Manual
Issue 1.3
65
“Analog” tab
Figure 38: Basic submodule
– “Analog” tab
The Basic submodule captures the following characteristic values:
Power frequency in 200 ms and half period measurement intervals, respectively
For each input: RMS value, peak value, rectified value and frequency in 200 ms
and half period measurement intervals
For each input: Phase angle, form factor, crest factor, measurement interval
200 ms.
In the signal display, the signals are grouped by input. Click the <+> sign before the group
name to show the signals of a group.
Name
The names are set by default but can be edited. To allow an unambiguous identifi-
cation, they contain the input channel and the characteristic value. You can addi-
tionally assign two comments by clicking the
icon in the signal name field.
Unit
Display of the relevant unit.
Active
Here you can enable or disable the signal.