I&J4000-LF Series Operating Manual
Section 5: Point Type & Function Reference
Part # 562187
Rev. E - Jan. 08
- Page 39 -
© 2008 I&J Fisnar Inc.
1.3 Line
Passing
Registers the current XYZ location as a Line Passing point. This is a location on the line
where the tip changes direction, such as at the corner on a rectangle.
Also use a Line passing point before and after an Arc Point instruction.
1.4 Circle
Registers a circle, where the circle’s center is at the current XYZ location. To register a
circle, jog the tip to the circle’s center and press
ENTER
, and then press the key 4 (for
circle). The display will prompt you to type the following data:
Diameter : Type the diameter of the circle and press
ENTER.
Over Angle: (The value is from 1~360). After dispensing the circle, while going through an
extra part of the circle defined by the Over Angle, the dispenser will be turned OFF.
Z Left: 1. Yes 2. No
Selection : If you want the Z axis (tip) to lift while going through the Over Angle, you must
select 1. Otherwise: select 2.
The speed must be set in a previous memory address by registering a
Line
Speed
instruction using the
SETUP
key.
Dispense delay times used at the start of the circle and at the end of the circle can be
controlled by registering a
Line Dispense Setup
instruction in a previous memory
address. The
Line Dispense Setup
instruction is registered by pressing the
SETUP
key.
and
SECTION 5:2.2 Line Dispense Setup
.
The upward motion of the tip after dispensing can be controlled by registering a
Dispense
End Setup
instruction and / or a
Z Clearance
instruction in a previous memory address.
Dispense End Setup
and
Z Clearance
instructions are registered using the
SETUP
key.
SECTION 5:2.4 Dispense End Setup