Section 4: Programming Example
Part # 562187
Rev. E - Jan. 08
- Page 33 -
© 2008 I&J Fisnar Inc.
Instruction Display
Shows
9
Now jog the tip to the location of the third point
(
3: Arc Point
). When the location is correct,
press the
ENTER
key, then
5
to register the
location as an Arc point.
ADDR:5 PROG:10
EMPTY
10
Jog the tip to the location of the fourth point
(
4: Line Passing
). When the location is correct,
press the
ENTER
key, then
3
key to register the
location as a Line Passing point.
ADDR:6 PROG:10
EMPTY
11
Jog the tip to the location of the fifth point
(
5: Line Passing
). When the location is correct,
press the
ENTER
key, then
3
to register the
location as a Line Passing point.
ADDR:7 PROG:10
EMPTY
12
Jog the tip to the location of the sixth point
(
6: Line Passing
). When the location is correct,
press the
ENTER
key, then
3
to register the
location as a Line Passing point.
ADDR:8 PROG:10
EMPTY
13
Jog the tip to the location of the seventh point
(
7: Line End
). When the location is correct, press
the
ENTER
key, then
6
to register the location as
a Line End point.
ADDR:9 PROG:10
EMPTY
14
The line is now complete. The next step is to
register the dispense settings for the dots.
Press the
SETUP
key, then
3
to register the dot
dispensing time.
Point Dispense Setup
--------------------
Dis. Time:
Tail Time:
unit: sec
15
Type
0.5
to register a dispensing time of 0.5
seconds, then press
ENTER
.
Type
0.1
to register a waiting time after
dispensing of 0.1 seconds, then press
ENTER
.
ADDR:10 PROG:10
EMPTY
16
Jog the tip to the location of first dispense dot
(
8: Dispense Dot
). When the location is correct,
press the
ENTER
key, then
1
to register the
location as a Dispense Dot.
ADDR:11 PROG:10
EMPTY
17
Jog the tip to the location of second dispense dot
(
9: Dispense Dot
). When the location is correct,
press the
ENTER
key, then
1
to register the
location as a Dispense Dot.
ADDR:12 PROG:10
EMPTY
18
Jog the tip to the location of third dispense dot
(
10: Dispense Dot
). When the location is correct,
press the
ENTER
key, then
1
to register the
location as a Dispense Dot.
ADDR:13 PROG:10
EMPTY
19
The program is now complete.
Press
ENTER
, then
7
to register address 13 as
the END of the program.
ADDR:14 PROG:10
EMPTY
20
To run the program, press the
RUN
key..
Содержание I&J4000-LF Series