9.2.2.1 Hardware menu -
„General“ tab
Figure 29: I/O manager ibaMS4xUCO
– General tab
Basic
Module Type
(information only)
Indicates the type of the current module.
Locked
A module can be locked to avoid unintentional or unauthorized changing of the
module settings.
Enabled
Disabled modules are excluded from signal acquisition.
Name
The plain text name should be entered here as the module designation.
Module No.
Internal reference number of the module. This number determines the order of the
modules in the signal tree of ibaPDA client and ibaAnalyzer.
Timebase
Timebase, specified in the PADU-S module.
Use name as prefix
Puts the module name in front of the signal names.
Configuration set by
This item is only visible when ibaPADU-S-IT-2x16 is used as central unit. When an
embedded application has been started on ibaPADU-S-IT-2x16 (e. g. ibaLogic),