Microprocessor Troubleshooting Procedures
Problem
Possible Cause
Solution
a. AC Adapter unplugged
a. Connect power
b. No electric power at outlet
b. Repair outlet or use working outlet
c. Defective AC adapter
c. Replace AC adapter
1. Timer does not display time
of day.
d. Defective PC board
d. Replace PC board
a. Switched outlet
a. Use uninterrupted outlet
b. Power Outage
b. Reset time of day
2. Timer does not display correct
time of day.
c. Defective PC board
c. Replace PC board
a. Bypass valve in bypass position
a. Put bypass valve in service position
b. Meter connection disconnected
b. Connect meter to PC board
c. Restricted/stalled meter turbine
c. Remove meter and check for rotation
or foreign material
d. Defective meter
d. Replace meter
3. No softening/filtering display
when water is flowing.
e. Defective PC board
e. Replace PC board
a. power outages
a. Reset control valve to correct time of
day
b. Time of day not set correctly
b. Reset to correct time of day
c. Time of regeneration incorrect
c. Reset regeneration time
4. Control valve regenerates
at wrong time of day.
d. Control valve set at “on O”
(immediate regeneration)
d. Check control valve set-up procedure
regeneration time option.
a. Control valve has just been serviced
a. Press NEXT and REGEN for 3 seconds
or unplug power source jack (black wire)
and plug back in to reset control valve.
b. Foreign matter is lodged in control
valve
b. Check piston and spacer stack assembly
for foreign matter
c. high drive forces on piston
c. Replace piston(s) & spacer stack
assembly
d. Control valve piston not in home
position
c. Press NEXT and RGEN for 3 seconds
or unplug power source jack (black wire)
and plug back in to reset control valve
e. Motor not inserted fully to engage
pinion, motor wires broken or
disconnected, motor failure
e. Check motor and wiring. Replace motor if
necessary
f. Drive gear label dirty or damaged,
missing or broken gear
f. Replace or clean drive gear
g. Drive bracket incorrectly aligned to
back plate
g. Reseat drive bracket properly
h. PC board is damaged or defective
h. Replace PC board
5. Err followed by code number
Error Code 1001 – Unable to recognize
start of regeneration
Error Code 1002-Unexpected stall
Error Code 1003-Motor ran too long,
timed out trying to reach next cycle
position
Error 1004 – Motor ran too long, timed
out trying to reach home position
If other Error Codes display contact the
factory.
i. PC board incorrectly aligned to drive
bracket.
i. Ensure PC board is correctly snapped on
to drive bracket.
a. Motor not operating
a. Replace motor
b. No electric power at outlet
b. Repair outlet or use working outlet
c. Broken drive gear or drive cap
assembly
c. Replace AC adapter
d. Defective PC board
d. Replace PC board
e. Broken drive gear or drive cap
assembly
e. Replace drive gear or drive cap assembly
f. Broken piston retainer
f. Replace piston retainer
6. Control valve stalled in
regeneration
g. Broken main or regenerant piston
g. Replace main or regenerant piston
a. AC adapter unplugged
a. Connect AC adapter
b. No electric power at outlet
b. Repair outlet or use working outlet
c. Broken drive gear or drive cap
assembly
c. Replace drive gear or drive cap assembly
7. Control valve does not regenerate
automatically when REGEN button
is depressed and held
d. Defective PC board
d. Replace PC board
a. Bypass valve in bypass position
a. Put bypass valve in normal operation
position.
b. Meter connection disconnected
b. Connect meter to PC board
c. Restricted/stalled meter turbine
c. Remove meter and check for rotation or
foreign matter
d. Defective meter
d. Replace meter
e. Defective PC board
e. Replace PC board
8. Control valve does not
Regenerate automatically but
does when REGEN button is
depressed
f. Set-up error
f. Check control valve set-up procedure
Содержание AS1029MP-CL
Страница 3: ...AS1029MP CL Page 3...
Страница 5: ...AS1029MP CL Page 5...
Страница 11: ...AS1029MP CL Page 11 MODEL AS1029MP WATER SOFTENER WITH CONTROL VALVE SERIES MODEL WS1EI...
Страница 19: ...AS1029MP CL Page 19...
Страница 20: ...AS1029MP CL Page 20 WS1EI Screen Display Information And Programming Instructions...
Страница 22: ...AS1029MP CL Page 22 General Regeneration Error Screens Status...
Страница 29: ...AS1029MP CL Page 29 SPARE PARTS AND SERVICING INSTRUCTIONS...
Страница 38: ...AS1029MP CL Page 38 10 V3156 O ring 214 2 Flow Diagrams Service and Backwash flow diagram service...
Страница 39: ...AS1029MP CL Page 39 flow diagram backwash Flow Diagram Downflow...
Страница 40: ...AS1029MP CL Page 40 flow diagram downflow brine Flow Diagrams Rinse and Fill...
Страница 41: ...AS1029MP CL Page 41 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01...
Страница 49: ...AS1029MP CL Page 49 INJECTOR PERFORMANCE CURVES...
Страница 50: ...AS1029MP CL Page 50...
Страница 52: ...AS1029MP CL Page 52...