7
Device description
7.1
Properties
24 V DC unregulated external power supply required (18…32 V input voltage pos-
sible)
DIN rail mountable, EMI protected, robust metal housing
3 LED device status indicators (Run, Link, Error)
TX/RX fiber-optic ports for transmission of measured data and reception of configu-
ration requests as well as multiplexing of up to 96 devices
Programmable sampling rate (period) between 40 µs (25 kHz) and 2 ms (500 Hz) in
steps of 50 nanoseconds
8 analog inputs with +/- 10 V, 14-bit ADC, galvanic isolation
8 binary inputs with galvanic isolation and 8 status outputs via LED
Maximum device communication speed of 200 k samples per second
RJ11 socket (ibaCom-PCMCIA interface card is not yet supported)
Service interface
Shield terminal for proper grounding of the device to eliminate ground loops