11.3.3.1  Channel properties (mode independent) 

 

  TTLThreshold:   

Only for 

„SE“, detection between log. „0“ and log. „1“. 

  0: 

1 V 

  1: 

1.2 V  - default for TTL (5 V) 

  2: 

2.4 V 

  3: 

5 V 

- default for HTL (24 V) 

  Enable5VOut:   

Internal encoder supply 5 V DC connected to external  V

cc

  

  EnablePullUpInt: 

 

Only for 

„SE“ and open collector connection, internal supply (V

cc

 = 5 V) 1 kOhm 

pullup (only A, B, N) connected 

  EnablePullUpExt: 

 

Only for 

„SE“ and open collector connection, external supply (V

cc

 = 24 V) 1 kOhm 

pullup (only A, B, N) connected 

  EnablePullDown: 

 

1 kOhm pulldown resistor connected (only A, B, N)

; however, usually always “false” 

  AsyncMode: 

 

Does not have any function; however, always needs to be 

„false“ and has to be 

commented in 

  NoSafeOutput:  

Does not have any function; however, always needs to be 

„false“ and has to be 

commented in 

 

 

 

 

Содержание ibaMS4xUCO

Страница 1: ...ibaMS4xUCO I O module with 4 counter inputs and digital inputs and outputs Manual Issue 1 5...

Страница 2: ...of the Microsoft Corporation Other prod uct and company names mentioned in this manual can be labels or registered trade marks of the corresponding owners Certification The product is certified accor...

Страница 3: ...6 3 Dismounting 13 7 Device description 14 7 1 Views 14 7 2 Indicating elements 14 7 2 1 Operating status L1 L4 14 7 2 2 Counter inputs digital outputs L30 L45 15 7 2 3 Digital inputs L10 L17 15 7 3 C...

Страница 4: ...39 9 2 3 Configurations of outputs 45 9 3 Configuration in ibaLogic V5 48 9 3 1 Rotary encoder configuration 48 9 3 2 Configuring signals 49 10 Technical Data 52 10 1 Main data 52 10 2 Counter inputs...

Страница 5: ...ibaMS4xUCO Manual Issue 1 5 5 12 Support and contact 82...

Страница 6: ...in delivery The documentation of the iba modular system comprises the following manuals Central units The manuals of the central units e g ibaPADU S IT 2x16 and ibaPADU S CM contain the following inf...

Страница 7: ...ible consequences and risks on the basis of his her specialist training knowledge and experience and knowledge of the standard regulations 1 2 Notations In this manual the following notations are used...

Страница 8: ...s and the system or machine to be controlled there is a risk of death or severe injury The non observance of this safety information may result in a potential risk of death or severe injury The non ob...

Страница 9: ...he iba modular system Counter module with 4 inputs Galvanically isolated single ended 50 MHz 20 ns 32 bit resolution Max input signal level TTL 5 V Transistor Transistor Logic HTL 24 V High Threshold...

Страница 10: ...ry please check it for completeness and have a look if the parts might be damaged The scope of delivery comprises ibaMS4xUCO device 1 x 37 pole Sub D connector 1 x 16 pin multi pin connector 1 x 6 pin...

Страница 11: ...al safety instructions Strictly observe the operating voltage range see Technical Data Never use damaged measuring cables Measuring cables must NOT be attached or detached to from the device under vol...

Страница 12: ...DU S CM version 02 12 004 or later Back plane unit e g ibaPADU B4S 5 2 Software ibaPDA version 6 38 0 or later ibaLogic V5 version 5 0 5 or later Note The use of ibaLogic V5 requires the central unit...

Страница 13: ...ckplane 4 Secure the device with the fixing screws Important note Always screw tight the device and the modules If you do not screw it tight connecting or disconnecting the connectors for the inputs a...

Страница 14: ...onnector for digital inputs X5 Sub D connector counter inputs X28 Figure 1 Front view 7 2 Indicating elements The operating status of the device and the status of the channels are shown by colored sta...

Страница 15: ...ut Status Counter inputs Status Digital outputs Off Green Yellow Red no signal logical 0 rotary encoder mode 0 deactivated signal ok logical 1 signal not used channel failure Off Green Yellow no signa...

Страница 16: ...Manual ibaMS4xUCO 16 Issue 1 5 7 3 Connection diagram The module provides 3 channel groups Digital outputs top left Counter inputs on the bottom left Digital inputs right Figure 2 Connection diagram...

Страница 17: ...and the mode Signal Description A Main signal 1 A Differential signal to A B Main signal 2 can also be enable signal for A B Differential signal to B N Reset signal for counter N Differential signal...

Страница 18: ...l voltage Enable 1k Pullup on internal 5 V 5 V VCH A B N A B N GND TTL Threshold Voltage 0 1 2 3 1 V 1 2 V 2 4 V 5 V 1 1 TTLMode 0 DiffMode 0 Invert Polarity 0 1 Current limiting 10mA KANAL KANAL KANA...

Страница 19: ...her with 1 k pulldown for TTL mode Enable analog filter on TTL input A B N MF Enables the 180 kHz RC low pass filter only when TTL mode is active 1 TTLMode 0 DiffMode A B N Switch between differential...

Страница 20: ...de There are basically two counting modes Direct mode Quadrature mode Direct mode In direct mode only the edges of the A signal are counted The following options are possible the rising edge the falli...

Страница 21: ...t Counter t 1 2 3 4 5 RisingEdge A FallingEdge A BothEdges A Figure 7 B as qualifier Only when B logical 1 the relevant edges will be counted 7 4 4 3 Pulse counter The way of counting the edges depen...

Страница 22: ...quadrature mode the counter is incremented by 4 all 4 edges are counted For this case the divide by 4 function can be activated in order to divide the counter reading by 4 7 4 4 5 Period frequency cal...

Страница 23: ...first rising edge and ends when a rising edge happens after the minimum measuring time has elapsed Since several periods may be passed during the measuring time the frequency is averaged over the mea...

Страница 24: ...by using a virtual module see chapter 11 4 1 7 4 4 6 Pulse width duty cycle When measuring the pulse width the 50 MHz clock cycles of the internal quartz oscillator are counted as for the period time...

Страница 25: ...nals A B N are interpreted and processed in different ways Hence different analog input values are available for the system Depending on the mode one or three different values are available see the fo...

Страница 26: ...utyCycle DINT DINT REAL Refers solely to signal A PeriodTime is the period duration in ns PulseWidth is the positive pulse width of A DutyCycle is the duty factor between high and low level DutyCycle...

Страница 27: ...function The output channels provide a self protection function in order to avoid damages to the device under fault conditions in the load circuit as far as possible Each load current of all 4 channe...

Страница 28: ...t even if the connection is polarity reversed 7 6 1 Pin assignment Figure 14 Connection diagram digital inputs X5 X5 Pin Connection LED 1 Digital input 00 L10 2 Digital input 00 3 Digital input 01 L11...

Страница 29: ...between 1 s 65535 s Off The measured input signal is transferred without filtering Stretch rising edge With the first rising edge the input signal red switches to logical 1 and keeps this value for t...

Страница 30: ...or the next edge be it rising or falling Figure 17 Debounce filter Stretch both edges Delay both edges Beginning with the first edge the output signal purple blocks the input and keeps the logical val...

Страница 31: ...e version of the central unit the central unit does an automatic up or downgrade of the module Thereafter the module is ready to be used Important note The overall release version contains all modules...

Страница 32: ...ba modular system in your browser and select the central unit On the update tab click on the Browse button and choose the padusit2x16_ v xx yy zzz iba update file By clicking on Start Update you start...

Страница 33: ...ver sion FPGA version and serial number is displayed in the Diagnostics tab Open the ibaPDA I O manager and choose your iba modular system in the tree structure see also the figure above 8 4 2 Web int...

Страница 34: ...formation and technical specifications of the I O module Figure 21 info tab 8 4 2 2 notes tab On the notes tab you can enter notes e g for notes on wiring or on recording of changes By clicking on sav...

Страница 35: ...ile can be manually created For this purpose a template may be used which is available on the DVD iba Software Manuals 02_iba_Hardware ibaMS4xUCO EncoderParameterFiles XML Template The de scription of...

Страница 36: ...lso configure further settings in the following configuration steps Help Explanations and notes regarding the configuration settings are displayed automatically in this area Depending on the cursor po...

Страница 37: ...he ecnoder type and is preselected Figure 26 Encoder parameter file in the drop down list In addition an external storage location can be specified e g for later use with ibaLogic Figure 27 Save encod...

Страница 38: ...tions are described in the help window or explained in the manual see chapter 7 4 With Open you can open an existing configuration file using the Save button you can save a new or modified encoder par...

Страница 39: ...ion of the module Note The automatic detection requires a bidirectional FO connection from the ibaPDA com puter to the central unit Other documentation If you want to install the ibaPADU S system at f...

Страница 40: ...gnal acquisition Name The plain text name should be entered here as the module designation Module No Internal reference number of the module This number determines the order of the modules in the sign...

Страница 41: ...upports this function Import signal names True The modules and signals configured by the embedded application cannot be con figured in ibaPDA they are displayed in gray in the respective fields The co...

Страница 42: ...n select all analog signals provided by the module Note Number and type of the analog signals depend on the selected encoder mode see General tab ibaPDA scales the calculated analog value to the targe...

Страница 43: ...vert a standardized value transferred without a unit into a physical value You can choose by Gain Offset a conversion of the value The value is then rec orded with the physical unit For making the cal...

Страница 44: ...l comments click on the icon in the Name field Debounce filter In the dropdown menu you can choose the operating mode for the debounce filter You have got the following settings at your disposal Off s...

Страница 45: ...rtual signals can be defined with the expression builder in ibaPDA Other documentation For a detailed description of the expression editor see ibaPDA manual chapter Expres sion editor 9 2 3 1 Outputs...

Страница 46: ...ed to the outputs or signals can be linked mathematically or logically Active Enabling disabling the signal 9 2 3 3 Outputs menu Reset channel errors tab There are two ways to reset hardware errors of...

Страница 47: ...ibaMS4xUCO Manual Issue 1 5 47 Expression By means of the expression editor you can configure an output signal to reset a hardware error Active Enabling disabling the signal...

Страница 48: ...c Open the I O Config urator in the Tools I O Configurator menu When you click on the Update hardware button then ibaLogic detects the module 9 3 1 Rotary encoder configuration The rotary encoder type...

Страница 49: ...manently available and can be freely configured Note The number type and name of the ibaMS4xUCO counter input signals depend on the selected mode see chapter 9 3 1 The output signals of the digital in...

Страница 50: ...UCO_AI_Ch0 00 03 _ sig nal_name_depending_on_mode vary depending on the mode Figure 37 ibaMS4xUCO inputs If Buffered Access is enabled you can see additional input and output signals Note You need to...

Страница 51: ...output signals DebType_Ch 00 07 Debounce filter for digital input signals DebTime_Ch 00 07 Debounce time for the single digital input signal MinPeriods_Ch 00 03 Minimum number of periods to be measure...

Страница 52: ...lation Counter inputs digital outputs Counter inputs digital inputs Digital outputs digital inputs AC 1 5 kV AC 2 5 kV AC 2 5 kV Operating and environmental conditions Cooling Passive Operating temper...

Страница 53: ...er 180 kHz in addition 0 Hz 500 kHz SE or 0 Hz 2 MHz DIF Absolute encoder connection Functions SSI interface SSI master receiver SSI slave receiver Max clock frequency Tf Data rate SSI master receiver...

Страница 54: ...to 20 kHz Delay Typ 10 s Electrical isolation Channel channel Channel housing power supply AC 2 5 kV AC 2 5 kV Connector type 1 x 16 pin multi pin connector clamp type terminal 0 8 mm2 to 2 5 mm2 scre...

Страница 55: ...nector clamp type terminal 0 8 mm2 to 2 5 mm2 screw connection included in deliv ery Protective functions Safe state Channel root switched off Current limitation From approx 0 6 A per channel The root...

Страница 56: ...Manual ibaMS4xUCO 56 Issue 1 5 Dimensions in mm Figure 39 Module dimensions with connectors...

Страница 57: ...Signal paths which are not active are not illustrated described The circuit dia gram in chapter 7 4 3 gives an overview This chapter describes only active signal paths Further supported encoder types...

Страница 58: ...alarm output is typically open when an alarm is active The Sony MD50 rotary encoder is to be connected to ibaMS4xUCO as indicated below 120 A A RS485 120 B B RS485 270 1 k 5 V MF GND 2 4 V COMP VDigOu...

Страница 59: ...easured frequency is four times as high as the real frequency the period time decreases accordingly by factor 4 PeriodTime is the period duration in ns ABDirection ABDirection 0 A pulse before B pulse...

Страница 60: ...ted parameters Analysis regulation 1 Pulse counter 2 Period fre quency 3 Pulse width duty cycle 4 Up down counter Mode Q Q Direct Quadrature Signal edge pos A 6 High level neg A pos B neg B Function D...

Страница 61: ...Pin assignment H bner FG4 FGH4 11 1 2 2 Circuit diagram The H bner FG4 rotary encoder is to be connected to ibaMS4xUCO as indicated below 120 A A RS485 120 B B RS485 MF GND H bner FG4 VCC unused n nG...

Страница 62: ...ured frequency is four times as high as the real frequency the period time decreases accordingly by factor 4 PeriodTime is the period duration in ns ABDirection ABDirection 0 A pulse before B pulse AB...

Страница 63: ...al edge pos A 7 High level neg A pos B neg B Function Divide by 4 Reset on N B as qualifier 11 1 3 Hengstler RI58 O xAx xxRx 11 1 3 1 Pin assignment GND N MF N B A B A VCC GND B A ALARM N A B N 1 k Fi...

Страница 64: ...nnection to ibaMS4xUCO 11 1 3 3 Modes Analysis regulations The following modes and analysis regulations are realized for the Hengstler RI58 O xAx xxRx rotary encoder Mode Calculated input values Descr...

Страница 65: ...AL Refers solely to signal A PeriodTime is the period duration in ns PulseWidth is the positive pulse width of A DutyCycle is the duty factor between high und low level DutyCycle 0 1 4 Up down counter...

Страница 66: ...11 2 1 1 Single ended SE TTL Usually the output circuit of the rotary encoder is designed as push pull amplifier In this case the ibaMS4xUCO module is connected as follows In case the output circuit i...

Страница 67: ...tput circuit of the rotary encoder is designed as push pull amplifier In this case the ibaMS4xUCO module is connected as follows In case the output circuit is an open collector the ibaMS4xUCO module h...

Страница 68: ...counter inputs of the ibaMS4xUCO module are designed for TTL the appropriate series resistors have to be inserted into the signal circuits here for Vmax 30 V In case you don t need termination e g yo...

Страница 69: ...ncoder SSI An absolute encoder SSI is only intended as differential DIF and as TTL 11 2 2 1 SSI master receiver 11 2 2 2 SSI slave receiver The slave receiver function is usually used to be able to li...

Страница 70: ...Manual ibaMS4xUCO 70 Issue 1 5 Therefore connected terminating resistors can lead to an incomplete line termination For this reason no terminating resistors are connected in this connection example...

Страница 71: ...e the encoder specific parameters which are based on the manufacturer specific data sheet are entered The encoder parameter file is created as XML file and contains the following three sec tions The o...

Страница 72: ...ters numbers and minus no spaces allowed Note The file name of the encoder parameter file derives from DeviceName and VendorName file extension xml The two character strings under Value have to be ado...

Страница 73: ...at is connected but disabled This entry should not be changed and also not be commented out 11 3 2 2 Mode 1 Pulse counter Mode The number of the respective mode ResetOnN True resets the counter if the...

Страница 74: ...ty cycle calculation Mode The number of the respective mode 11 3 2 5 Mode 4 Upcounter Downcounter Mode The number of the respective counter ResetOnN True resets the counter if there is a high level on...

Страница 75: ...ption GrayDecode False Decoding according to SSI Binary True Decoding according to SSI Gray 11 3 2 7 Mode 6 SSI Master receiver Mode The number of the respective mode SSIClockNumber Bit width resoluti...

Страница 76: ...Manual ibaMS4xUCO 76 Issue 1 5 11 3 3 Section 3 IO configuration For an overview of the wiring please also see chap 7 4 3 SE single ended DIF differential...

Страница 77: ...SE and open collector connection internal supply Vcc 5 V 1 kOhm pullup only A B N connected EnablePullUpExt Only for SE and open collector connection external supply Vcc 24 V 1 kOhm pullup only A B N...

Страница 78: ...Inverts signal polarity EnableAnalogFilter_A Only for SE enables analog RC low pass filter with 180 kHz FilterMode_A Enables debounce filter 0 Off without filter 1 Stretch rising edge 2 Stretch falli...

Страница 79: ...Vcc 5 V 250 Ohm pullup connected InvertPolarity_MF Inverts signal polarity EnableAnalogFilter_MF Enables the analog RC low pass filter with 180 kHz FilterMode_MF Enables debounce filter 0 Off without...

Страница 80: ...ules refer to the ibaPDA manual This is the expression for calculating the speed in a virtual module Revolutions second measured frequency pulses per revolution or Revolutions minute measured frequenc...

Страница 81: ...ircumference of the measuring wheel pulses per revolution Note The resolution pulses per revolution of the rotary encoder is important for distance measurement This has to be determined in advance The...

Страница 82: ...rial number iba S N of the product Contact Headquarters iba AG Postbox 1828 DE 90708 F rth Germany Phone 49 911 97282 0 Fax 49 911 97282 33 E mail iba iba ag com Contact Harald Opel Shipping address i...

Отзывы: