Table 3 – Troubleshooting Procedures - cont…
6. Control does not draw
brine.
a. Low water pressure
b. Restricted drain line.
c. Injector or injector screen plugged.
!
d. Injector defective.
!
e. Valve general malfunction
f. Air check prematurely closed in
brine tank
a. Increase water pressure.
b. Remove restriction.
c. Clean injector and screen, Refer to the
Cleaning the Injector/Injector Screen
section in this manual.
d. Replace injector. Contact dealer.
e. Contact dealer
f. Replace or repair air check if needed.
Check brine line connections.
7. Intermittent or irregular
brine draw.
a. Low water pressure.
b. Defective injector.
!
a. Increase water pressure.
b. Replace both injector and injector cap.
Contact dealer.
8. Brine tank overflow.
a. Air leak in brine line to air check.
b. Refill program setting incorrect.
a. Check all connections in brine line for
leaks.
b. Contact dealer.
9. System using more or
less salt than estimated.
a. Inaccurate program setting of brine
refill.
b. Air check system incorrect.
c. Defective brine refill operation
control
a. Contact dealer.
b. Contact dealer.
c. Contact dealer.
10. Control backwashes at
excessively low or high
rate.
a. Incorrect backwash controller.
b. Foreign matter affecting controller
operation. !
a. Contact dealer.
b. Remove backwash controller. Clean &
replace.
11. Flowing or dripping water
at drain line after
regeneration.
a. Internal valve malfunction.
a. Contact dealer.
Содержание AS1041MP-CL
Страница 3: ...AS1041MP CL Page 3 ...
Страница 10: ...AS1041MP CL Page 10 MODEL AS1041MP WATER SOFTENER WITH CONTROL VALVE SERIES MODEL WS1EI ...
Страница 18: ...AS1041MP CL Page 18 ...
Страница 19: ...AS1041MP CL Page 19 WS1EI Screen Display Information And Programming Instructions ...
Страница 21: ...AS1041MP CL Page 21 General Regeneration Error Screens Status ...
Страница 28: ...AS1041MP CL Page 28 SPARE PARTS AND SERVICING INSTRUCTIONS ...
Страница 37: ...AS1041MP CL Page 37 10 V3156 O ring 214 2 Flow Diagrams Service and Backwash flow diagram service ...
Страница 38: ...AS1041MP CL Page 38 flow diagram backwash Flow Diagram Downflow ...
Страница 39: ...AS1041MP CL Page 39 flow diagram downflow brine Flow Diagrams Rinse and Fill ...
Страница 40: ...AS1041MP CL Page 40 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01 ...
Страница 48: ...AS1041MP CL Page 48 INJECTOR PERFORMANCE CURVES ...
Страница 49: ...AS1041MP CL Page 49 ...
Страница 51: ...AS1041MP CL Page 51 ...