped bottle Add one 1 tablet to sample shake or crush to disintegrate Repeat until last trace of reddish tinge di...

Страница 7: ...6 5 170 Note The program for M 3 input will only accept the inputting of a whole or half a number e g If the calculated throughput is say 9 75m 3 then what can be programmed in is 9 5 or 10 0 However always select the lower figure i e 9 5 in this example Above 50M the program will only accept increments in 2 5 therefore only input a lower figure eg Calculation gives 58 33 therefore input 57 5 Note...

Страница 8: ...XT to go to Step 3I Step 3I Use or buttons to Set to OFF Press NEXT to go to Step 4I Step 4I Use or buttons to set the time of regen hour Press NEXT to go to Step 5I If the factory default of 2am is to be changed Step 5I Use or buttons to set the time of regen minutes Press NEXT to exit installer display Setting Current Time of Day Push NEXT button until TIME of day screen is displayed ie bar appe...

Страница 9: ...le and will recommence electrically in that cycle when power is restored In long power outages it is advisable to check that the system is not in a regeneration cycle that could be discharging water to drain and in this instance it would be advisable to place the valve in bypass mode until power is restored General Note When changing valve operational cycles the valve control will emit a number of...

Страница 10: ...AS1041MP CL Page 10 MODEL AS1041MP WATER SOFTENER WITH CONTROL VALVE SERIES MODEL WS1EI ...

Страница 11: ...4 NPS Drain Line 3 4 20mm Hose Tail Brine Line 3 8 OD Poly Tube Mounting Base 2 12 8 NPSM Height from Top of Tank 7 3 8 187mm Weight 4 5lbs 2kg Distributor Pilot 12mm Above Tank Top ELECTRICAL SPECIFICATIONS AC Adaptor Supply Voltage 230V AC Supply Frequency 50 Hz Output Voltage 12 16 V AC Output Current 500 mA CYCLES OF OPERATION Range times minutes Factory Set Backwash 1st upflow 1 20 12 Regener...

Страница 12: ... Regeneration 20 Automatic Regeneration Manual Regeneration Care of Your Water Conditioner 20 General Cleaning the Injector Injector Screen Maintaining the Drain Line Brine Line and Brine Tank Overflow Connection 21 Placing Softener into Operation 22 Valve Manual 23 25 Replacement Parts 26 38 Service Instructions 39 46 Troubleshooting 47 49 Alarms Troubleshooting Procedures Glossary of Terms 50 Sa...

Страница 13: ... one moving part a rotating turbine that measures water usage Time and Capacity Display During normal conditioning operation the correct time of day and capacity can be accessed on the display The capacity value is the number of cubic metres of water that the unit can condition before another regeneration is needed Flow indicator The display can access the actual flow rate through the system Throu...

Страница 14: ...wnflow brining and slow rinse downflow fast rinse and refill of the brine tank Optional second backwash available System operation cannot get out of phase or sequence The control always returns to a fixed conditioned water position after regeneration Bypass untreated water is automatically available during regeneration ...

Страница 15: ...bows etc is a reasonable distance to prevent hot water damage A positive way to prevent hot water from flowing from a heat source to the conditioner is to install a check valve in the soft water piping from the conditioner If a check valve is installed make sure that the water heating unit is equipped with a properly rated temperature and pressure safety relief valve Always conform to local codes ...

Страница 16: ...h Do not use a pipe wrench to tighten or loosen nuts or caps Do not place a screwdriver in the slots on caps and or tap with a hammer Do not use pipe dope or other sealant on threads Use teflon tape on threaded inlet outlet and drain fittings Teflon tape is not necessary on the nut connection or caps because of o ring seals After completing any valve maintenance involving the drive assembly of the...

Страница 17: ...dy and rotors are glass filled Noryl or equivalent and the nuts and caps are glass filled polypropylene All seals are self lubricating EPDM to help prevent valve seizing after long periods of non use Internal o rings can easily be replaced if service is required The bypass consists of two interchangeable plug valves that are operated independently by red arrow shaped handles The handles identify t...

Страница 18: ...AS1041MP CL Page 18 ...

Страница 19: ...AS1041MP CL Page 19 WS1EI Screen Display Information And Programming Instructions ...

Страница 20: ...n be used to estimate average daily usage PRESS DOWN ARROW FOR 3 SECONDS TO RESENT TO ZERO User 5 Shows current time Setting Time of Day Push NEXT button until time of day screen is displayed Press and hold the or arrow until the correct hour is displayed Then press NEXT button The minutes will flash Press the or arrow until correct minute is displayed Press the NEXT button to return to the displa...

Страница 21: ...AS1041MP CL Page 21 General Regeneration Error Screens Status ...

Страница 22: ...the Injector Injector Screen The injector is the component which creates the vacuum necessary to draw the brine into the water conditioner Clean the injector and the injector screen once a year in order to maintain proper water conditioning Some locations may require more frequent injector and screen servicing Complete the following steps to clean the injector and the injector screen 1 Unplug the ...

Страница 23: ... Connection In the event of a malfunction the tank overflow connection directs overflow to the drain instead of spilling on the floor where it could cause water damage Complete the following steps to connect the overflow fitting to the brine tank 1 Locate the fitting overflow on the side of the brine tank 2 Attach a length of 1 2in 1 3cm tubing not supplied to the fitting and run to the drain Note...

Страница 24: ... then move down to fill 10 Allow to fill the brine compartment Check that water is slowly flowing into the brine well by lifting up the brine well cap 11 Allow to time out and note water level in brine compartment The compartment should have been prior filled with salt The valve will then go back into the service mode 12 Allow the salt to dissolve in the brine compartment for at least 30 minutes 1...

Страница 25: ...easy access front panel settings Front panel display for time of day volume remaining current flow rate and total volume used Totalizer Four methods to initiate regeneration meter immediate meter delayed time clock delayed or pressure differential Optional double backwash feature offers optimum regeneration cleaning ability and efficiency Fully adjustable 6 cycle control delivers controlled backwa...

Страница 26: ...ires no switches or cams U S Patent 6 444 127 Spacer Stack Assembly The spacer stack assembly provides the necessary flow passage for water during the different cycles The all plastic spacer stack assembly U S Patent 6402944 is a one piece design which allows the stack to be removed using your fingers The exterior of the stack is sealed against the body bore with self lubricating EPDM o rings whil...

Страница 27: ...th a 20mm push on hose elbow Water Meter or Meter Plug The water meter is installed on the outlet side of the control valve The water meter uses a turbine to measure cubic metres of treated water The turbine rotates with the flow of water and reports its rate of rotation through Hall effect 3 circuitry to the printed circuit PC board This rotation permits the PC board to record the total volume of...

Страница 28: ...AS1041MP CL Page 28 SPARE PARTS AND SERVICING INSTRUCTIONS ...

Страница 29: ...er Assembly 1 2 V3107 01 WS1 Motor 1 3 V3106 01 WS1 Drive Bracket Spring Clip 1 4 V3408E1 WS1 5 PC Board EI 1 5 V3110 WS1 Drive Gear 12x36 3 6 V3109 WS1 Drive Gear Cover 1 V3002EI WS1EI Drive ASY Not Shown V3186 01 WS1 AC ADAPTER CORD ONLY 1 Drawing number parts 2 through 6 may be purchased as a complete assembly part V3002EI ...

Страница 30: ...o Description Quantity 1 V3005 WS1Spacer Stack Assembly 1 2 V3004 Drive Cap ASY 1 3 V3178 WS1 Drive Back Plate 1 4 V3011 WS1 Piston Downflow ASY 1 5 V3174 WS1 Regenerant Piston 1 6 V3135 O ring 228 1 7 V3180 O ring 337 1 8 V3105 O ring 215 Distributor Tube 1 Not Shown V3001 WS1 Body ASY Downflow 1 V3011 is labelled with DN ...

Страница 31: ...ASSY BLACK V3010 1B WS1 INJECTOR ASSY BROWN V3010 1C WS1 INJECTOR ASSY VIOLET V3010 1D WS1 INJECTOR ASSY RED V3010 1E WS1 INJECTOR ASSY WHITE V3010 1F WS1 INJECTOR ASSY BLUE V3010 1G WS1 INJECTOR ASSY YELLOW V3010 1H WS1 INJECTOR ASSY GREEN V3010 1I WS1 INJECTOR ASSY ORANGE V3010 1J WS1 INJECTOR ASSY LIGHT BLUE 5 V3010 1K WS1 INJECTOR ASSY LIGHT GREEN 1 Not Shown V3170 O ring 011 Not Shown V3171 O...

Страница 32: ...ly Drawing No Order No Description Quantity 2 H4615 Elbow Locking Clip 1 3 JCP P 6 Polytube insert 3 8 1 4 JCPG 6PBLK Nut 3 8 1 5 H4613 Elbow Cap 3 8 1 6 V3163 O ring 019 1 7 V3165 01 WS1 RFC Retainer ASY 1 8 V3182 WSC RFC 1 Not Shown H4650 Elbow with nut and insert Option Assembly includes V3182 WS1 RFC ...

Страница 33: ...7 gpm for 2 6 lpm V3162 010 WS1 DLFC 1 0 gpm for 3 8 lpm V3162 013 WS1 DLFC 1 3 gpm for 4 9 lpm V3162 017 WS1 DLFC 1 7 gpm for 6 5 lpm V3162 022 WS1 DLFC 2 2 gpm for 8 3 lpm V3162 027 WS1 DLFC 2 7 gpm for 10 2 lpm V3162 032 WS1 DLFC 3 2 gpm for 12 1 lpm V3162 042 WS1 DLFC 4 2 gpm for 16 lpm V3162 053 WS1 DLFC 5 3 gpm for 20 lpm V3162 065 WS1 DLFC 6 5 gpm for 24 7 lpm V3162 075 WS1 DLFC 7 5 gpm for...

Страница 34: ...s standard the illustrated Nut and 5 8 Tube Insert are only supplied as an option Water Meter and meter Plug Drawing No Order No Description Quantity 1 V3151 WS1 Nut 1 QC 1 2 V3003 WS1 Meter ASY 1 3 V3118 01 WS1 Turbine ASY 1 4 V3105 O ring 215 1 Order number V3003 includes V3118 01 WS1 Turbine Assy and V3105 O ring 215 ...

Страница 35: ...tting Assembly Order No V3007 01 Description WS1 Fitting 1 PVC Solvent 90 ASY Drawing No Order No Description Quantity 1 V3151 WS1 Nut 1 Quick Connect 2 2 V3150 WS1 Split Ring 2 3 V3105 O Ring 215 2 4 V3189 WS1 Fitting 1 PVC Solvent 90 2 ...

Страница 36: ...iption Quantity 1 V3151 WS1 Nut 1 Quick Connect 2 2 V3150 WS1 Split Ring 2 3 V3105 O ring 215 2 4 V3145 WS1 Bypass 1 Rotor 2 5 V3146 WS1 Bypass Cap 2 6 V3147 WS1 Bypass Handle 2 7 V3148 WS1 Bypass Rotor Seal Retainer 2 8 V3152 O ring 135 2 9 V3155 O ring 112 2 ...

Страница 37: ...AS1041MP CL Page 37 10 V3156 O ring 214 2 Flow Diagrams Service and Backwash flow diagram service ...

Страница 38: ...AS1041MP CL Page 38 flow diagram backwash Flow Diagram Downflow ...

Страница 39: ...AS1041MP CL Page 39 flow diagram downflow brine Flow Diagrams Rinse and Fill ...

Страница 40: ...AS1041MP CL Page 40 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01 ...

Страница 41: ...P CL Page 41 Although no tools are necessary to assemble or disassemble the valve the WS1 wrench shown in various positions on the valve may be purchased to aid in assembly or disassembly Service Instructions ...

Страница 42: ...ght engaging force on top of the drive bracket while deflecting the bracket slightly to the left by pressing on the side of the upper right corner This helps the drive gears mesh with the drive cap assembly The drive bracket is properly seated when it snaps under the latches on the drive back plate If resistance is felt before latching then notches are not fully engaged the piston rod is not in ho...

Страница 43: ...eals with an o ring To remove the drive cap assembly use the special plastic wrench or insert a to flat blade screwdriver into one of the slots around the top 2 of the drive cap assembly so it engages the notches moulded into the drive back plate around the top 2 of the piston cavity The notches are visible through the holes Lever the screwdriver so the drive cap assembly turns counter clockwise O...

Страница 44: ...cer stack assembly can be pushed in to the control valve body bore by hand Since the spacer stack assembly can be compressed it is easier to use a blunt object 15 9mm 5 8 to 28 6 mm 1 1 8 in diameter to push the centre of the assembly into the control valve body The assembly is properly seated when at least four threads are exposed approximately 15 89 mm 5 8 Do not force the spacer stack assembly ...

Страница 45: ... the PC board Unlatch the drive assembly and lean it forward Unthread the water meter wire from the side of the drive assembly and through the drive back plate To reinstall rethread the water meter wire through the drive back plate and the side of the drive assembly Reattach the drive assembly and the water meter and power plugs If no water meter wire is visible then a plug is installed not a wate...

Страница 46: ...m and the rotor seal Replace worn o rings Clean rotor Reinstall rotor When reinstalling the red arrow handles be sure that 1 The handle pointer are lined up with the control valve body arrows and the rotor seal o ring and retainer on both rotors face to the right when being viewed from the front of the control valve or 2 Arrows point toward each other in the bypass position Since the handles can b...

Страница 47: ...ntity 1 V3301 WS1 MICROSWITCH 1 2 V3302 WS1 MOLEX CONNECTOR 1 Not Shown V3303 WS1 MOLEX TERMINAL 3 3 V3304 WS1 SCREWS 4 40 X 5 8 2 4 V3305 WS1 RETAINING RING SS 1 5 V3306 WS1 WASHER ID 0 257 OD 0 640 1 Slip the washer and retaining ring on to the end of the piston rod Attach the microswitch to the drive bracket using the screws Attach the connector to the microswitch Attach the terminals to wires ...

Страница 48: ...AS1041MP CL Page 48 INJECTOR PERFORMANCE CURVES ...

Страница 49: ...AS1041MP CL Page 49 ...

Страница 50: ...k is completed Problem Cause Solution 1 Hard water at the tap a Low or no salt in the salt storage tank b Capacity setting to low to accommodate water hardness or water usage c Unit did not regenerate d Plugged injector e Air check valve prematurely closed in brine riser pipe a Refill the salt storage tank and manually initiate a regeneration Refer to the Manual Regeneration section in this manual...

Страница 51: ...AS1041MP CL Page 51 ...

Страница 52: ...pressure b Defective injector a Increase water pressure b Replace both injector and injector cap Contact dealer 8 Brine tank overflow a Air leak in brine line to air check b Refill program setting incorrect a Check all connections in brine line for leaks b Contact dealer 9 System using more or less salt than estimated a Inaccurate program setting of brine refill b Air check system incorrect c Defe...

Страница 53: ...ed motor failure e Check motor and wiring Replace motor if necessary f Drive gear label dirty or damaged missing or broken gear f Replace or clean drive gear g Drive bracket incorrectly aligned to back plate g Reseat drive bracket properly h PC board is damaged or defective h Replace PC board 5 Err followed by code number Error Code 1001 Unable to recognize start of regeneration Error Code 1002 Un...

Страница 54: ...drawing the brine solution from the salt storage tank into the resin tank Fast Rinse Purge A flow of water through the resin bed which propels any remaining brine solution out of the resin tank to the drain Hardness A common quality of water containing dissolved calcium magnesium and other elements Water hardness is usually expressed milligrams per litre as calcium carbonate equivalent Manual Rege...

Отзывы: