I&J4000-LF Series Operating Manual
Section 3: Teaching Overview
Part # 562187
Rev. E - Jan. 08
- Page 26 -
© 2008 I&J Fisnar Inc.
Function Description
Retract Setup
Registers Retract values at the current XYZ location.
Retract causes the tip to move up and back over the
dispensed bead after line dispensing.
Quickstep
Causes the robot to move very fast from one point to
another reducing the time of the dispensing cycle.
Auto Purge Setup
Automatically purges the system at the end of the
program.
ESTOP Output Status
After receiving the emergency stop signal, ESTOP
Output Status can modify the status of all the outputs or
leave them as before receiving the emergency signal.
Acceleration
Parameter that controls the robot’s acceleration
Pause Status
Sets the position to which the tip moves after pressing
the Start button. The tip can go to the Home position or
will stay at the position where the Start button was
pressed.
Language
Opens MENU for selecting the Language