The WS1-E1 has been factory programmed with the majority of the commands and parameters installed. It is
necessary on commissioning of the softener to program in the
M
3
throughput
” and if desired another
time of
day
when regeneration is to proceed or accept the
factory default of 2am
and to set up the clock to register
the current time of day. The transformer plugs into the adaptor mounted on the back face of the front panel of
the valve
The procedure is as follows :
Plug in the transformer into the mains and turn on – valve will sequence to the service position
.
CUSTOMER/ INSTALLER
PROGRAMING INSTRUCTIONS
Step 1I
– To enter installer display press the
NEXT
and
▲
buttons simultaneously for 5 seconds and
release. Display flashes.
Step 2I
– Using the
keys
input desired
volumetric
throughput
capacity (table 2 ) in cubic
meters ( Adjustable from 0.5 - 250.0). It is suggested
the value entered be equal to the actual volumetric
capacity minus a 1 day’s estimated water usage.
Press
NEXT
to go to Step 3I
Step 3I
– Use or buttons to Set to “OFF” .
Press
NEXT
to go to Step 4I.
Step 4I
– Use or buttons to set the time of regen
‘hour’
. Press
NEXT
to go to Step 5I. If the factory
default of 2am is to be changed.
Step 5I
– Use or buttons to set the time of regen
‘minutes’
. Press
NEXT
to
exit
installer display.
Setting Current Time of Day
Push
NEXT
button until
TIME
of day screen is
displayed ie bar appears under TIME function . Press
and hold the OR arrow until a arrow appears
against SET and
release
the button and the hour
display flashes and then set the correct hour. Then
press the
NEXT
button. The minutes will flash. Press
the
OR
arrow until the correct minutes is
displayed. Note only press
one
▲
OR
▼
button NOT
both together.
Press the NEXT button to return to the display screens.
If the NEXT button is not pressed hours or minutes will
flash for five minutes before returning to display
screen.
Then using the
NEXT
button select which screen you
wished displayed. Recommended to leave on
‘
remaining-M
3
’
.
Exit back to display screen which would normally show
‘remaining M
3
’. Note: When in the program mode. Step 1 to
5. If it is desired to go back one program step press ‘regen’
button to return back.
Содержание AS1041MP-CL
Страница 3: ...AS1041MP CL Page 3 ...
Страница 10: ...AS1041MP CL Page 10 MODEL AS1041MP WATER SOFTENER WITH CONTROL VALVE SERIES MODEL WS1EI ...
Страница 18: ...AS1041MP CL Page 18 ...
Страница 19: ...AS1041MP CL Page 19 WS1EI Screen Display Information And Programming Instructions ...
Страница 21: ...AS1041MP CL Page 21 General Regeneration Error Screens Status ...
Страница 28: ...AS1041MP CL Page 28 SPARE PARTS AND SERVICING INSTRUCTIONS ...
Страница 37: ...AS1041MP CL Page 37 10 V3156 O ring 214 2 Flow Diagrams Service and Backwash flow diagram service ...
Страница 38: ...AS1041MP CL Page 38 flow diagram backwash Flow Diagram Downflow ...
Страница 39: ...AS1041MP CL Page 39 flow diagram downflow brine Flow Diagrams Rinse and Fill ...
Страница 40: ...AS1041MP CL Page 40 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01 ...
Страница 48: ...AS1041MP CL Page 48 INJECTOR PERFORMANCE CURVES ...
Страница 49: ...AS1041MP CL Page 49 ...
Страница 51: ...AS1041MP CL Page 51 ...