Installation
All plumbing and electrical connections must conform
to local codes. Inspect the unit carefully for carrier
shortage or shipping damage.
Location Selection
•
Locate unit as close to a drain as possible
•
If supplementary water treating equipment is
required, make sure that adequate additional
space is available. Locate the cabinet softener in
an accessible place so that salt can easily be
added.
•
Do not install any unit closer than 3m (10ft) of
piping between the outlet of the water conditioner
and the inlet of the water heater. Water heaters
can transmit heat back down the cold water pipe
into the control valve. Hot water can severely
damage the controller.
A 3m total pipe run (including bends, elbows etc) is a
reasonable distance to prevent hot water damage. A
positive way to prevent hot water from flowing from a
heat source to the conditioner is to install a check
valve in the soft water piping from the conditioner. If a
check valve is installed, make sure that the water-
heating unit is equipped with a properly rated
temperature and pressure safety relief valve. Always
conform to local codes.
•
Do not locate the unit in an area where the temp
ever falls below 1ºC (34ºF) or over 49ºC (120ºF).
•
Do not install the unit near acid or acid fumes.
•
Do not expose the unit to petroleum products.
Water Line Connection
A bypass valve system must be installed to provide
for occasions when the water conditioner must is by-
passed for hard water or for servicing. Bypass offers
simplicity and ease of operation. These softeners are
equipped as standard with a bypass valve. See pages
14 and15
Drain Line Connection – to sewer
Figure 3 – Typical Illustration of a Bypass
Содержание AS1029MP-CL
Страница 3: ...AS1029MP CL Page 3...
Страница 5: ...AS1029MP CL Page 5...
Страница 11: ...AS1029MP CL Page 11 MODEL AS1029MP WATER SOFTENER WITH CONTROL VALVE SERIES MODEL WS1EI...
Страница 19: ...AS1029MP CL Page 19...
Страница 20: ...AS1029MP CL Page 20 WS1EI Screen Display Information And Programming Instructions...
Страница 22: ...AS1029MP CL Page 22 General Regeneration Error Screens Status...
Страница 29: ...AS1029MP CL Page 29 SPARE PARTS AND SERVICING INSTRUCTIONS...
Страница 38: ...AS1029MP CL Page 38 10 V3156 O ring 214 2 Flow Diagrams Service and Backwash flow diagram service...
Страница 39: ...AS1029MP CL Page 39 flow diagram backwash Flow Diagram Downflow...
Страница 40: ...AS1029MP CL Page 40 flow diagram downflow brine Flow Diagrams Rinse and Fill...
Страница 41: ...AS1029MP CL Page 41 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01...
Страница 49: ...AS1029MP CL Page 49 INJECTOR PERFORMANCE CURVES...
Страница 50: ...AS1029MP CL Page 50...
Страница 52: ...AS1029MP CL Page 52...